{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc1062814"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc1062814","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Shear and Bending Strength of Cold-Formed Steel Solid Wall Panels Using Corrugated Steel Sheets for Mobile Shelters","abstract":"The objective of this thesis is to determine if the single sided resistance spot weld (RSW) can be used as a feasible connection method for cold formed steel (CFS) shear walls subject to lateral force of either seismic or wind loads on mobile shelters. The research consisted of three phases which include: a design as a 3D BIM model, connection tests of the resistance spot weld, and full-scale testing of the designed solid wall panels. The shear wall testing was conducted on specimens with both resistance spot weld and self-drilling screws and the results from tests gave a direct comparison of these connections when the solid wall panel was subjected to in-plane shear forces. The full-scale tests also included 4-point bending tests which was designed to investigate the wall panel's resistance to the lateral loads applied perpendicularly to the surface. The research discovered that the singled sided resistance spot weld achieved similar performance as the self-drilling screws in the applications of CFS wall panels for mobile shelters. The proposed single sided resistance spot weld has advantages of low cost, no added weight, fast fabrication, and it is a feasible connection method for CFS wall panels.","abstract_html":"The objective of this thesis is to determine if the single sided resistance spot weld (RSW) can be used as a feasible connection method for cold formed steel (CFS) shear walls subject to lateral force of either seismic or wind loads on mobile shelters. The research consisted of three phases which include: a design as a 3D BIM model, connection tests of the resistance spot weld, and full-scale testing of the designed solid wall panels. The shear wall testing was conducted on specimens with both resistance spot weld and self-drilling screws and the results from tests gave a direct comparison of these connections when the solid wall panel was subjected to in-plane shear forces. The full-scale tests also included 4-point bending tests which was designed to investigate the wall panel&#x27;s resistance to the lateral loads applied perpendicularly to the surface. The research discovered that the singled sided resistance spot weld achieved similar performance as the self-drilling screws in the applications of CFS wall panels for mobile shelters. The proposed single sided resistance spot weld has advantages of low cost, no added weight, fast fabrication, and it is a feasible connection method for CFS wall panels.","abstract_has_math":false,"creators":["Derrick, Nathan"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Yu, Cheng, 1974-","Nasrazadani, Seifollah, 1956-","Zhang, Haifeng, 1974-"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-12","date_published":"2017-12","updated_at":"2026-11-19T08:54:38Z","subjects":["Cold-Formed Steel Shear Wall","Spot Weld Connection","Engineering, General","Engineering, Materials Science","Steel -- Cold working.","Shear walls.","Welded joints.","Steel, Structural -- Testing."],"languages":["English"],"rights":["Public","Derrick, Nathan","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_977","https://digital.library.unt.edu/ark:/67531/metadc1062814/","ark: ark:/67531/metadc1062814"],"render_values":[{"text":"local-cont-no: submission_977","href":null,"code":true},{"text":"https://digital.library.unt.edu/ark:/67531/metadc1062814/","href":"https://digital.library.unt.edu/ark:/67531/metadc1062814/","code":true},{"text":"ark: ark:/67531/metadc1062814","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.12794/metadc1062814","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.12794/metadc1062814","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aunt%3Ainfo%3Aark%2F67531%2Fmetadc1062814","prefix":"oai_dc"},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc1062814","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Yu, Cheng, 1974-","Nasrazadani, Seifollah, 1956-","Zhang, Haifeng, 1974-"]},{"key":"dc:creator","label":"Author","values":["Derrick, Nathan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-12"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Cold-Formed Steel Shear Wall","Spot Weld Connection","Engineering, General","Engineering, Materials Science","Steel -- Cold working.","Shear walls.","Welded joints.","Steel, Structural -- Testing."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Derrick, Nathan","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_977","doi: 10.12794/metadc1062814","https://digital.library.unt.edu/ark:/67531/metadc1062814/","ark: ark:/67531/metadc1062814"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The objective of this thesis is to determine if the single sided resistance spot weld (RSW) can be used as a feasible connection method for cold formed steel (CFS) shear walls subject to lateral force of either seismic or wind loads on mobile shelters. The research consisted of three phases which include: a design as a 3D BIM model, connection tests of the resistance spot weld, and full-scale testing of the designed solid wall panels. The shear wall testing was conducted on specimens with both resistance spot weld and self-drilling screws and the results from tests gave a direct comparison of these connections when the solid wall panel was subjected to in-plane shear forces. The full-scale tests also included 4-point bending tests which was designed to investigate the wall panel's resistance to the lateral loads applied perpendicularly to the surface. The research discovered that the singled sided resistance spot weld achieved similar performance as the self-drilling screws in the applications of CFS wall panels for mobile shelters. The proposed single sided resistance spot weld has advantages of low cost, no added weight, fast fabrication, and it is a feasible connection method for CFS wall panels."]},{"key":"dc:format","label":"Dc Format","values":["viii, 47 pages","Text"]},{"key":"dc:title","label":"Title","values":["Shear and Bending Strength of Cold-Formed Steel Solid Wall Panels Using Corrugated Steel Sheets for Mobile Shelters"]}]}],"canonical_facts":{"dc:contributor":["Yu, Cheng, 1974-","Nasrazadani, Seifollah, 1956-","Zhang, Haifeng, 1974-"],"dc:creator":["Derrick, Nathan"],"dc:date":["2017-12"],"dc:description":["The objective of this thesis is to determine if the single sided resistance spot weld (RSW) can be used as a feasible connection method for cold formed steel (CFS) shear walls subject to lateral force of either seismic or wind loads on mobile shelters. The research consisted of three phases which include: a design as a 3D BIM model, connection tests of the resistance spot weld, and full-scale testing of the designed solid wall panels. The shear wall testing was conducted on specimens with both resistance spot weld and self-drilling screws and the results from tests gave a direct comparison of these connections when the solid wall panel was subjected to in-plane shear forces. The full-scale tests also included 4-point bending tests which was designed to investigate the wall panel's resistance to the lateral loads applied perpendicularly to the surface. The research discovered that the singled sided resistance spot weld achieved similar performance as the self-drilling screws in the applications of CFS wall panels for mobile shelters. The proposed single sided resistance spot weld has advantages of low cost, no added weight, fast fabrication, and it is a feasible connection method for CFS wall panels."],"dc:format":["viii, 47 pages","Text"],"dc:identifier":["local-cont-no: submission_977","doi: 10.12794/metadc1062814","https://digital.library.unt.edu/ark:/67531/metadc1062814/","ark: ark:/67531/metadc1062814"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Derrick, Nathan","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"dc:subject":["Cold-Formed Steel Shear Wall","Spot Weld Connection","Engineering, General","Engineering, Materials Science","Steel -- Cold working.","Shear walls.","Welded joints.","Steel, Structural -- Testing."],"dc:title":["Shear and Bending Strength of Cold-Formed Steel Solid Wall Panels Using Corrugated Steel Sheets for Mobile Shelters"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:54:38Z"}