{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc1703340"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc1703340","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Design of a Wearable Flexible Resonant Body Temperature Sensor with Inkjet-Printing","abstract":"A wearable body temperature sensor would allow for early detection of fever or infection, as well as frequent and accurate hassle-free recording. This thesis explores the design of a body-temperature-sensing device inkjet-printed on a flexible substrate. All structures were first modeled by first-principles, theoretical calculations, and then simulated in HFSS. A variety of planar square inductor geometries were studied before selecting an optimal design. The designs were fabricated using multiple techniques and compared to the simulation results. It was determined that inductance must be carefully measured and documented to ensure good functionality. The same is true for parallel-plate and interdigitated capacitors. While inductance remains relatively constant with temperature, the capacitance of the device with a temperature-sensitive dielectric layer will result in a shift in the resonant frequency as environmental or ambient temperature changes. This resonant frequency can be wirelessly detected, with no battery required for the sensing device, from which the temperature can be deduced. From this work, the optimized version of the design comprises of conductive silver in with a temperature-sensitive graphene oxide layer, intended for inkjet-printing on flexible polyimide substrates. Graphene oxide demonstrates a high dielectric permittivity with good sensing capabilities and high accuracy. This work pushes the state-of-the-art in applying these novel materials and techniques to enable flexible body temperature sensors for future biomedical applications.","abstract_html":"A wearable body temperature sensor would allow for early detection of fever or infection, as well as frequent and accurate hassle-free recording. This thesis explores the design of a body-temperature-sensing device inkjet-printed on a flexible substrate. All structures were first modeled by first-principles, theoretical calculations, and then simulated in HFSS. A variety of planar square inductor geometries were studied before selecting an optimal design. The designs were fabricated using multiple techniques and compared to the simulation results. It was determined that inductance must be carefully measured and documented to ensure good functionality. The same is true for parallel-plate and interdigitated capacitors. While inductance remains relatively constant with temperature, the capacitance of the device with a temperature-sensitive dielectric layer will result in a shift in the resonant frequency as environmental or ambient temperature changes. This resonant frequency can be wirelessly detected, with no battery required for the sensing device, from which the temperature can be deduced. From this work, the optimized version of the design comprises of conductive silver in with a temperature-sensitive graphene oxide layer, intended for inkjet-printing on flexible polyimide substrates. Graphene oxide demonstrates a high dielectric permittivity with good sensing capabilities and high accuracy. This work pushes the state-of-the-art in applying these novel materials and techniques to enable flexible body temperature sensors for future biomedical applications.","abstract_has_math":false,"creators":["Horn, Jacqueline Marie"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Kaul, Anupama B.","Mahbub, Ifana","Mehta, Gayatri","Li, Xinrong"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-05","date_published":"2020-05","updated_at":"2026-11-19T08:54:49Z","subjects":["resonance; RF; frequency spectrum;","temperature sensor; inkjet-printing; dielectric materials;","parallel-plate; capacitor; interdigital capacitor; HFSS; inductor; spiral inductor; temperature; body temperature; wearable electronics; flexible electronics; healthcare monitoring; hexagonal boron nitride; graphene oxide; conductive silver ink;"],"languages":["English"],"rights":["Public","Horn, Jacqueline Marie","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_2022","https://digital.library.unt.edu/ark:/67531/metadc1703340/","ark: ark:/67531/metadc1703340"],"render_values":[{"text":"local-cont-no: submission_2022","href":null,"code":true},{"text":"https://digital.library.unt.edu/ark:/67531/metadc1703340/","href":"https://digital.library.unt.edu/ark:/67531/metadc1703340/","code":true},{"text":"ark: ark:/67531/metadc1703340","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.12794/metadc1703340","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.12794/metadc1703340","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc1703340","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kaul, Anupama B.","Mahbub, Ifana","Mehta, Gayatri","Li, Xinrong"]},{"key":"dc:creator","label":"Author","values":["Horn, Jacqueline Marie"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-05"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["resonance; RF; frequency spectrum;","temperature sensor; inkjet-printing; dielectric materials;","parallel-plate; capacitor; interdigital capacitor; HFSS; inductor; spiral inductor; temperature; body temperature; wearable electronics; flexible electronics; healthcare monitoring; hexagonal boron nitride; graphene oxide; conductive silver ink;"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Horn, Jacqueline Marie","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_2022","doi: 10.12794/metadc1703340","https://digital.library.unt.edu/ark:/67531/metadc1703340/","ark: ark:/67531/metadc1703340"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A wearable body temperature sensor would allow for early detection of fever or infection, as well as frequent and accurate hassle-free recording. This thesis explores the design of a body-temperature-sensing device inkjet-printed on a flexible substrate. All structures were first modeled by first-principles, theoretical calculations, and then simulated in HFSS. A variety of planar square inductor geometries were studied before selecting an optimal design. The designs were fabricated using multiple techniques and compared to the simulation results. It was determined that inductance must be carefully measured and documented to ensure good functionality. The same is true for parallel-plate and interdigitated capacitors. While inductance remains relatively constant with temperature, the capacitance of the device with a temperature-sensitive dielectric layer will result in a shift in the resonant frequency as environmental or ambient temperature changes. This resonant frequency can be wirelessly detected, with no battery required for the sensing device, from which the temperature can be deduced. From this work, the optimized version of the design comprises of conductive silver in with a temperature-sensitive graphene oxide layer, intended for inkjet-printing on flexible polyimide substrates. Graphene oxide demonstrates a high dielectric permittivity with good sensing capabilities and high accuracy. This work pushes the state-of-the-art in applying these novel materials and techniques to enable flexible body temperature sensors for future biomedical applications."]},{"key":"dc:format","label":"Dc Format","values":["ix, 76 pages","Text"]},{"key":"dc:title","label":"Title","values":["Design of a Wearable Flexible Resonant Body Temperature Sensor with Inkjet-Printing"]}]}],"canonical_facts":{"dc:contributor":["Kaul, Anupama B.","Mahbub, Ifana","Mehta, Gayatri","Li, Xinrong"],"dc:creator":["Horn, Jacqueline Marie"],"dc:date":["2020-05"],"dc:description":["A wearable body temperature sensor would allow for early detection of fever or infection, as well as frequent and accurate hassle-free recording. This thesis explores the design of a body-temperature-sensing device inkjet-printed on a flexible substrate. All structures were first modeled by first-principles, theoretical calculations, and then simulated in HFSS. A variety of planar square inductor geometries were studied before selecting an optimal design. The designs were fabricated using multiple techniques and compared to the simulation results. It was determined that inductance must be carefully measured and documented to ensure good functionality. The same is true for parallel-plate and interdigitated capacitors. While inductance remains relatively constant with temperature, the capacitance of the device with a temperature-sensitive dielectric layer will result in a shift in the resonant frequency as environmental or ambient temperature changes. This resonant frequency can be wirelessly detected, with no battery required for the sensing device, from which the temperature can be deduced. From this work, the optimized version of the design comprises of conductive silver in with a temperature-sensitive graphene oxide layer, intended for inkjet-printing on flexible polyimide substrates. Graphene oxide demonstrates a high dielectric permittivity with good sensing capabilities and high accuracy. This work pushes the state-of-the-art in applying these novel materials and techniques to enable flexible body temperature sensors for future biomedical applications."],"dc:format":["ix, 76 pages","Text"],"dc:identifier":["local-cont-no: submission_2022","doi: 10.12794/metadc1703340","https://digital.library.unt.edu/ark:/67531/metadc1703340/","ark: ark:/67531/metadc1703340"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Horn, Jacqueline Marie","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"dc:subject":["resonance; RF; frequency spectrum;","temperature sensor; inkjet-printing; dielectric materials;","parallel-plate; capacitor; interdigital capacitor; HFSS; inductor; spiral inductor; temperature; body temperature; wearable electronics; flexible electronics; healthcare monitoring; hexagonal boron nitride; graphene oxide; conductive silver ink;"],"dc:title":["Design of a Wearable Flexible Resonant Body Temperature Sensor with Inkjet-Printing"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:54:49Z"}