{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc103393"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc103393","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"High-Precision Micropipette Thermal Sensor for Measurement of Thermal Conductivity of Carbon Nanotubes Thin Film","abstract":"The thesis describes novel glass micropipette thermal sensor fabricated in cost-effective manner and thermal conductivity measurement of carbon nanotubes (CNT) thin film using the developed sensor. Various micrometer-sized sensors, which range from 2 µm to 30 µm, were produced and tested. The capability of the sensor in measuring thermal fluctuation at micro level with an estimated resolution of ±0.002oC is demonstrated. The sensitivity of sensors was recorded from 3.34 to 8.86 µV/oC, which is independent of tip size and dependent on the coating of Nickel. The detailed experimental setup for thermal conductivity measurement of CNT film is discussed and 73.418 W/moC was determined as the thermal conductivity of the CNT film at room temperature.","abstract_html":"The thesis describes novel glass micropipette thermal sensor fabricated in cost-effective manner and thermal conductivity measurement of carbon nanotubes (CNT) thin film using the developed sensor. Various micrometer-sized sensors, which range from 2 µm to 30 µm, were produced and tested. The capability of the sensor in measuring thermal fluctuation at micro level with an estimated resolution of ±0.002oC is demonstrated. The sensitivity of sensors was recorded from 3.34 to 8.86 µV/oC, which is independent of tip size and dependent on the coating of Nickel. The detailed experimental setup for thermal conductivity measurement of CNT film is discussed and 73.418 W/moC was determined as the thermal conductivity of the CNT film at room temperature.","abstract_has_math":false,"creators":["Shrestha, Ramesh"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Choi, Tae-Youl","Boetcher, Sandra","Tao, Yong X."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-08","date_published":"2011-08","updated_at":"2026-11-19T08:48:41Z","subjects":["micropipette","thin film","Nickel coating","carbon nanotubes","thermal conductivity"],"languages":["English"],"rights":["Public","Shrestha, Ramesh","Copyright","Copyright is held by the author, unless otherwise noted. All rights"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digital.library.unt.edu/ark:/67531/metadc103393/","ark: ark:/67531/metadc103393"],"render_values":[{"text":"https://digital.library.unt.edu/ark:/67531/metadc103393/","href":"https://digital.library.unt.edu/ark:/67531/metadc103393/","code":true},{"text":"ark: ark:/67531/metadc103393","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.12794/metadc103393","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.12794/metadc103393","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc103393","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Choi, Tae-Youl","Boetcher, Sandra","Tao, Yong X."]},{"key":"dc:creator","label":"Author","values":["Shrestha, Ramesh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-08"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["micropipette","thin film","Nickel coating","carbon nanotubes","thermal conductivity"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Shrestha, Ramesh","Copyright","Copyright is held by the author, unless otherwise noted. All rights"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["doi: 10.12794/metadc103393","https://digital.library.unt.edu/ark:/67531/metadc103393/","ark: ark:/67531/metadc103393"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The thesis describes novel glass micropipette thermal sensor fabricated in cost-effective manner and thermal conductivity measurement of carbon nanotubes (CNT) thin film using the developed sensor. Various micrometer-sized sensors, which range from 2 µm to 30 µm, were produced and tested. The capability of the sensor in measuring thermal fluctuation at micro level with an estimated resolution of ±0.002oC is demonstrated. The sensitivity of sensors was recorded from 3.34 to 8.86 µV/oC, which is independent of tip size and dependent on the coating of Nickel. The detailed experimental setup for thermal conductivity measurement of CNT film is discussed and 73.418 W/moC was determined as the thermal conductivity of the CNT film at room temperature."]},{"key":"dc:format","label":"Dc Format","values":["Text"]},{"key":"dc:title","label":"Title","values":["High-Precision Micropipette Thermal Sensor for Measurement of Thermal Conductivity of Carbon Nanotubes Thin Film"]}]}],"canonical_facts":{"dc:contributor":["Choi, Tae-Youl","Boetcher, Sandra","Tao, Yong X."],"dc:creator":["Shrestha, Ramesh"],"dc:date":["2011-08"],"dc:description":["The thesis describes novel glass micropipette thermal sensor fabricated in cost-effective manner and thermal conductivity measurement of carbon nanotubes (CNT) thin film using the developed sensor. Various micrometer-sized sensors, which range from 2 µm to 30 µm, were produced and tested. The capability of the sensor in measuring thermal fluctuation at micro level with an estimated resolution of ±0.002oC is demonstrated. The sensitivity of sensors was recorded from 3.34 to 8.86 µV/oC, which is independent of tip size and dependent on the coating of Nickel. The detailed experimental setup for thermal conductivity measurement of CNT film is discussed and 73.418 W/moC was determined as the thermal conductivity of the CNT film at room temperature."],"dc:format":["Text"],"dc:identifier":["doi: 10.12794/metadc103393","https://digital.library.unt.edu/ark:/67531/metadc103393/","ark: ark:/67531/metadc103393"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Shrestha, Ramesh","Copyright","Copyright is held by the author, unless otherwise noted. All rights"],"dc:subject":["micropipette","thin film","Nickel coating","carbon nanotubes","thermal conductivity"],"dc:title":["High-Precision Micropipette Thermal Sensor for Measurement of Thermal Conductivity of Carbon Nanotubes Thin Film"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:48:41Z"}