{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc1752325"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc1752325","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Application of Novel Microporous Polyolefin Silica-Based Substrate in Paper Spray Mass Spectrometry (PS-MS)","abstract":"This study addressed five key applications of paper spray mass spectrometry (PS-MS): (i) comparative analysis of the microporous substrate with the cellulose-based substrate in drug detection; (ii) detection of more than 190 fentanyl analogs with their fragmentation pattern can be implemented in the future reference for quicker, accurate and sensitive determination; (iii) exploring sweat in a fingerprint to be considered an alternate method to recognize non-invasive markers of metabolites, lipids, narcotics, and explosive residues that can be used in forensic testing applications; (iv) extending and improving better, cost-effective and quick real-time monitoring of the diseased stage using biofluid samples to obtain vastly different lipid information in viral infection such as COVID-19; and (v) mass spectral detection in chemical warfare agent (CWA) stimulant gas exposure with microporous structure absorbency capabilities in air quality monitoring. This novel synthetic material is known as Teslin® (PPG Industries), consisting of a microporous polyolefin single-layered silica matrix, can be used for precise, sensitive, selective, and rapid sample analysis with PS-MS. The Teslin® substrate provided longer activation time for samples and an active signal with a higher concentration of ion formation and mobility compared to cellulose-based papers. Direct analysis of multiple samples showed that, besides being more sensitive to the study and highly efficient with less sample size and spray solvent needed, Teslin® had less interaction with paper source molecules. For less than 60 seconds of processing time, PS-MS can be used as a rapid detection tool, with limited sample preparation requiring less than one microgram of the sample. Overall, the data in this analysis indicate the capacity of the PS-MS as an alternative approach for direct chemical analysis in many applications. Specifically, the waterproof and microporosity characteristics of Teslin® have proven its usefulness in detecting a variety of chemical components in liquid, solid, and gaseous phases without requiring any chemical treatment or substrate alteration.","abstract_html":"This study addressed five key applications of paper spray mass spectrometry (PS-MS): (i) comparative analysis of the microporous substrate with the cellulose-based substrate in drug detection; (ii) detection of more than 190 fentanyl analogs with their fragmentation pattern can be implemented in the future reference for quicker, accurate and sensitive determination; (iii) exploring sweat in a fingerprint to be considered an alternate method to recognize non-invasive markers of metabolites, lipids, narcotics, and explosive residues that can be used in forensic testing applications; (iv) extending and improving better, cost-effective and quick real-time monitoring of the diseased stage using biofluid samples to obtain vastly different lipid information in viral infection such as COVID-19; and (v) mass spectral detection in chemical warfare agent (CWA) stimulant gas exposure with microporous structure absorbency capabilities in air quality monitoring. This novel synthetic material is known as Teslin® (PPG Industries), consisting of a microporous polyolefin single-layered silica matrix, can be used for precise, sensitive, selective, and rapid sample analysis with PS-MS. The Teslin® substrate provided longer activation time for samples and an active signal with a higher concentration of ion formation and mobility compared to cellulose-based papers. Direct analysis of multiple samples showed that, besides being more sensitive to the study and highly efficient with less sample size and spray solvent needed, Teslin® had less interaction with paper source molecules. For less than 60 seconds of processing time, PS-MS can be used as a rapid detection tool, with limited sample preparation requiring less than one microgram of the sample. Overall, the data in this analysis indicate the capacity of the PS-MS as an alternative approach for direct chemical analysis in many applications. Specifically, the waterproof and microporosity characteristics of Teslin® have proven its usefulness in detecting a variety of chemical components in liquid, solid, and gaseous phases without requiring any chemical treatment or substrate alteration.","abstract_has_math":false,"creators":["Weligamage De Silva, Imesha"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Verbeck, Guido F.","Golden, Teresa D.","Cisneros, Andrés","Jagadeeswaran, Pudur"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-12","date_published":"2020-12","updated_at":"2026-11-19T08:55:03Z","subjects":["paper spray mass spectrometry (PS-MS)","microporous polyolefin single-layered silica matrix","fingerprints","metabolites","lipids","drugs","explosives","chemical warfare agent (CWA) stimulant","gas exposure","Chemistry, Analytical","Chemistry, Biochemistry","Anthropology, Medical and Forensic"],"languages":["English"],"rights":["Public","Weligamage De Silva, Imesha","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_2248","https://digital.library.unt.edu/ark:/67531/metadc1752325/","ark: ark:/67531/metadc1752325"],"render_values":[{"text":"local-cont-no: submission_2248","href":null,"code":true},{"text":"https://digital.library.unt.edu/ark:/67531/metadc1752325/","href":"https://digital.library.unt.edu/ark:/67531/metadc1752325/","code":true},{"text":"ark: ark:/67531/metadc1752325","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.12794/metadc1752325","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.12794/metadc1752325","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc1752325","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Verbeck, Guido F.","Golden, Teresa D.","Cisneros, Andrés","Jagadeeswaran, Pudur"]},{"key":"dc:creator","label":"Author","values":["Weligamage De Silva, Imesha"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-12"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["paper spray mass spectrometry (PS-MS)","microporous polyolefin single-layered silica matrix","fingerprints","metabolites","lipids","drugs","explosives","chemical warfare agent (CWA) stimulant","gas exposure","Chemistry, Analytical","Chemistry, Biochemistry","Anthropology, Medical and Forensic"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Weligamage De Silva, Imesha","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_2248","doi: 10.12794/metadc1752325","https://digital.library.unt.edu/ark:/67531/metadc1752325/","ark: ark:/67531/metadc1752325"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This study addressed five key applications of paper spray mass spectrometry (PS-MS): (i) comparative analysis of the microporous substrate with the cellulose-based substrate in drug detection; (ii) detection of more than 190 fentanyl analogs with their fragmentation pattern can be implemented in the future reference for quicker, accurate and sensitive determination; (iii) exploring sweat in a fingerprint to be considered an alternate method to recognize non-invasive markers of metabolites, lipids, narcotics, and explosive residues that can be used in forensic testing applications; (iv) extending and improving better, cost-effective and quick real-time monitoring of the diseased stage using biofluid samples to obtain vastly different lipid information in viral infection such as COVID-19; and (v) mass spectral detection in chemical warfare agent (CWA) stimulant gas exposure with microporous structure absorbency capabilities in air quality monitoring. This novel synthetic material is known as Teslin® (PPG Industries), consisting of a microporous polyolefin single-layered silica matrix, can be used for precise, sensitive, selective, and rapid sample analysis with PS-MS. The Teslin® substrate provided longer activation time for samples and an active signal with a higher concentration of ion formation and mobility compared to cellulose-based papers. Direct analysis of multiple samples showed that, besides being more sensitive to the study and highly efficient with less sample size and spray solvent needed, Teslin® had less interaction with paper source molecules. For less than 60 seconds of processing time, PS-MS can be used as a rapid detection tool, with limited sample preparation requiring less than one microgram of the sample. Overall, the data in this analysis indicate the capacity of the PS-MS as an alternative approach for direct chemical analysis in many applications. Specifically, the waterproof and microporosity characteristics of Teslin® have proven its usefulness in detecting a variety of chemical components in liquid, solid, and gaseous phases without requiring any chemical treatment or substrate alteration."]},{"key":"dc:format","label":"Dc Format","values":["xii, 143 pages","Text"]},{"key":"dc:title","label":"Title","values":["Application of Novel Microporous Polyolefin Silica-Based Substrate in Paper Spray Mass Spectrometry (PS-MS)"]}]}],"canonical_facts":{"dc:contributor":["Verbeck, Guido F.","Golden, Teresa D.","Cisneros, Andrés","Jagadeeswaran, Pudur"],"dc:creator":["Weligamage De Silva, Imesha"],"dc:date":["2020-12"],"dc:description":["This study addressed five key applications of paper spray mass spectrometry (PS-MS): (i) comparative analysis of the microporous substrate with the cellulose-based substrate in drug detection; (ii) detection of more than 190 fentanyl analogs with their fragmentation pattern can be implemented in the future reference for quicker, accurate and sensitive determination; (iii) exploring sweat in a fingerprint to be considered an alternate method to recognize non-invasive markers of metabolites, lipids, narcotics, and explosive residues that can be used in forensic testing applications; (iv) extending and improving better, cost-effective and quick real-time monitoring of the diseased stage using biofluid samples to obtain vastly different lipid information in viral infection such as COVID-19; and (v) mass spectral detection in chemical warfare agent (CWA) stimulant gas exposure with microporous structure absorbency capabilities in air quality monitoring. This novel synthetic material is known as Teslin® (PPG Industries), consisting of a microporous polyolefin single-layered silica matrix, can be used for precise, sensitive, selective, and rapid sample analysis with PS-MS. The Teslin® substrate provided longer activation time for samples and an active signal with a higher concentration of ion formation and mobility compared to cellulose-based papers. Direct analysis of multiple samples showed that, besides being more sensitive to the study and highly efficient with less sample size and spray solvent needed, Teslin® had less interaction with paper source molecules. For less than 60 seconds of processing time, PS-MS can be used as a rapid detection tool, with limited sample preparation requiring less than one microgram of the sample. Overall, the data in this analysis indicate the capacity of the PS-MS as an alternative approach for direct chemical analysis in many applications. Specifically, the waterproof and microporosity characteristics of Teslin® have proven its usefulness in detecting a variety of chemical components in liquid, solid, and gaseous phases without requiring any chemical treatment or substrate alteration."],"dc:format":["xii, 143 pages","Text"],"dc:identifier":["local-cont-no: submission_2248","doi: 10.12794/metadc1752325","https://digital.library.unt.edu/ark:/67531/metadc1752325/","ark: ark:/67531/metadc1752325"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Weligamage De Silva, Imesha","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"dc:subject":["paper spray mass spectrometry (PS-MS)","microporous polyolefin single-layered silica matrix","fingerprints","metabolites","lipids","drugs","explosives","chemical warfare agent (CWA) stimulant","gas exposure","Chemistry, Analytical","Chemistry, Biochemistry","Anthropology, Medical and Forensic"],"dc:title":["Application of Novel Microporous Polyolefin Silica-Based Substrate in Paper Spray Mass Spectrometry (PS-MS)"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:55:03Z"}