{"id":{"repo_id":"unitec","oai_identifier":"oai:null:10652/3506"},"canonical_url":"https://search.ndltd.org/etd/unitec/oai:null:10652/3506","repository":{"repo_id":"unitec","name":"Unitec","base_url":"https://www.researchbank.ac.nz/server/oai/request"},"display":{"title":"Inter and intra-examiner reliability of ultrasound elastography for assessment of the anterior thigh in healthy adults","abstract":"BACKGROUND: To date there are few studies of acceptable methodological quality investigating the reliability of elastography ultrasound use in the lower limb. The aim of the study was to investigate the inter and intra-reliability of EUS assessment of anterior thigh soft-tissues. METHODS: Twelve healthy subjects (9 females, 3 males, mean ± SD age=28.9 ± 5.8 years, height = 169.6 ± 9.2cm, weight 69.6 ± 13.4kg) were recruited using convenience sampling. A repeated measures test retest design was used to compare EUS measures between (inter) and within (intra) 3 examiners (2 novices, 1 expert) using acoustic radiation force impulse elastography. The subjects attended one session where each examiner collected measures from each subject two times. Colour hue histograms were derived from elastogram images. RESULTS: Extraction reliability for images was excellent with ICC of 0.99 (95% CI= 0.99 – 1.00). The intra-examiner reliability was ‘fair to good’ for the experienced examiner and mostly ‘excellent’ for the novices. The inter-examiner reliability ranged between ‘fair to good’ and ‘excellent’. CONCLUSIONS: There was acceptable reliability for both inter and intra-examiner reliability for EUS assessment of anterior thigh soft-tissue stiffness. However, the small number of examiners may limit the generalisability of these findings.","abstract_html":"BACKGROUND: To date there are few studies of acceptable methodological quality investigating the reliability of elastography ultrasound use in the lower limb. The aim of the study was to investigate the inter and intra-reliability of EUS assessment of anterior thigh soft-tissues. METHODS: Twelve healthy subjects (9 females, 3 males, mean ± SD age=28.9 ± 5.8 years, height = 169.6 ± 9.2cm, weight 69.6 ± 13.4kg) were recruited using convenience sampling. A repeated measures test retest design was used to compare EUS measures between (inter) and within (intra) 3 examiners (2 novices, 1 expert) using acoustic radiation force impulse elastography. The subjects attended one session where each examiner collected measures from each subject two times. Colour hue histograms were derived from elastogram images. RESULTS: Extraction reliability for images was excellent with ICC of 0.99 (95% CI= 0.99 – 1.00). The intra-examiner reliability was ‘fair to good’ for the experienced examiner and mostly ‘excellent’ for the novices. The inter-examiner reliability ranged between ‘fair to good’ and ‘excellent’. CONCLUSIONS: There was acceptable reliability for both inter and intra-examiner reliability for EUS assessment of anterior thigh soft-tissue stiffness. However, the small number of examiners may limit the generalisability of these findings.","abstract_has_math":false,"creators":["Sharma, Avish"],"institution":"Unitec Institute of Technology","degree_name":"Master of Osteopathy","degree_level":"Masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Moran, Robert"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-26T14:04:18Z","subjects":["elasticity imaging technique","reliability","ultrasound elastography","quadriceps","acoustic radiation force impulse (ARFI) imaging"],"languages":["en"],"rights":["All rights reserved","Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Sharma, A. (2016). Inter and intra-examiner reliability of ultrasound elastography for assessment of the anterior thigh in healthy adults. An unpublished thesis is submitted in partial fulfillment for the requirements for the degree of Master of Osteopathy, Unitec Institute of Technology, New Zealand."],"render_values":[{"text":"Sharma, A. (2016). Inter and intra-examiner reliability of ultrasound elastography for assessment of the anterior thigh in healthy adults. An unpublished thesis is submitted in partial fulfillment for the requirements for the degree of Master of Osteopathy, Unitec Institute of Technology, New Zealand.","href":null,"code":true}]},{"key":"dc:identifier.wikidata","label":"Dc Identifier Wikidata","values":["Q112926463"],"render_values":[{"text":"Q112926463","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10652/3506","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10652/3506","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aunitec%3Aoai%3Anull%3A10652%2F3506","prefix":"oai_dc"},"source_record":{"url":"https://www.researchbank.ac.nz/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Anull%3A10652%2F3506","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Moran, Robert"]},{"key":"dc:creator","label":"Author","values":["Sharma, Avish"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-08-01T21:26:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-08-01T21:26:46Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:type","label":"Dc Type","values":["Masters Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Osteopathy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Unitec Institute of Technology"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["elasticity imaging technique","reliability","ultrasound elastography","quadriceps","acoustic radiation force impulse (ARFI) imaging"]},{"key":"dc:subject.discipline","label":"Dc Subject Discipline","values":["Osteopathy"]},{"key":"dc:subject.marsden","label":"Dc Subject Marsden","values":["110499 Complementary and Alternative Medicine not elsewhere classified"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["All rights reserved"]},{"key":"dc:rights.holder","label":"Dc Rights Holder","values":["Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Sharma, A. (2016). Inter and intra-examiner reliability of ultrasound elastography for assessment of the anterior thigh in healthy adults. An unpublished thesis is submitted in partial fulfillment for the requirements for the degree of Master of Osteopathy, Unitec Institute of Technology, New Zealand."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10652/3506"]},{"key":"dc:identifier.wikidata","label":"Dc Identifier Wikidata","values":["Q112926463"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["BACKGROUND: To date there are few studies of acceptable methodological quality investigating the reliability of elastography ultrasound use in the lower limb. The aim of the study was to investigate the inter and intra-reliability of EUS assessment of anterior thigh soft-tissues. METHODS: Twelve healthy subjects (9 females, 3 males, mean ± SD age=28.9 ± 5.8 years, height = 169.6 ± 9.2cm, weight 69.6 ± 13.4kg) were recruited using convenience sampling. A repeated measures test retest design was used to compare EUS measures between (inter) and within (intra) 3 examiners (2 novices, 1 expert) using acoustic radiation force impulse elastography. The subjects attended one session where each examiner collected measures from each subject two times. Colour hue histograms were derived from elastogram images. RESULTS: Extraction reliability for images was excellent with ICC of 0.99 (95% CI= 0.99 – 1.00). The intra-examiner reliability was ‘fair to good’ for the experienced examiner and mostly ‘excellent’ for the novices. The inter-examiner reliability ranged between ‘fair to good’ and ‘excellent’. CONCLUSIONS: There was acceptable reliability for both inter and intra-examiner reliability for EUS assessment of anterior thigh soft-tissue stiffness. However, the small number of examiners may limit the generalisability of these findings."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["80"]},{"key":"dc:title","label":"Title","values":["Inter and intra-examiner reliability of ultrasound elastography for assessment of the anterior thigh in healthy adults"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Unitec Institute of Technology"]}]}],"canonical_facts":{"dc:contributor.advisor":["Moran, Robert"],"dc:creator":["Sharma, Avish"],"dc:date.accessioned":["2016-08-01T21:26:46Z"],"dc:date.available":["2016-08-01T21:26:46Z"],"dc:date.issued":["2016"],"dc:description.abstract":["BACKGROUND: To date there are few studies of acceptable methodological quality investigating the reliability of elastography ultrasound use in the lower limb. The aim of the study was to investigate the inter and intra-reliability of EUS assessment of anterior thigh soft-tissues. METHODS: Twelve healthy subjects (9 females, 3 males, mean ± SD age=28.9 ± 5.8 years, height = 169.6 ± 9.2cm, weight 69.6 ± 13.4kg) were recruited using convenience sampling. A repeated measures test retest design was used to compare EUS measures between (inter) and within (intra) 3 examiners (2 novices, 1 expert) using acoustic radiation force impulse elastography. The subjects attended one session where each examiner collected measures from each subject two times. Colour hue histograms were derived from elastogram images. RESULTS: Extraction reliability for images was excellent with ICC of 0.99 (95% CI= 0.99 – 1.00). The intra-examiner reliability was ‘fair to good’ for the experienced examiner and mostly ‘excellent’ for the novices. The inter-examiner reliability ranged between ‘fair to good’ and ‘excellent’. CONCLUSIONS: There was acceptable reliability for both inter and intra-examiner reliability for EUS assessment of anterior thigh soft-tissue stiffness. However, the small number of examiners may limit the generalisability of these findings."],"dc:format.extent":["80"],"dc:identifier.citation":["Sharma, A. (2016). Inter and intra-examiner reliability of ultrasound elastography for assessment of the anterior thigh in healthy adults. An unpublished thesis is submitted in partial fulfillment for the requirements for the degree of Master of Osteopathy, Unitec Institute of Technology, New Zealand."],"dc:identifier.uri":["https://hdl.handle.net/10652/3506"],"dc:identifier.wikidata":["Q112926463"],"dc:language.iso":["en"],"dc:rights":["All rights reserved"],"dc:rights.holder":["Author"],"dc:subject":["elasticity imaging technique","reliability","ultrasound elastography","quadriceps","acoustic radiation force impulse (ARFI) imaging"],"dc:subject.discipline":["Osteopathy"],"dc:subject.marsden":["110499 Complementary and Alternative Medicine not elsewhere classified"],"dc:title":["Inter and intra-examiner reliability of ultrasound elastography for assessment of the anterior thigh in healthy adults"],"dc:type":["Masters Thesis"],"local:contributor.affiliation":["Unitec Institute of Technology"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Osteopathy"],"thesis:institution_name":["Unitec Institute of Technology"]},"updated_at":"2026-11-26T14:04:18Z"}