{"id":{"repo_id":"unr","oai_identifier":"oai:null:11714/361"},"canonical_url":"https://search.ndltd.org/etd/unr/oai:null:11714/361","repository":{"repo_id":"unr","name":"University of Nevada - Reno","base_url":"https://scholarwolf.unr.edu/server/oai/request"},"display":{"title":"Comparison of Tissue Contractile Responses of Rat Models of Pulmonary Artery Hypertension and Type I/II Diabetes","abstract":"Protein purification processes have become highly sophisticated in recent decades. Even the simplest separations require various steps to ensure the highest possible purity and maximum profit. The goal of this paper is to propose a configuration of unit operations that will purify a monoclonal antibody (Lucentis) grown and extracted from e. coli for the purpose of treating the \"wet\" form of macular degeneration. The following units will be explored, in this determined order: homogenizer, centrifuge, column chromatography, tangential flow filtration. Specifications for these units will be determined using data from either literature research or experimentation. A sample of bacteria culture that has been processed through a homogenizer and centrifuge were obtained and used in our experimentations. A homogenizer is used to break apart the cell wall to release the proteins inside. A centrifuge is used to do a crude mass separation before more intrinsic steps to isolate the desired antibody are needed. Specifications for these two units such as reactor size and flow area will be theorized. Two types of column chromatography will be used to separate and purify the sample: cation exchange and mixed (hydrophobic interactionanion exchange) mode. The resin height, column height, and column diameter will be determined for these units. Chromatography is commonly used to isolate and purify proteins. A tangential flow filtration is then used to remove any excess debris from the sample as the last purification procedure. The culmination of these units proposes a purification process that can ideally isolate a desired antibody and produce a pure product, ready for human use.","abstract_html":"Protein purification processes have become highly sophisticated in recent decades. Even the simplest separations require various steps to ensure the highest possible purity and maximum profit. The goal of this paper is to propose a configuration of unit operations that will purify a monoclonal antibody (Lucentis) grown and extracted from e. coli for the purpose of treating the &quot;wet&quot; form of macular degeneration. The following units will be explored, in this determined order: homogenizer, centrifuge, column chromatography, tangential flow filtration. Specifications for these units will be determined using data from either literature research or experimentation. A sample of bacteria culture that has been processed through a homogenizer and centrifuge were obtained and used in our experimentations. A homogenizer is used to break apart the cell wall to release the proteins inside. A centrifuge is used to do a crude mass separation before more intrinsic steps to isolate the desired antibody are needed. Specifications for these two units such as reactor size and flow area will be theorized. Two types of column chromatography will be used to separate and purify the sample: cation exchange and mixed (hydrophobic interactionanion exchange) mode. The resin height, column height, and column diameter will be determined for these units. Chromatography is commonly used to isolate and purify proteins. A tangential flow filtration is then used to remove any excess debris from the sample as the last purification procedure. The culmination of these units proposes a purification process that can ideally isolate a desired antibody and produce a pure product, ready for human use.","abstract_has_math":false,"creators":["Islam, Schinria R.","Bridges, Fredy","Laxa, Madeline","McKenna, Becky","Pugh, Shawn"],"institution":"University of Nevada, Reno","degree_name":"Chemical Engineering","degree_level":"Honors Thesis","degree_discipline":null,"degree_department":"Chemical and Materials Engineering","school":null,"contributors":[],"advisors":["Leblanc, Normand"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-11-19T09:52:08Z","subjects":[],"languages":["en_US"],"rights":["In Copyright(All Rights Reserved)","Author(s)"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11714/361","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11714/361","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarwolf.unr.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Anull%3A11714%2F361","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Leblanc, Normand"]},{"key":"dc:creator","label":"Author","values":["Islam, Schinria R.","Bridges, Fredy","Laxa, Madeline","McKenna, Becky","Pugh, Shawn"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-01-24T23:08:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-01-24T23:08:49Z"]},{"key":"dc:date.issued","label":"Date","values":["2010"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Chemical and Materials Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Honors Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Chemical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Nevada, Reno"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright(All Rights Reserved)"]},{"key":"dc:rights.holder","label":"Dc Rights Holder","values":["Author(s)"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11714/361"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The University of Nevada, Reno Libraries will promptly respond to removal requests related to content that violates intellectual property laws, data protections, or has been uploaded without creator consent. Takedown notices should be directed to our ScholarWolf team (scholarwolf@library.unr.edu) with information about the object, including its full URL and the nature of your complaint."]},{"key":"dc:description.abstract","label":"Abstract","values":["Protein purification processes have become highly sophisticated in recent decades. Even the simplest separations require various steps to ensure the highest possible purity and maximum profit. The goal of this paper is to propose a configuration of unit operations that will purify a monoclonal antibody (Lucentis) grown and extracted from e. coli for the purpose of treating the \"wet\" form of macular degeneration. The following units will be explored, in this determined order: homogenizer, centrifuge, column chromatography, tangential flow filtration. Specifications for these units will be determined using data from either literature research or experimentation. A sample of bacteria culture that has been processed through a homogenizer and centrifuge were obtained and used in our experimentations. A homogenizer is used to break apart the cell wall to release the proteins inside. A centrifuge is used to do a crude mass separation before more intrinsic steps to isolate the desired antibody are needed. Specifications for these two units such as reactor size and flow area will be theorized. Two types of column chromatography will be used to separate and purify the sample: cation exchange and mixed (hydrophobic interactionanion exchange) mode. The resin height, column height, and column diameter will be determined for these units. Chromatography is commonly used to isolate and purify proteins. A tangential flow filtration is then used to remove any excess debris from the sample as the last purification procedure. The culmination of these units proposes a purification process that can ideally isolate a desired antibody and produce a pure product, ready for human use."]},{"key":"dc:format","label":"Dc Format","values":["PDF"]},{"key":"dc:title","label":"Title","values":["Comparison of Tissue Contractile Responses of Rat Models of Pulmonary Artery Hypertension and Type I/II Diabetes"]}]}],"canonical_facts":{"dc:contributor.advisor":["Leblanc, Normand"],"dc:creator":["Islam, Schinria R.","Bridges, Fredy","Laxa, Madeline","McKenna, Becky","Pugh, Shawn"],"dc:date.accessioned":["2017-01-24T23:08:49Z"],"dc:date.available":["2017-01-24T23:08:49Z"],"dc:date.issued":["2010"],"dc:description":["The University of Nevada, Reno Libraries will promptly respond to removal requests related to content that violates intellectual property laws, data protections, or has been uploaded without creator consent. Takedown notices should be directed to our ScholarWolf team (scholarwolf@library.unr.edu) with information about the object, including its full URL and the nature of your complaint."],"dc:description.abstract":["Protein purification processes have become highly sophisticated in recent decades. Even the simplest separations require various steps to ensure the highest possible purity and maximum profit. The goal of this paper is to propose a configuration of unit operations that will purify a monoclonal antibody (Lucentis) grown and extracted from e. coli for the purpose of treating the \"wet\" form of macular degeneration. The following units will be explored, in this determined order: homogenizer, centrifuge, column chromatography, tangential flow filtration. Specifications for these units will be determined using data from either literature research or experimentation. A sample of bacteria culture that has been processed through a homogenizer and centrifuge were obtained and used in our experimentations. A homogenizer is used to break apart the cell wall to release the proteins inside. A centrifuge is used to do a crude mass separation before more intrinsic steps to isolate the desired antibody are needed. Specifications for these two units such as reactor size and flow area will be theorized. Two types of column chromatography will be used to separate and purify the sample: cation exchange and mixed (hydrophobic interactionanion exchange) mode. The resin height, column height, and column diameter will be determined for these units. Chromatography is commonly used to isolate and purify proteins. A tangential flow filtration is then used to remove any excess debris from the sample as the last purification procedure. The culmination of these units proposes a purification process that can ideally isolate a desired antibody and produce a pure product, ready for human use."],"dc:format":["PDF"],"dc:identifier.uri":["http://hdl.handle.net/11714/361"],"dc:language.iso":["en_US"],"dc:rights":["In Copyright(All Rights Reserved)"],"dc:rights.holder":["Author(s)"],"dc:title":["Comparison of Tissue Contractile Responses of Rat Models of Pulmonary Artery Hypertension and Type I/II Diabetes"],"dc:type":["Thesis"],"thesis:degree_department":["Chemical and Materials Engineering"],"thesis:degree_level":["Honors Thesis"],"thesis:degree_name":["Chemical Engineering"],"thesis:institution_name":["University of Nevada, Reno"]},"updated_at":"2026-11-19T09:52:08Z"}