{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc1944354"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc1944354","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Low-Power Biopotential Signal Acquisition System for Biomedical Applications","abstract":"The key requirements of a reliable neural signal recording system include low power to support long-term monitoring, low noise, minimum tissue damage, and wireless transmission. The neural spikes are also detected and sorted on-chip/off-chip to implement closed-loop neuromodulation in a high channel count setup. All these features together constitute an empirical neural recording system for neuroscience research. In this prospectus, we propose to develop a neural signal acquisition system with wireless transmission and feature extraction. We start by designing a prototype entirely built with commercial-off-the-shelf components, which includes recording and wireless transmission of synthetic neural data and feature extraction. We then conduct the CMOS implementation of the low-power multi-channel neural signal recording read-out circuit, which enables the in-vivo recording with a small form factor. Another direction of this thesis is to design a self-powered motion tracking read-out circuit for wearable sensors. As the wearable industry continues to advance, the need for self-powered medical devices is growing significantly. In this line of research, we propose a self-powered motion sensor based on reverse electrowetting-on-dielectric (REWOD) with low-power integrated electronics for remotely monitoring health conditions. We design the low-power read-out circuit for a wide range of input charges, which is generated from the REWOD sensor.","abstract_html":"The key requirements of a reliable neural signal recording system include low power to support long-term monitoring, low noise, minimum tissue damage, and wireless transmission. The neural spikes are also detected and sorted on-chip/off-chip to implement closed-loop neuromodulation in a high channel count setup. All these features together constitute an empirical neural recording system for neuroscience research. In this prospectus, we propose to develop a neural signal acquisition system with wireless transmission and feature extraction. We start by designing a prototype entirely built with commercial-off-the-shelf components, which includes recording and wireless transmission of synthetic neural data and feature extraction. We then conduct the CMOS implementation of the low-power multi-channel neural signal recording read-out circuit, which enables the in-vivo recording with a small form factor. Another direction of this thesis is to design a self-powered motion tracking read-out circuit for wearable sensors. As the wearable industry continues to advance, the need for self-powered medical devices is growing significantly. In this line of research, we propose a self-powered motion sensor based on reverse electrowetting-on-dielectric (REWOD) with low-power integrated electronics for remotely monitoring health conditions. We design the low-power read-out circuit for a wide range of input charges, which is generated from the REWOD sensor.","abstract_has_math":false,"creators":["Tasneem, Nishat Tarannum"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Mahbub, Ifana","Mehta, Gayatri","Namuduri, Kamesh","Kaul, Anupama","Qu, WenChao"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-05","date_published":"2022-05","updated_at":"2026-11-19T08:55:03Z","subjects":["Neural signal recording","low-power","multi-channel","chopper amplifier","SAR-ADC","reconfigurability","feature extraction","motion sensor","low-frequency bandwidth."],"languages":["English"],"rights":["Public","Tasneem, Nishat Tarannum","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_2922","https://digital.library.unt.edu/ark:/67531/metadc1944354/","ark: ark:/67531/metadc1944354"],"render_values":[{"text":"local-cont-no: submission_2922","href":null,"code":true},{"text":"https://digital.library.unt.edu/ark:/67531/metadc1944354/","href":"https://digital.library.unt.edu/ark:/67531/metadc1944354/","code":true},{"text":"ark: ark:/67531/metadc1944354","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.12794/metadc1944354","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.12794/metadc1944354","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc1944354","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Mahbub, Ifana","Mehta, Gayatri","Namuduri, Kamesh","Kaul, Anupama","Qu, WenChao"]},{"key":"dc:creator","label":"Author","values":["Tasneem, Nishat Tarannum"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-05"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Neural signal recording","low-power","multi-channel","chopper amplifier","SAR-ADC","reconfigurability","feature extraction","motion sensor","low-frequency bandwidth."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Tasneem, Nishat Tarannum","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_2922","doi: 10.12794/metadc1944354","https://digital.library.unt.edu/ark:/67531/metadc1944354/","ark: ark:/67531/metadc1944354"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The key requirements of a reliable neural signal recording system include low power to support long-term monitoring, low noise, minimum tissue damage, and wireless transmission. The neural spikes are also detected and sorted on-chip/off-chip to implement closed-loop neuromodulation in a high channel count setup. All these features together constitute an empirical neural recording system for neuroscience research. In this prospectus, we propose to develop a neural signal acquisition system with wireless transmission and feature extraction. We start by designing a prototype entirely built with commercial-off-the-shelf components, which includes recording and wireless transmission of synthetic neural data and feature extraction. We then conduct the CMOS implementation of the low-power multi-channel neural signal recording read-out circuit, which enables the in-vivo recording with a small form factor. Another direction of this thesis is to design a self-powered motion tracking read-out circuit for wearable sensors. As the wearable industry continues to advance, the need for self-powered medical devices is growing significantly. In this line of research, we propose a self-powered motion sensor based on reverse electrowetting-on-dielectric (REWOD) with low-power integrated electronics for remotely monitoring health conditions. We design the low-power read-out circuit for a wide range of input charges, which is generated from the REWOD sensor."]},{"key":"dc:format","label":"Dc Format","values":["Text"]},{"key":"dc:title","label":"Title","values":["Low-Power Biopotential Signal Acquisition System for Biomedical Applications"]}]}],"canonical_facts":{"dc:contributor":["Mahbub, Ifana","Mehta, Gayatri","Namuduri, Kamesh","Kaul, Anupama","Qu, WenChao"],"dc:creator":["Tasneem, Nishat Tarannum"],"dc:date":["2022-05"],"dc:description":["The key requirements of a reliable neural signal recording system include low power to support long-term monitoring, low noise, minimum tissue damage, and wireless transmission. The neural spikes are also detected and sorted on-chip/off-chip to implement closed-loop neuromodulation in a high channel count setup. All these features together constitute an empirical neural recording system for neuroscience research. In this prospectus, we propose to develop a neural signal acquisition system with wireless transmission and feature extraction. We start by designing a prototype entirely built with commercial-off-the-shelf components, which includes recording and wireless transmission of synthetic neural data and feature extraction. We then conduct the CMOS implementation of the low-power multi-channel neural signal recording read-out circuit, which enables the in-vivo recording with a small form factor. Another direction of this thesis is to design a self-powered motion tracking read-out circuit for wearable sensors. As the wearable industry continues to advance, the need for self-powered medical devices is growing significantly. In this line of research, we propose a self-powered motion sensor based on reverse electrowetting-on-dielectric (REWOD) with low-power integrated electronics for remotely monitoring health conditions. We design the low-power read-out circuit for a wide range of input charges, which is generated from the REWOD sensor."],"dc:format":["Text"],"dc:identifier":["local-cont-no: submission_2922","doi: 10.12794/metadc1944354","https://digital.library.unt.edu/ark:/67531/metadc1944354/","ark: ark:/67531/metadc1944354"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Tasneem, Nishat Tarannum","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"dc:subject":["Neural signal recording","low-power","multi-channel","chopper amplifier","SAR-ADC","reconfigurability","feature extraction","motion sensor","low-frequency bandwidth."],"dc:title":["Low-Power Biopotential Signal Acquisition System for Biomedical Applications"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:55:03Z"}