{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc1944251"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc1944251","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Wireless Power Transfer and Power Management Unit Integrated with Low-Power IR-UWB Transmitter for Neuromodulation and Self-Powered Sensor Applications","abstract":"This dissertation is particularly focused on a novel approach of a wirelessly powered neuromodulation system for chronic patients. The inductively coupled transmitter (TX) and receiver (RX) coils are designed through optimization to achieve maximum efficiency. A power management unit (PMU) consisting of a voltage rectifier, voltage regulator along with a stimulation circuitry is also designed to provide pulse stimulation to genetically modified neurons. For continuous health monitoring purposes, the response from the brain due to stimulation needs to be recorded and transmitted wirelessly outside the brain for analysis. A low-power high-data duty-cycled impulse-radio ultra-wideband (IR-UWB) transmitter is designed and implemented using the standard CMOS process. Another focus of this dissertation is the design of a reverse electrowetting-on-dielectric (REWOD) based energy harvesting circuit for wearable sensor applications which is capable of generating a very low-frequency signal from motion activity such a walking, running, jogging, etc. A commercial off-the-shelf (COTS) based and on-chip based energy harvesting circuit is designed for very low-frequency signals. The experimental results show promising progress towards the advancement in the wirelessly powered neuromodulation system and building the self-powered wearable sensor.","abstract_html":"This dissertation is particularly focused on a novel approach of a wirelessly powered neuromodulation system for chronic patients. The inductively coupled transmitter (TX) and receiver (RX) coils are designed through optimization to achieve maximum efficiency. A power management unit (PMU) consisting of a voltage rectifier, voltage regulator along with a stimulation circuitry is also designed to provide pulse stimulation to genetically modified neurons. For continuous health monitoring purposes, the response from the brain due to stimulation needs to be recorded and transmitted wirelessly outside the brain for analysis. A low-power high-data duty-cycled impulse-radio ultra-wideband (IR-UWB) transmitter is designed and implemented using the standard CMOS process. Another focus of this dissertation is the design of a reverse electrowetting-on-dielectric (REWOD) based energy harvesting circuit for wearable sensor applications which is capable of generating a very low-frequency signal from motion activity such a walking, running, jogging, etc. A commercial off-the-shelf (COTS) based and on-chip based energy harvesting circuit is designed for very low-frequency signals. The experimental results show promising progress towards the advancement in the wirelessly powered neuromodulation system and building the self-powered wearable sensor.","abstract_has_math":false,"creators":["Biswas, Dipon Kumar"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Mahbub, Ifana","Mehta, Gayatri","Kaul, Anupama","Namuduri, Kamesh","Eliezer, Oren"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-05","date_published":"2022-05","updated_at":"2026-11-19T08:55:03Z","subjects":["Neuromodulation","Optogenetic","Wireless power transfer (WPT)","Headstage","Power transfer efficiency (PTE)","Light emitting diodes","CMOS process","Bandwidth","Wirless communication","Frequency modulation","Charge pumps","Rectifiers."],"languages":["English"],"rights":["Public","Biswas, Dipon Kumar","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_2809","https://digital.library.unt.edu/ark:/67531/metadc1944251/","ark: ark:/67531/metadc1944251"],"render_values":[{"text":"local-cont-no: submission_2809","href":null,"code":true},{"text":"https://digital.library.unt.edu/ark:/67531/metadc1944251/","href":"https://digital.library.unt.edu/ark:/67531/metadc1944251/","code":true},{"text":"ark: ark:/67531/metadc1944251","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.12794/metadc1944251","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.12794/metadc1944251","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc1944251","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Mahbub, Ifana","Mehta, Gayatri","Kaul, Anupama","Namuduri, Kamesh","Eliezer, Oren"]},{"key":"dc:creator","label":"Author","values":["Biswas, Dipon Kumar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-05"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Neuromodulation","Optogenetic","Wireless power transfer (WPT)","Headstage","Power transfer efficiency (PTE)","Light emitting diodes","CMOS process","Bandwidth","Wirless communication","Frequency modulation","Charge pumps","Rectifiers."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Biswas, Dipon Kumar","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_2809","doi: 10.12794/metadc1944251","https://digital.library.unt.edu/ark:/67531/metadc1944251/","ark: ark:/67531/metadc1944251"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This dissertation is particularly focused on a novel approach of a wirelessly powered neuromodulation system for chronic patients. The inductively coupled transmitter (TX) and receiver (RX) coils are designed through optimization to achieve maximum efficiency. A power management unit (PMU) consisting of a voltage rectifier, voltage regulator along with a stimulation circuitry is also designed to provide pulse stimulation to genetically modified neurons. For continuous health monitoring purposes, the response from the brain due to stimulation needs to be recorded and transmitted wirelessly outside the brain for analysis. A low-power high-data duty-cycled impulse-radio ultra-wideband (IR-UWB) transmitter is designed and implemented using the standard CMOS process. Another focus of this dissertation is the design of a reverse electrowetting-on-dielectric (REWOD) based energy harvesting circuit for wearable sensor applications which is capable of generating a very low-frequency signal from motion activity such a walking, running, jogging, etc. A commercial off-the-shelf (COTS) based and on-chip based energy harvesting circuit is designed for very low-frequency signals. The experimental results show promising progress towards the advancement in the wirelessly powered neuromodulation system and building the self-powered wearable sensor."]},{"key":"dc:format","label":"Dc Format","values":["Text"]},{"key":"dc:title","label":"Title","values":["Wireless Power Transfer and Power Management Unit Integrated with Low-Power IR-UWB Transmitter for Neuromodulation and Self-Powered Sensor Applications"]}]}],"canonical_facts":{"dc:contributor":["Mahbub, Ifana","Mehta, Gayatri","Kaul, Anupama","Namuduri, Kamesh","Eliezer, Oren"],"dc:creator":["Biswas, Dipon Kumar"],"dc:date":["2022-05"],"dc:description":["This dissertation is particularly focused on a novel approach of a wirelessly powered neuromodulation system for chronic patients. The inductively coupled transmitter (TX) and receiver (RX) coils are designed through optimization to achieve maximum efficiency. A power management unit (PMU) consisting of a voltage rectifier, voltage regulator along with a stimulation circuitry is also designed to provide pulse stimulation to genetically modified neurons. For continuous health monitoring purposes, the response from the brain due to stimulation needs to be recorded and transmitted wirelessly outside the brain for analysis. A low-power high-data duty-cycled impulse-radio ultra-wideband (IR-UWB) transmitter is designed and implemented using the standard CMOS process. Another focus of this dissertation is the design of a reverse electrowetting-on-dielectric (REWOD) based energy harvesting circuit for wearable sensor applications which is capable of generating a very low-frequency signal from motion activity such a walking, running, jogging, etc. A commercial off-the-shelf (COTS) based and on-chip based energy harvesting circuit is designed for very low-frequency signals. The experimental results show promising progress towards the advancement in the wirelessly powered neuromodulation system and building the self-powered wearable sensor."],"dc:format":["Text"],"dc:identifier":["local-cont-no: submission_2809","doi: 10.12794/metadc1944251","https://digital.library.unt.edu/ark:/67531/metadc1944251/","ark: ark:/67531/metadc1944251"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Biswas, Dipon Kumar","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"dc:subject":["Neuromodulation","Optogenetic","Wireless power transfer (WPT)","Headstage","Power transfer efficiency (PTE)","Light emitting diodes","CMOS process","Bandwidth","Wirless communication","Frequency modulation","Charge pumps","Rectifiers."],"dc:title":["Wireless Power Transfer and Power Management Unit Integrated with Low-Power IR-UWB Transmitter for Neuromodulation and Self-Powered Sensor Applications"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:55:03Z"}