{"id":{"repo_id":"unr","oai_identifier":"oai:null:11714/2687"},"canonical_url":"https://search.ndltd.org/etd/unr/oai:null:11714/2687","repository":{"repo_id":"unr","name":"University of Nevada - Reno","base_url":"https://scholarwolf.unr.edu/server/oai/request"},"display":{"title":"Development of Mobile Solar Evaluation Laboratory & Technical and Economic Performance of the Goldade Site-Built Air Collector","abstract":"The Great Basin climate type is ideal for the utilization of solar winter space heat from air collectors; perhaps the most economically viable option for solar space heating is that of site built air collectors (SBAC). Unfortunately SBACs are a rarely utilized technology primarily because there is presently no standard method to test these types of collectors. This thesis provides a viable testing method for SBACs and the theoretical calculations required to develop testing and provide ratings based on industry standards. This leads to development of the Mobile Solar Evaluation Laboratory (MSEL).The Goldade Family built a 128 ft2 solar air heater for winter space heating, and the MSEL was employed to evaluate the technical and economic performance of that system. Theory and field testing correlated well, and it was proven that the MSEL accurately predicts SBAC performance. In most Northern Nevada households solar space heating can be cost effective. Solar space heating also reduces substantial CO2 from being added to the atmosphere.","abstract_html":"The Great Basin climate type is ideal for the utilization of solar winter space heat from air collectors; perhaps the most economically viable option for solar space heating is that of site built air collectors (SBAC). Unfortunately SBACs are a rarely utilized technology primarily because there is presently no standard method to test these types of collectors. This thesis provides a viable testing method for SBACs and the theoretical calculations required to develop testing and provide ratings based on industry standards. This leads to development of the Mobile Solar Evaluation Laboratory (MSEL).The Goldade Family built a 128 ft2 solar air heater for winter space heating, and the MSEL was employed to evaluate the technical and economic performance of that system. Theory and field testing correlated well, and it was proven that the MSEL accurately predicts SBAC performance. In most Northern Nevada households solar space heating can be cost effective. Solar space heating also reduces substantial CO2 from being added to the atmosphere.","abstract_has_math":false,"creators":["Goldade, Travis"],"institution":null,"degree_name":null,"degree_level":"Master's Degree","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Evrensel, Cahit A."],"committee_chairs":[],"committee_members":["Turner, Robert H.","Hoekman, Kent S."],"year":2015,"date_issued":"2015","date_published":"2015","updated_at":"2026-11-19T09:50:36Z","subjects":["Air Collector","Economics","Renewable Energy","Solar","Space Heat"],"languages":[],"rights":["In Copyright(All Rights Reserved)","Author(s)"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11714/2687","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11714/2687","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarwolf.unr.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Anull%3A11714%2F2687","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Evrensel, Cahit A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Turner, Robert H.","Hoekman, Kent S."]},{"key":"dc:creator","label":"Author","values":["Goldade, Travis"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-02-12T19:05:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-02-12T19:05:30Z"]},{"key":"dc:date.issued","label":"Date","values":["2015"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2015-01-01"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2017-11-03T12:22:23Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's Degree"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Air Collector","Economics","Renewable Energy","Solar","Space Heat"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright(All Rights Reserved)"]},{"key":"dc:rights.holder","label":"Dc Rights Holder","values":["Author(s)"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11714/2687"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Great Basin climate type is ideal for the utilization of solar winter space heat from air collectors; perhaps the most economically viable option for solar space heating is that of site built air collectors (SBAC). Unfortunately SBACs are a rarely utilized technology primarily because there is presently no standard method to test these types of collectors. This thesis provides a viable testing method for SBACs and the theoretical calculations required to develop testing and provide ratings based on industry standards. This leads to development of the Mobile Solar Evaluation Laboratory (MSEL).The Goldade Family built a 128 ft2 solar air heater for winter space heating, and the MSEL was employed to evaluate the technical and economic performance of that system. Theory and field testing correlated well, and it was proven that the MSEL accurately predicts SBAC performance. In most Northern Nevada households solar space heating can be cost effective. Solar space heating also reduces substantial CO2 from being added to the atmosphere."]},{"key":"dc:format","label":"Dc Format","values":["PDF"]},{"key":"dc:title","label":"Title","values":["Development of Mobile Solar Evaluation Laboratory & Technical and Economic Performance of the Goldade Site-Built Air Collector"]}]}],"canonical_facts":{"dc:contributor.advisor":["Evrensel, Cahit A."],"dc:contributor.committeemember":["Turner, Robert H.","Hoekman, Kent S."],"dc:creator":["Goldade, Travis"],"dc:date.accessioned":["2018-02-12T19:05:30Z"],"dc:date.available":["2018-02-12T19:05:30Z"],"dc:date.issued":["2015"],"dc:date.submitted":["2015-01-01"],"dc:date.updated":["2017-11-03T12:22:23Z"],"dc:description.abstract":["The Great Basin climate type is ideal for the utilization of solar winter space heat from air collectors; perhaps the most economically viable option for solar space heating is that of site built air collectors (SBAC). Unfortunately SBACs are a rarely utilized technology primarily because there is presently no standard method to test these types of collectors. This thesis provides a viable testing method for SBACs and the theoretical calculations required to develop testing and provide ratings based on industry standards. This leads to development of the Mobile Solar Evaluation Laboratory (MSEL).The Goldade Family built a 128 ft2 solar air heater for winter space heating, and the MSEL was employed to evaluate the technical and economic performance of that system. Theory and field testing correlated well, and it was proven that the MSEL accurately predicts SBAC performance. In most Northern Nevada households solar space heating can be cost effective. Solar space heating also reduces substantial CO2 from being added to the atmosphere."],"dc:format":["PDF"],"dc:identifier.uri":["http://hdl.handle.net/11714/2687"],"dc:rights":["In Copyright(All Rights Reserved)"],"dc:rights.holder":["Author(s)"],"dc:subject":["Air Collector","Economics","Renewable Energy","Solar","Space Heat"],"dc:title":["Development of Mobile Solar Evaluation Laboratory & Technical and Economic Performance of the Goldade Site-Built Air Collector"],"dc:type":["Thesis"],"thesis:degree_department":["Mechanical Engineering"],"thesis:degree_level":["Master's Degree"]},"updated_at":"2026-11-19T09:50:36Z"}