{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc103281"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc103281","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Dynamic Measurement of Intraoral Pressure and Sound Pressure With Laryngoscopic Characterization During Oboe Performance","abstract":"Measurements of intraoral pressure (IOP) and sound pressure level (SPL) were taken of four oboists as they performed two sets of musical exercises: (1) crescendo-decrescendo from pp to ff and back to pp on the pitches D4, G4, C5 and A5, and (2) straight and vibrato performances of the same four pitches at mf. Video images of the vocal tract were also made using flexible fiberoptic nasoendoscopy (FFN). IOP and SPL data were captured in real time by the WinDaq®/Lite software package, with the dB meter located 8-9 inches in directly front of the oboe bell. The study yielded minimum and maximum values from 21.04 to 57.81 mm Hg and from 65.53 to 100.89 dB across all pitches examined. Discussion is included for the following topics: (1) the oboe’s sound envelope, or functional range of IOP and SPL values at different pitch levels, including the nonlinearity in the relationship between IOP and SPL on the oboe, (2) the static activation and kinetic maintenance thresholds for reed vibration, (3) the effect of vibrato on IOP/SPL, (4) the utilization of the vocal tract during execution of dynamic changes and vibrato, and (5) the impact of player experience on control of physical variables.","abstract_html":"Measurements of intraoral pressure (IOP) and sound pressure level (SPL) were taken of four oboists as they performed two sets of musical exercises: (1) crescendo-decrescendo from pp to ff and back to pp on the pitches D4, G4, C5 and A5, and (2) straight and vibrato performances of the same four pitches at mf. Video images of the vocal tract were also made using flexible fiberoptic nasoendoscopy (FFN). IOP and SPL data were captured in real time by the WinDaq®/Lite software package, with the dB meter located 8-9 inches in directly front of the oboe bell. The study yielded minimum and maximum values from 21.04 to 57.81 mm Hg and from 65.53 to 100.89 dB across all pitches examined. Discussion is included for the following topics: (1) the oboe’s sound envelope, or functional range of IOP and SPL values at different pitch levels, including the nonlinearity in the relationship between IOP and SPL on the oboe, (2) the static activation and kinetic maintenance thresholds for reed vibration, (3) the effect of vibrato on IOP/SPL, (4) the utilization of the vocal tract during execution of dynamic changes and vibrato, and (5) the impact of player experience on control of physical variables.","abstract_has_math":false,"creators":["Adduci, Michael Douglas"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Chesky, Kris S.","Veazey, Charles O.","Scott, John C. (John Charles), 1947-"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-12","date_published":"2011-12","updated_at":"2026-11-19T08:48:41Z","subjects":["vocal tract","intraoral pressure","laryngoscopy","FFN","vibrato","dynamics"],"languages":["English"],"rights":["Public","Adduci, Michael Douglas","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["oclc: 847197926","https://digital.library.unt.edu/ark:/67531/metadc103281/","ark: ark:/67531/metadc103281"],"render_values":[{"text":"oclc: 847197926","href":null,"code":true},{"text":"https://digital.library.unt.edu/ark:/67531/metadc103281/","href":"https://digital.library.unt.edu/ark:/67531/metadc103281/","code":true},{"text":"ark: ark:/67531/metadc103281","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.12794/metadc103281","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.12794/metadc103281","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc103281","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Chesky, Kris S.","Veazey, Charles O.","Scott, John C. (John Charles), 1947-"]},{"key":"dc:creator","label":"Author","values":["Adduci, Michael Douglas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-12"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:relation","label":"Dc Relation","values":["Lecture: July 14, 2011, ark:/67531/metadc171573"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["vocal tract","intraoral pressure","laryngoscopy","FFN","vibrato","dynamics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Adduci, Michael Douglas","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["oclc: 847197926","doi: 10.12794/metadc103281","https://digital.library.unt.edu/ark:/67531/metadc103281/","ark: ark:/67531/metadc103281"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Measurements of intraoral pressure (IOP) and sound pressure level (SPL) were taken of four oboists as they performed two sets of musical exercises: (1) crescendo-decrescendo from pp to ff and back to pp on the pitches D4, G4, C5 and A5, and (2) straight and vibrato performances of the same four pitches at mf. Video images of the vocal tract were also made using flexible fiberoptic nasoendoscopy (FFN). IOP and SPL data were captured in real time by the WinDaq®/Lite software package, with the dB meter located 8-9 inches in directly front of the oboe bell. The study yielded minimum and maximum values from 21.04 to 57.81 mm Hg and from 65.53 to 100.89 dB across all pitches examined. Discussion is included for the following topics: (1) the oboe’s sound envelope, or functional range of IOP and SPL values at different pitch levels, including the nonlinearity in the relationship between IOP and SPL on the oboe, (2) the static activation and kinetic maintenance thresholds for reed vibration, (3) the effect of vibrato on IOP/SPL, (4) the utilization of the vocal tract during execution of dynamic changes and vibrato, and (5) the impact of player experience on control of physical variables."]},{"key":"dc:format","label":"Dc Format","values":["Text"]},{"key":"dc:title","label":"Title","values":["Dynamic Measurement of Intraoral Pressure and Sound Pressure With Laryngoscopic Characterization During Oboe Performance"]}]}],"canonical_facts":{"dc:contributor":["Chesky, Kris S.","Veazey, Charles O.","Scott, John C. (John Charles), 1947-"],"dc:creator":["Adduci, Michael Douglas"],"dc:date":["2011-12"],"dc:description":["Measurements of intraoral pressure (IOP) and sound pressure level (SPL) were taken of four oboists as they performed two sets of musical exercises: (1) crescendo-decrescendo from pp to ff and back to pp on the pitches D4, G4, C5 and A5, and (2) straight and vibrato performances of the same four pitches at mf. Video images of the vocal tract were also made using flexible fiberoptic nasoendoscopy (FFN). IOP and SPL data were captured in real time by the WinDaq®/Lite software package, with the dB meter located 8-9 inches in directly front of the oboe bell. The study yielded minimum and maximum values from 21.04 to 57.81 mm Hg and from 65.53 to 100.89 dB across all pitches examined. Discussion is included for the following topics: (1) the oboe’s sound envelope, or functional range of IOP and SPL values at different pitch levels, including the nonlinearity in the relationship between IOP and SPL on the oboe, (2) the static activation and kinetic maintenance thresholds for reed vibration, (3) the effect of vibrato on IOP/SPL, (4) the utilization of the vocal tract during execution of dynamic changes and vibrato, and (5) the impact of player experience on control of physical variables."],"dc:format":["Text"],"dc:identifier":["oclc: 847197926","doi: 10.12794/metadc103281","https://digital.library.unt.edu/ark:/67531/metadc103281/","ark: ark:/67531/metadc103281"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:relation":["Lecture: July 14, 2011, ark:/67531/metadc171573"],"dc:rights":["Public","Adduci, Michael Douglas","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"dc:subject":["vocal tract","intraoral pressure","laryngoscopy","FFN","vibrato","dynamics"],"dc:title":["Dynamic Measurement of Intraoral Pressure and Sound Pressure With Laryngoscopic Characterization During Oboe Performance"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:48:41Z"}