{"id":{"repo_id":"unitec","oai_identifier":"oai:null:10652/2367"},"canonical_url":"https://search.ndltd.org/etd/unitec/oai:null:10652/2367","repository":{"repo_id":"unitec","name":"Unitec","base_url":"https://www.researchbank.ac.nz/server/oai/request"},"display":{"title":"Inter and intra-rater reliability of the manual assessment of respiratory motion ('MARM' technique) in adults","abstract":"AIM: The primary aim of this study was to investigate the inter- and intra-rater reliability of a \"manual assessment of breathing\" (MARM). A secondary aim was to explore the relationship between Breath Holding Time (BHT), Breathing Rate (BR), breathing compartment dominance (thoracic and abdominal), and two questionnaires concerned with symptoms of breathing (Nijmegen (NQ) and Self Evaluation of Breathing Questionnaires (SEBQ)). METHODS: Practitioners (n=6) received introductory level instruction in MARM assessment. They then rated the mechanical breathing pattern of 16 participants with nil to moderate breathing dysfunction. Participants completed two breathing questionnaires (NQ and SEBQ) and were also assessed for Breath Holding Time, Breathing Rate and Abdominal Excursion using Respiratory Inductive Plethysmography.RESULTS: The inter-rater and intra-rater reliability of the MARM was poor (inter-rater: ICC[2,1] range = -0.18 to 0.36; intra-rater: ICC[2,1] range = -0.51 to 0.92). Inter and intra-rater reliability of the MARM was insufficient to warrant clinical use. Moderate correlations were identified between Breathing Rate (BR) and Breath Holding Time (BHT) (r = 0.5; p = 0.04), between BHT and the Self Evaluation of Breathing Questionnaire (SEBQ) (r = 0.5; p = 0.05), and between the SEBQ and the Nijmegen Questionnaire (NQ) (r = 0.6; p = 0.01). CONCLUSIONS: Raters in this study demonstrated poor inter-rater reliability of the MARM. The intra-rater reliability is higher for some raters indicating that the MARM may be more useful for individual practice, when the same rater is undertaking assessment of breathing.","abstract_html":"AIM: The primary aim of this study was to investigate the inter- and intra-rater reliability of a &quot;manual assessment of breathing&quot; (MARM). A secondary aim was to explore the relationship between Breath Holding Time (BHT), Breathing Rate (BR), breathing compartment dominance (thoracic and abdominal), and two questionnaires concerned with symptoms of breathing (Nijmegen (NQ) and Self Evaluation of Breathing Questionnaires (SEBQ)). METHODS: Practitioners (n=6) received introductory level instruction in MARM assessment. They then rated the mechanical breathing pattern of 16 participants with nil to moderate breathing dysfunction. Participants completed two breathing questionnaires (NQ and SEBQ) and were also assessed for Breath Holding Time, Breathing Rate and Abdominal Excursion using Respiratory Inductive Plethysmography.RESULTS: The inter-rater and intra-rater reliability of the MARM was poor (inter-rater: ICC[2,1] range = -0.18 to 0.36; intra-rater: ICC[2,1] range = -0.51 to 0.92). Inter and intra-rater reliability of the MARM was insufficient to warrant clinical use. Moderate correlations were identified between Breathing Rate (BR) and Breath Holding Time (BHT) (r = 0.5; p = 0.04), between BHT and the Self Evaluation of Breathing Questionnaire (SEBQ) (r = 0.5; p = 0.05), and between the SEBQ and the Nijmegen Questionnaire (NQ) (r = 0.6; p = 0.01). CONCLUSIONS: Raters in this study demonstrated poor inter-rater reliability of the MARM. The intra-rater reliability is higher for some raters indicating that the MARM may be more useful for individual practice, when the same rater is undertaking assessment of breathing.","abstract_has_math":false,"creators":["Ludwig, Martin"],"institution":"Unitec Institute of Technology","degree_name":"Master of Osteopathy","degree_level":"Masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Moran, Robert","Bacon, Catherine"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-11-26T14:04:07Z","subjects":["breathing dysfunction","breathing assessment","respiration","measurement","physical examination"],"languages":["en"],"rights":["All rights reserved","Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Ludwig, M. (2013). Inter and intra-rater reliability of the manual assessment of respiratory motion (’MARM’ technique) in adults. (Unpublished document submitted in partial fulfilment of the requirements for the degree of Master of Osteopathy). Unitec Institute of Technology, Auckland, New Zealand. Retrieved from https://hdl.handle.net/10652/2367"],"render_values":[{"text":"Ludwig, M. (2013). Inter and intra-rater reliability of the manual assessment of respiratory motion (’MARM’ technique) in adults. (Unpublished document submitted in partial fulfilment of the requirements for the degree of Master of Osteopathy). Unitec Institute of Technology, Auckland, New Zealand. Retrieved from https://hdl.handle.net/10652/2367","href":null,"code":true}]},{"key":"dc:identifier.wikidata","label":"Dc Identifier Wikidata","values":["Q112900772"],"render_values":[{"text":"Q112900772","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10652/2367","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10652/2367","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aunitec%3Aoai%3Anull%3A10652%2F2367","prefix":"oai_dc"},"source_record":{"url":"https://www.researchbank.ac.nz/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Anull%3A10652%2F2367","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Moran, Robert","Bacon, Catherine"]},{"key":"dc:creator","label":"Author","values":["Ludwig, Martin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-02-06T22:22:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-02-06T22:22:51Z"]},{"key":"dc:date.issued","label":"Date","values":["2013"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Auckland, New Zealand"]},{"key":"dc:type","label":"Dc Type","values":["Masters Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Osteopathy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Unitec Institute of Technology"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["breathing dysfunction","breathing assessment","respiration","measurement","physical examination"]},{"key":"dc:subject.discipline","label":"Dc Subject Discipline","values":["Osteopathy"]},{"key":"dc:subject.marsden","label":"Dc Subject Marsden","values":["110203 Respiratory Diseases"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["All rights reserved"]},{"key":"dc:rights.holder","label":"Dc Rights Holder","values":["Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Ludwig, M. (2013). Inter and intra-rater reliability of the manual assessment of respiratory motion (’MARM’ technique) in adults. (Unpublished document submitted in partial fulfilment of the requirements for the degree of Master of Osteopathy). Unitec Institute of Technology, Auckland, New Zealand. Retrieved from https://hdl.handle.net/10652/2367"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10652/2367"]},{"key":"dc:identifier.wikidata","label":"Dc Identifier Wikidata","values":["Q112900772"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["AIM: The primary aim of this study was to investigate the inter- and intra-rater reliability of a \"manual assessment of breathing\" (MARM). A secondary aim was to explore the relationship between Breath Holding Time (BHT), Breathing Rate (BR), breathing compartment dominance (thoracic and abdominal), and two questionnaires concerned with symptoms of breathing (Nijmegen (NQ) and Self Evaluation of Breathing Questionnaires (SEBQ)). METHODS: Practitioners (n=6) received introductory level instruction in MARM assessment. They then rated the mechanical breathing pattern of 16 participants with nil to moderate breathing dysfunction. Participants completed two breathing questionnaires (NQ and SEBQ) and were also assessed for Breath Holding Time, Breathing Rate and Abdominal Excursion using Respiratory Inductive Plethysmography.RESULTS: The inter-rater and intra-rater reliability of the MARM was poor (inter-rater: ICC[2,1] range = -0.18 to 0.36; intra-rater: ICC[2,1] range = -0.51 to 0.92). Inter and intra-rater reliability of the MARM was insufficient to warrant clinical use. Moderate correlations were identified between Breathing Rate (BR) and Breath Holding Time (BHT) (r = 0.5; p = 0.04), between BHT and the Self Evaluation of Breathing Questionnaire (SEBQ) (r = 0.5; p = 0.05), and between the SEBQ and the Nijmegen Questionnaire (NQ) (r = 0.6; p = 0.01). CONCLUSIONS: Raters in this study demonstrated poor inter-rater reliability of the MARM. The intra-rater reliability is higher for some raters indicating that the MARM may be more useful for individual practice, when the same rater is undertaking assessment of breathing."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["69"]},{"key":"dc:title","label":"Title","values":["Inter and intra-rater reliability of the manual assessment of respiratory motion ('MARM' technique) in adults"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Unitec Institute of Technology"]}]}],"canonical_facts":{"dc:contributor.advisor":["Moran, Robert","Bacon, Catherine"],"dc:creator":["Ludwig, Martin"],"dc:date.accessioned":["2014-02-06T22:22:51Z"],"dc:date.available":["2014-02-06T22:22:51Z"],"dc:date.issued":["2013"],"dc:description.abstract":["AIM: The primary aim of this study was to investigate the inter- and intra-rater reliability of a \"manual assessment of breathing\" (MARM). A secondary aim was to explore the relationship between Breath Holding Time (BHT), Breathing Rate (BR), breathing compartment dominance (thoracic and abdominal), and two questionnaires concerned with symptoms of breathing (Nijmegen (NQ) and Self Evaluation of Breathing Questionnaires (SEBQ)). METHODS: Practitioners (n=6) received introductory level instruction in MARM assessment. They then rated the mechanical breathing pattern of 16 participants with nil to moderate breathing dysfunction. Participants completed two breathing questionnaires (NQ and SEBQ) and were also assessed for Breath Holding Time, Breathing Rate and Abdominal Excursion using Respiratory Inductive Plethysmography.RESULTS: The inter-rater and intra-rater reliability of the MARM was poor (inter-rater: ICC[2,1] range = -0.18 to 0.36; intra-rater: ICC[2,1] range = -0.51 to 0.92). Inter and intra-rater reliability of the MARM was insufficient to warrant clinical use. Moderate correlations were identified between Breathing Rate (BR) and Breath Holding Time (BHT) (r = 0.5; p = 0.04), between BHT and the Self Evaluation of Breathing Questionnaire (SEBQ) (r = 0.5; p = 0.05), and between the SEBQ and the Nijmegen Questionnaire (NQ) (r = 0.6; p = 0.01). CONCLUSIONS: Raters in this study demonstrated poor inter-rater reliability of the MARM. The intra-rater reliability is higher for some raters indicating that the MARM may be more useful for individual practice, when the same rater is undertaking assessment of breathing."],"dc:format.extent":["69"],"dc:identifier.citation":["Ludwig, M. (2013). Inter and intra-rater reliability of the manual assessment of respiratory motion (’MARM’ technique) in adults. (Unpublished document submitted in partial fulfilment of the requirements for the degree of Master of Osteopathy). Unitec Institute of Technology, Auckland, New Zealand. Retrieved from https://hdl.handle.net/10652/2367"],"dc:identifier.uri":["https://hdl.handle.net/10652/2367"],"dc:identifier.wikidata":["Q112900772"],"dc:language.iso":["en"],"dc:publisher.place":["Auckland, New Zealand"],"dc:rights":["All rights reserved"],"dc:rights.holder":["Author"],"dc:subject":["breathing dysfunction","breathing assessment","respiration","measurement","physical examination"],"dc:subject.discipline":["Osteopathy"],"dc:subject.marsden":["110203 Respiratory Diseases"],"dc:title":["Inter and intra-rater reliability of the manual assessment of respiratory motion ('MARM' technique) in adults"],"dc:type":["Masters Thesis"],"local:contributor.affiliation":["Unitec Institute of Technology"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Osteopathy"],"thesis:institution_name":["Unitec Institute of Technology"]},"updated_at":"2026-11-26T14:04:07Z"}