{"id":{"repo_id":"unitec","oai_identifier":"oai:null:10652/3485"},"canonical_url":"https://search.ndltd.org/etd/unitec/oai:null:10652/3485","repository":{"repo_id":"unitec","name":"Unitec","base_url":"https://www.researchbank.ac.nz/server/oai/request"},"display":{"title":"Reliability of deep cervical fascia and sternocleidomastoid thickness measurements using ultrasound imaging","abstract":"BACKGROUND: Recent literature has provided a hypothetical framework for the possible role of fascia within myofascial pain. This hypothesis involves structural alteration of deep cervical fascia within the loose connective tissue layer, as observed through ultrasound imaging (USI). This structural alteration has been termed ‘densification’, and has been associated with increased fascia thickness and reduced tissue compliance. Whilst increased cervical fascia thickness has been reported in one study to be significantly thicker within people with chronic neck pain compared to controls, a study assessing the reliability of cervical fascia measurements has not been conducted to date. OBJECTIVE: To investigate the reliability of deep cervical fascia and sternocleidomastoid thickness measurements utilising USI. METHODS: High-resolution, B-mode ultrasound was utilised to execute a standardised protocol for repeated thickness measurements of deep cervical fascia enveloping SCM muscle, and the SCM muscle itself. A convenience sample of 10 participants (5 males, 5 females, mean ± SD age = 26.2 ± 5.8 years, height 172.9 ± 13.2 cm, body mass 76.4 ± 16.6 kg, and median NDI score was 7% (range: 0 to 34 %) attended a single session. Intra-operator and inter-operator reliability was calculated for all thickness measurements obtained by a novice and an experienced USI operator. RESULTS: Both operators demonstrated ‘very high’ intra-operator and inter-operator reliability for SCM muscle thickness measurements (all ICCs >0.7). The experienced operator demonstrated ‘moderate’ reliability (ICC = 0.312; 95%CI 0.357 - 0.770) to ‘very high’ (ICC = 0.821; 95%CI 0.434 - 0.952) intra-operator reliability for cervical fascia measurements. The level of intra-operator reliability for the novice operator was inconsistent for both the SDF and DF measurements, ranging from ‘very low’ to ‘very high’. Inter-operator reliability for all fascia thickness measurements was ‘low’ (ICC = 0.033; 95%CI 0.581 - 0.623) to ‘moderate’ (ICC = 0.428; 95%CI 0.235 - 0.819). CONCLUSION: Within this study, the experienced operator demonstrated acceptable reliability for cervical fascia measurement with USI, whilst the novice operator was not reliable. Both the novice and experienced operators demonstrated high intra-operator and inter-operator reliability for SCM muscle thickness measurements.","abstract_html":"BACKGROUND: Recent literature has provided a hypothetical framework for the possible role of fascia within myofascial pain. This hypothesis involves structural alteration of deep cervical fascia within the loose connective tissue layer, as observed through ultrasound imaging (USI). This structural alteration has been termed ‘densification’, and has been associated with increased fascia thickness and reduced tissue compliance. Whilst increased cervical fascia thickness has been reported in one study to be significantly thicker within people with chronic neck pain compared to controls, a study assessing the reliability of cervical fascia measurements has not been conducted to date. OBJECTIVE: To investigate the reliability of deep cervical fascia and sternocleidomastoid thickness measurements utilising USI. METHODS: High-resolution, B-mode ultrasound was utilised to execute a standardised protocol for repeated thickness measurements of deep cervical fascia enveloping SCM muscle, and the SCM muscle itself. A convenience sample of 10 participants (5 males, 5 females, mean ± SD age = 26.2 ± 5.8 years, height 172.9 ± 13.2 cm, body mass 76.4 ± 16.6 kg, and median NDI score was 7% (range: 0 to 34 %) attended a single session. Intra-operator and inter-operator reliability was calculated for all thickness measurements obtained by a novice and an experienced USI operator. RESULTS: Both operators demonstrated ‘very high’ intra-operator and inter-operator reliability for SCM muscle thickness measurements (all ICCs &gt;0.7). The experienced operator demonstrated ‘moderate’ reliability (ICC = 0.312; 95%CI 0.357 - 0.770) to ‘very high’ (ICC = 0.821; 95%CI 0.434 - 0.952) intra-operator reliability for cervical fascia measurements. The level of intra-operator reliability for the novice operator was inconsistent for both the SDF and DF measurements, ranging from ‘very low’ to ‘very high’. Inter-operator reliability for all fascia thickness measurements was ‘low’ (ICC = 0.033; 95%CI 0.581 - 0.623) to ‘moderate’ (ICC = 0.428; 95%CI 0.235 - 0.819). CONCLUSION: Within this study, the experienced operator demonstrated acceptable reliability for cervical fascia measurement with USI, whilst the novice operator was not reliable. Both the novice and experienced operators demonstrated high intra-operator and inter-operator reliability for SCM muscle thickness measurements.","abstract_has_math":false,"creators":["Harley, Jude James"],"institution":"Unitec Institute of Technology","degree_name":"Master of Osteopathy","degree_level":"Masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Moran, Robert"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-02-03","date_published":"2016-02-03","updated_at":"2026-11-26T14:04:18Z","subjects":["neck pain","chronic pain","deep cervical fascia","cervical fascia","ultrasound imaging (USI)","fascia","reliability","test-restest","interoperability"],"languages":["en"],"rights":["All rights reserved","Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Harley, J. J. (2016). Reliability of deep cervical fascia and sternocleidomastoid thickness measurements using ultrasound imaging. An unpublished thesis submitted in partial fulfilment for the requirements for the Unitec degree of Master of Osteopathy, Unitec Institute of Technology, New Zealand."],"render_values":[{"text":"Harley, J. J. (2016). Reliability of deep cervical fascia and sternocleidomastoid thickness measurements using ultrasound imaging. An unpublished thesis submitted in partial fulfilment for the requirements for the Unitec degree of Master of Osteopathy, Unitec Institute of Technology, New Zealand.","href":null,"code":true}]},{"key":"dc:identifier.wikidata","label":"Dc Identifier Wikidata","values":["Q112924869"],"render_values":[{"text":"Q112924869","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10652/3485","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10652/3485","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aunitec%3Aoai%3Anull%3A10652%2F3485","prefix":"oai_dc"},"source_record":{"url":"https://www.researchbank.ac.nz/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Anull%3A10652%2F3485","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Moran, Robert"]},{"key":"dc:creator","label":"Author","values":["Harley, Jude James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-07-17T21:12:40Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-07-17T21:12:40Z"]},{"key":"dc:date.issued","label":"Date","values":["2016-02-03"]},{"key":"dc:type","label":"Dc Type","values":["Masters Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Osteopathy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Unitec Institute of Technology"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["neck pain","chronic pain","deep cervical fascia","cervical fascia","ultrasound imaging (USI)","fascia","reliability","test-restest","interoperability"]},{"key":"dc:subject.discipline","label":"Dc Subject Discipline","values":["Osteopathy"]},{"key":"dc:subject.marsden","label":"Dc Subject Marsden","values":["110320 Radiology and Organ Imaging","110499 Complementary and Alternative Medicine not elsewhere classified"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["All rights reserved"]},{"key":"dc:rights.holder","label":"Dc Rights Holder","values":["Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Harley, J. J. (2016). Reliability of deep cervical fascia and sternocleidomastoid thickness measurements using ultrasound imaging. An unpublished thesis submitted in partial fulfilment for the requirements for the Unitec degree of Master of Osteopathy, Unitec Institute of Technology, New Zealand."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10652/3485"]},{"key":"dc:identifier.wikidata","label":"Dc Identifier Wikidata","values":["Q112924869"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["BACKGROUND: Recent literature has provided a hypothetical framework for the possible role of fascia within myofascial pain. This hypothesis involves structural alteration of deep cervical fascia within the loose connective tissue layer, as observed through ultrasound imaging (USI). This structural alteration has been termed ‘densification’, and has been associated with increased fascia thickness and reduced tissue compliance. Whilst increased cervical fascia thickness has been reported in one study to be significantly thicker within people with chronic neck pain compared to controls, a study assessing the reliability of cervical fascia measurements has not been conducted to date. OBJECTIVE: To investigate the reliability of deep cervical fascia and sternocleidomastoid thickness measurements utilising USI. METHODS: High-resolution, B-mode ultrasound was utilised to execute a standardised protocol for repeated thickness measurements of deep cervical fascia enveloping SCM muscle, and the SCM muscle itself. A convenience sample of 10 participants (5 males, 5 females, mean ± SD age = 26.2 ± 5.8 years, height 172.9 ± 13.2 cm, body mass 76.4 ± 16.6 kg, and median NDI score was 7% (range: 0 to 34 %) attended a single session. Intra-operator and inter-operator reliability was calculated for all thickness measurements obtained by a novice and an experienced USI operator. RESULTS: Both operators demonstrated ‘very high’ intra-operator and inter-operator reliability for SCM muscle thickness measurements (all ICCs >0.7). The experienced operator demonstrated ‘moderate’ reliability (ICC = 0.312; 95%CI 0.357 - 0.770) to ‘very high’ (ICC = 0.821; 95%CI 0.434 - 0.952) intra-operator reliability for cervical fascia measurements. The level of intra-operator reliability for the novice operator was inconsistent for both the SDF and DF measurements, ranging from ‘very low’ to ‘very high’. Inter-operator reliability for all fascia thickness measurements was ‘low’ (ICC = 0.033; 95%CI 0.581 - 0.623) to ‘moderate’ (ICC = 0.428; 95%CI 0.235 - 0.819). CONCLUSION: Within this study, the experienced operator demonstrated acceptable reliability for cervical fascia measurement with USI, whilst the novice operator was not reliable. Both the novice and experienced operators demonstrated high intra-operator and inter-operator reliability for SCM muscle thickness measurements."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["88"]},{"key":"dc:title","label":"Title","values":["Reliability of deep cervical fascia and sternocleidomastoid thickness measurements using ultrasound imaging"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Unitec Institute of Technology","Unitec Institutte of Technology"]}]}],"canonical_facts":{"dc:contributor.advisor":["Moran, Robert"],"dc:creator":["Harley, Jude James"],"dc:date.accessioned":["2016-07-17T21:12:40Z"],"dc:date.available":["2016-07-17T21:12:40Z"],"dc:date.issued":["2016-02-03"],"dc:description.abstract":["BACKGROUND: Recent literature has provided a hypothetical framework for the possible role of fascia within myofascial pain. This hypothesis involves structural alteration of deep cervical fascia within the loose connective tissue layer, as observed through ultrasound imaging (USI). This structural alteration has been termed ‘densification’, and has been associated with increased fascia thickness and reduced tissue compliance. Whilst increased cervical fascia thickness has been reported in one study to be significantly thicker within people with chronic neck pain compared to controls, a study assessing the reliability of cervical fascia measurements has not been conducted to date. OBJECTIVE: To investigate the reliability of deep cervical fascia and sternocleidomastoid thickness measurements utilising USI. METHODS: High-resolution, B-mode ultrasound was utilised to execute a standardised protocol for repeated thickness measurements of deep cervical fascia enveloping SCM muscle, and the SCM muscle itself. A convenience sample of 10 participants (5 males, 5 females, mean ± SD age = 26.2 ± 5.8 years, height 172.9 ± 13.2 cm, body mass 76.4 ± 16.6 kg, and median NDI score was 7% (range: 0 to 34 %) attended a single session. Intra-operator and inter-operator reliability was calculated for all thickness measurements obtained by a novice and an experienced USI operator. RESULTS: Both operators demonstrated ‘very high’ intra-operator and inter-operator reliability for SCM muscle thickness measurements (all ICCs >0.7). The experienced operator demonstrated ‘moderate’ reliability (ICC = 0.312; 95%CI 0.357 - 0.770) to ‘very high’ (ICC = 0.821; 95%CI 0.434 - 0.952) intra-operator reliability for cervical fascia measurements. The level of intra-operator reliability for the novice operator was inconsistent for both the SDF and DF measurements, ranging from ‘very low’ to ‘very high’. Inter-operator reliability for all fascia thickness measurements was ‘low’ (ICC = 0.033; 95%CI 0.581 - 0.623) to ‘moderate’ (ICC = 0.428; 95%CI 0.235 - 0.819). CONCLUSION: Within this study, the experienced operator demonstrated acceptable reliability for cervical fascia measurement with USI, whilst the novice operator was not reliable. Both the novice and experienced operators demonstrated high intra-operator and inter-operator reliability for SCM muscle thickness measurements."],"dc:format.extent":["88"],"dc:identifier.citation":["Harley, J. J. (2016). Reliability of deep cervical fascia and sternocleidomastoid thickness measurements using ultrasound imaging. An unpublished thesis submitted in partial fulfilment for the requirements for the Unitec degree of Master of Osteopathy, Unitec Institute of Technology, New Zealand."],"dc:identifier.uri":["https://hdl.handle.net/10652/3485"],"dc:identifier.wikidata":["Q112924869"],"dc:language.iso":["en"],"dc:rights":["All rights reserved"],"dc:rights.holder":["Author"],"dc:subject":["neck pain","chronic pain","deep cervical fascia","cervical fascia","ultrasound imaging (USI)","fascia","reliability","test-restest","interoperability"],"dc:subject.discipline":["Osteopathy"],"dc:subject.marsden":["110320 Radiology and Organ Imaging","110499 Complementary and Alternative Medicine not elsewhere classified"],"dc:title":["Reliability of deep cervical fascia and sternocleidomastoid thickness measurements using ultrasound imaging"],"dc:type":["Masters Thesis"],"local:contributor.affiliation":["Unitec Institute of Technology","Unitec Institutte of Technology"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Osteopathy"],"thesis:institution_name":["Unitec Institute of Technology"]},"updated_at":"2026-11-26T14:04:18Z"}