{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc2415974"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc2415974","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Bio-Based Fatty Acid Synthesization from Recycling Waste Cooking Oil and Its Applications","abstract":"Waste cooking oils (WCOs) are generated every day in the world, and a large amount of WCOs are disposed in landfills as solid wastes. It would cause serious problems. In this study, a novel method for recycling WCO has been developed based on hydrolysis and hydrogenation processes. The final products are value-added and melting point-adjustable WCO fatty acid (WCOFA) phase change materials (PCMs). Moreover, chemical structures characterization and thermal properties investigation have been conducted to discover the chemical structure-thermal properties relations. Building energy modeling was conducted with the properties of WCOFA. With WCOFAs integrated in the building structural insulated panel (SIP), the total yearly energy consumption (EC) would be reduced up to 18.76% based on the geometry of ZOE lab in UNT and the weather data of DFW area. A small-scale experimental building was used to examine the insulation performance of PCMs. It showed that the EC was reduced by 14.80% and cooling system running time was decreased by 12.94%. In addition, the PCM integrated firefighting gloves were tested to discover the thermal insulation performance of PCMs. It was found that the overall thermal protection time could be extended by 2-5 times in conductive tests and around 1.5 times in the radiant/convective tests with 1-mm-thick PCM layer in all six brands of gloves. With the increased moisture content levels, the thermal protection time could be extended 1.4-2.1 times in conductive tests and 1.2-1.5 times in radiant/convective tests.","abstract_html":"Waste cooking oils (WCOs) are generated every day in the world, and a large amount of WCOs are disposed in landfills as solid wastes. It would cause serious problems. In this study, a novel method for recycling WCO has been developed based on hydrolysis and hydrogenation processes. The final products are value-added and melting point-adjustable WCO fatty acid (WCOFA) phase change materials (PCMs). Moreover, chemical structures characterization and thermal properties investigation have been conducted to discover the chemical structure-thermal properties relations. Building energy modeling was conducted with the properties of WCOFA. With WCOFAs integrated in the building structural insulated panel (SIP), the total yearly energy consumption (EC) would be reduced up to 18.76% based on the geometry of ZOE lab in UNT and the weather data of DFW area. A small-scale experimental building was used to examine the insulation performance of PCMs. It showed that the EC was reduced by 14.80% and cooling system running time was decreased by 12.94%. In addition, the PCM integrated firefighting gloves were tested to discover the thermal insulation performance of PCMs. It was found that the overall thermal protection time could be extended by 2-5 times in conductive tests and around 1.5 times in the radiant/convective tests with 1-mm-thick PCM layer in all six brands of gloves. With the increased moisture content levels, the thermal protection time could be extended 1.4-2.1 times in conductive tests and 1.2-1.5 times in radiant/convective tests.","abstract_has_math":false,"creators":["Wang, Xun"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Shi, Sheldon Q","Zhao, Weihuan","Nasrazadani, Seifollah","Choi, Taeyul T","Huang, Zhenhua"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-12","date_published":"2024-12","updated_at":"2026-11-19T08:55:14Z","subjects":["Mechanical Engineering","Fatty Acid Synthesization","Waste cooking oils","energy consumption"],"languages":["English"],"rights":["Public","Wang, Xun","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_4077","https://digital.library.unt.edu/ark:/67531/metadc2415974/","ark: ark:/67531/metadc2415974"],"render_values":[{"text":"local-cont-no: submission_4077","href":null,"code":true},{"text":"https://digital.library.unt.edu/ark:/67531/metadc2415974/","href":"https://digital.library.unt.edu/ark:/67531/metadc2415974/","code":true},{"text":"ark: ark:/67531/metadc2415974","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.12794/metadc2415974","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.12794/metadc2415974","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc2415974","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Shi, Sheldon Q","Zhao, Weihuan","Nasrazadani, Seifollah","Choi, Taeyul T","Huang, Zhenhua"]},{"key":"dc:creator","label":"Author","values":["Wang, Xun"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024-12"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","Fatty Acid Synthesization","Waste cooking oils","energy consumption"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Wang, Xun","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_4077","doi: 10.12794/metadc2415974","https://digital.library.unt.edu/ark:/67531/metadc2415974/","ark: ark:/67531/metadc2415974"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Waste cooking oils (WCOs) are generated every day in the world, and a large amount of WCOs are disposed in landfills as solid wastes. It would cause serious problems. In this study, a novel method for recycling WCO has been developed based on hydrolysis and hydrogenation processes. The final products are value-added and melting point-adjustable WCO fatty acid (WCOFA) phase change materials (PCMs). Moreover, chemical structures characterization and thermal properties investigation have been conducted to discover the chemical structure-thermal properties relations. Building energy modeling was conducted with the properties of WCOFA. With WCOFAs integrated in the building structural insulated panel (SIP), the total yearly energy consumption (EC) would be reduced up to 18.76% based on the geometry of ZOE lab in UNT and the weather data of DFW area. A small-scale experimental building was used to examine the insulation performance of PCMs. It showed that the EC was reduced by 14.80% and cooling system running time was decreased by 12.94%. In addition, the PCM integrated firefighting gloves were tested to discover the thermal insulation performance of PCMs. It was found that the overall thermal protection time could be extended by 2-5 times in conductive tests and around 1.5 times in the radiant/convective tests with 1-mm-thick PCM layer in all six brands of gloves. With the increased moisture content levels, the thermal protection time could be extended 1.4-2.1 times in conductive tests and 1.2-1.5 times in radiant/convective tests."]},{"key":"dc:format","label":"Dc Format","values":["Text"]},{"key":"dc:title","label":"Title","values":["Bio-Based Fatty Acid Synthesization from Recycling Waste Cooking Oil and Its Applications"]}]}],"canonical_facts":{"dc:contributor":["Shi, Sheldon Q","Zhao, Weihuan","Nasrazadani, Seifollah","Choi, Taeyul T","Huang, Zhenhua"],"dc:creator":["Wang, Xun"],"dc:date":["2024-12"],"dc:description":["Waste cooking oils (WCOs) are generated every day in the world, and a large amount of WCOs are disposed in landfills as solid wastes. It would cause serious problems. In this study, a novel method for recycling WCO has been developed based on hydrolysis and hydrogenation processes. The final products are value-added and melting point-adjustable WCO fatty acid (WCOFA) phase change materials (PCMs). Moreover, chemical structures characterization and thermal properties investigation have been conducted to discover the chemical structure-thermal properties relations. Building energy modeling was conducted with the properties of WCOFA. With WCOFAs integrated in the building structural insulated panel (SIP), the total yearly energy consumption (EC) would be reduced up to 18.76% based on the geometry of ZOE lab in UNT and the weather data of DFW area. A small-scale experimental building was used to examine the insulation performance of PCMs. It showed that the EC was reduced by 14.80% and cooling system running time was decreased by 12.94%. In addition, the PCM integrated firefighting gloves were tested to discover the thermal insulation performance of PCMs. It was found that the overall thermal protection time could be extended by 2-5 times in conductive tests and around 1.5 times in the radiant/convective tests with 1-mm-thick PCM layer in all six brands of gloves. With the increased moisture content levels, the thermal protection time could be extended 1.4-2.1 times in conductive tests and 1.2-1.5 times in radiant/convective tests."],"dc:format":["Text"],"dc:identifier":["local-cont-no: submission_4077","doi: 10.12794/metadc2415974","https://digital.library.unt.edu/ark:/67531/metadc2415974/","ark: ark:/67531/metadc2415974"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Wang, Xun","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"dc:subject":["Mechanical Engineering","Fatty Acid Synthesization","Waste cooking oils","energy consumption"],"dc:title":["Bio-Based Fatty Acid Synthesization from Recycling Waste Cooking Oil and Its Applications"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:55:14Z"}