{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc1538705"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc1538705","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Modeling and Design of Antennas for Loosely Coupled Links in Wireless Power Transfer Applications","abstract":"Wireless power transfer (WPT) systems are important in many areas, such as medical, communication, transportation, and consumer electronics. The underlying WPT system is comprised of a transmitter (TX) and receiver (RX). For biomedical applications, such systems can be implemented on rigid or flexible substrates and can be implanted or wearable. The efficiency of a WPT system is based on power transfer efficiency (PTE). Many WPT system optimization techniques have been explored to achieve the highest PTE possible. These are based on either a figure-of-merit (FOM) approach, quality factor (Q-factor) maximization, or by sweeping values for coil geometries. Four WPT systems for biomedical applications are implemented with inductive coupling. The thesis later presents an optimization technique for finding the maximum PTE of a range of frequencies and coil shapes through frequency, geometry and shape sweeping. Five optimized TX coil designs for different operating frequencies are fabricated for three shapes: square, hexagonal, and octagonal planar-spirals. The corresponding RX is implemented on polyimide tape with ink-jet-print (IJP) silver. At 80 MHz, the maximum measured PTE achieved is 2.781% at a 10 mm distance in the air for square planar-spiral coils.","abstract_html":"Wireless power transfer (WPT) systems are important in many areas, such as medical, communication, transportation, and consumer electronics. The underlying WPT system is comprised of a transmitter (TX) and receiver (RX). For biomedical applications, such systems can be implemented on rigid or flexible substrates and can be implanted or wearable. The efficiency of a WPT system is based on power transfer efficiency (PTE). Many WPT system optimization techniques have been explored to achieve the highest PTE possible. These are based on either a figure-of-merit (FOM) approach, quality factor (Q-factor) maximization, or by sweeping values for coil geometries. Four WPT systems for biomedical applications are implemented with inductive coupling. The thesis later presents an optimization technique for finding the maximum PTE of a range of frequencies and coil shapes through frequency, geometry and shape sweeping. Five optimized TX coil designs for different operating frequencies are fabricated for three shapes: square, hexagonal, and octagonal planar-spirals. The corresponding RX is implemented on polyimide tape with ink-jet-print (IJP) silver. At 80 MHz, the maximum measured PTE achieved is 2.781% at a 10 mm distance in the air for square planar-spiral coils.","abstract_has_math":false,"creators":["Sinclair, Melissa Ann"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Mahbub, Ifana","Li, Xinrong","Namuduri, Kamesh"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-08","date_published":"2019-08","updated_at":"2026-11-19T08:54:49Z","subjects":["Wireless Power Transfer","Inductive Coupling","Inductive Power Transfer","Optimization","Ink-Jet-Printing","Flexible Substrate","Mutual Coupling","Electromagnetic Modeling","Implants","Wearable Sensors","Engineering, Electronics and Electrical","Engineering, Biomedical"],"languages":["English"],"rights":["Public","Sinclair, Melissa Ann","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_1689","https://digital.library.unt.edu/ark:/67531/metadc1538705/","ark: ark:/67531/metadc1538705"],"render_values":[{"text":"local-cont-no: submission_1689","href":null,"code":true},{"text":"https://digital.library.unt.edu/ark:/67531/metadc1538705/","href":"https://digital.library.unt.edu/ark:/67531/metadc1538705/","code":true},{"text":"ark: ark:/67531/metadc1538705","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.12794/metadc1538705","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.12794/metadc1538705","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc1538705","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Mahbub, Ifana","Li, Xinrong","Namuduri, Kamesh"]},{"key":"dc:creator","label":"Author","values":["Sinclair, Melissa Ann"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019-08"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Wireless Power Transfer","Inductive Coupling","Inductive Power Transfer","Optimization","Ink-Jet-Printing","Flexible Substrate","Mutual Coupling","Electromagnetic Modeling","Implants","Wearable Sensors","Engineering, Electronics and Electrical","Engineering, Biomedical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Sinclair, Melissa Ann","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_1689","doi: 10.12794/metadc1538705","https://digital.library.unt.edu/ark:/67531/metadc1538705/","ark: ark:/67531/metadc1538705"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Wireless power transfer (WPT) systems are important in many areas, such as medical, communication, transportation, and consumer electronics. The underlying WPT system is comprised of a transmitter (TX) and receiver (RX). For biomedical applications, such systems can be implemented on rigid or flexible substrates and can be implanted or wearable. The efficiency of a WPT system is based on power transfer efficiency (PTE). Many WPT system optimization techniques have been explored to achieve the highest PTE possible. These are based on either a figure-of-merit (FOM) approach, quality factor (Q-factor) maximization, or by sweeping values for coil geometries. Four WPT systems for biomedical applications are implemented with inductive coupling. The thesis later presents an optimization technique for finding the maximum PTE of a range of frequencies and coil shapes through frequency, geometry and shape sweeping. Five optimized TX coil designs for different operating frequencies are fabricated for three shapes: square, hexagonal, and octagonal planar-spirals. The corresponding RX is implemented on polyimide tape with ink-jet-print (IJP) silver. At 80 MHz, the maximum measured PTE achieved is 2.781% at a 10 mm distance in the air for square planar-spiral coils."]},{"key":"dc:format","label":"Dc Format","values":["x, 71 pages","Text"]},{"key":"dc:title","label":"Title","values":["Modeling and Design of Antennas for Loosely Coupled Links in Wireless Power Transfer Applications"]}]}],"canonical_facts":{"dc:contributor":["Mahbub, Ifana","Li, Xinrong","Namuduri, Kamesh"],"dc:creator":["Sinclair, Melissa Ann"],"dc:date":["2019-08"],"dc:description":["Wireless power transfer (WPT) systems are important in many areas, such as medical, communication, transportation, and consumer electronics. The underlying WPT system is comprised of a transmitter (TX) and receiver (RX). For biomedical applications, such systems can be implemented on rigid or flexible substrates and can be implanted or wearable. The efficiency of a WPT system is based on power transfer efficiency (PTE). Many WPT system optimization techniques have been explored to achieve the highest PTE possible. These are based on either a figure-of-merit (FOM) approach, quality factor (Q-factor) maximization, or by sweeping values for coil geometries. Four WPT systems for biomedical applications are implemented with inductive coupling. The thesis later presents an optimization technique for finding the maximum PTE of a range of frequencies and coil shapes through frequency, geometry and shape sweeping. Five optimized TX coil designs for different operating frequencies are fabricated for three shapes: square, hexagonal, and octagonal planar-spirals. The corresponding RX is implemented on polyimide tape with ink-jet-print (IJP) silver. At 80 MHz, the maximum measured PTE achieved is 2.781% at a 10 mm distance in the air for square planar-spiral coils."],"dc:format":["x, 71 pages","Text"],"dc:identifier":["local-cont-no: submission_1689","doi: 10.12794/metadc1538705","https://digital.library.unt.edu/ark:/67531/metadc1538705/","ark: ark:/67531/metadc1538705"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Sinclair, Melissa Ann","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"dc:subject":["Wireless Power Transfer","Inductive Coupling","Inductive Power Transfer","Optimization","Ink-Jet-Printing","Flexible Substrate","Mutual Coupling","Electromagnetic Modeling","Implants","Wearable Sensors","Engineering, Electronics and Electrical","Engineering, Biomedical"],"dc:title":["Modeling and Design of Antennas for Loosely Coupled Links in Wireless Power Transfer Applications"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:54:49Z"}