{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc2443364"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc2443364","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Portable Mass Spectrometry for the Trace Detection of Volatile Organic Compounds in Environmental and Biological Applications","abstract":"Volatile organic compounds (VOCs) have the potential to pose significant health risks to individuals that are exposed and can accumulate overtime within the atmosphere of an enclosed space. VOCs are also the byproducts of some metabolic processes and in some cases, are produced as the body’s response to a disease or infection. Some diseases and infections produce disease specific VOCs that allows for a noninvasive diagnosis using breath biopsies. Portable mass spectrometry instruments have proven advantageous in detecting and monitoring these VOCs as mass spectrometry it is a prominent analytical technique known for its ability to discriminate gas-phase ions based on their mass-to-charge ratios (m/z). Membrane Inlet Mass Spectrometry (MIMS) implements a semipermeable tubular membrane that serves as a barrier between the atmospheric pressure environment and the vacuum pressure environment of the mass spectrometer, allowing for selective analyte passage. Substrate Capture Mass Spectrometry (SubCap-MS) implements an interchangeable substrate capture sample chamber that utilizes carbon adsorbents to capture chemistry in a gas-phase sample. MIMS and SubCap-MS are both portable detection systems capable of producing reliable data with rapid response times and both allow for continuous sampling as well as minimal sample preparation which eliminates the need for complicated analyte introduction techniques. Both the MIMS and SubCap-MS instruments are field portable, rapid, and selective analytical techniques that are primarily used for analyzing ambient air on-site and in real-time.","abstract_html":"Volatile organic compounds (VOCs) have the potential to pose significant health risks to individuals that are exposed and can accumulate overtime within the atmosphere of an enclosed space. VOCs are also the byproducts of some metabolic processes and in some cases, are produced as the body’s response to a disease or infection. Some diseases and infections produce disease specific VOCs that allows for a noninvasive diagnosis using breath biopsies. Portable mass spectrometry instruments have proven advantageous in detecting and monitoring these VOCs as mass spectrometry it is a prominent analytical technique known for its ability to discriminate gas-phase ions based on their mass-to-charge ratios (m/z). Membrane Inlet Mass Spectrometry (MIMS) implements a semipermeable tubular membrane that serves as a barrier between the atmospheric pressure environment and the vacuum pressure environment of the mass spectrometer, allowing for selective analyte passage. Substrate Capture Mass Spectrometry (SubCap-MS) implements an interchangeable substrate capture sample chamber that utilizes carbon adsorbents to capture chemistry in a gas-phase sample. MIMS and SubCap-MS are both portable detection systems capable of producing reliable data with rapid response times and both allow for continuous sampling as well as minimal sample preparation which eliminates the need for complicated analyte introduction techniques. Both the MIMS and SubCap-MS instruments are field portable, rapid, and selective analytical techniques that are primarily used for analyzing ambient air on-site and in real-time.","abstract_has_math":false,"creators":["Juel, Lauren Ashlee' Marie"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Verbeck, Guido F.","Marshall, Paul","Lund, Amie K.","Williams, Kristina C.","Golden, Teresa Diane, 1963-"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-05","date_published":"2025-05","updated_at":"2026-11-19T08:55:14Z","subjects":["volatile organic compounds","health risks","breath biopsies","portable mass spectrometry"],"languages":["English"],"rights":["Public","Juel, Lauren Ashlee' Marie","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_4359","https://digital.library.unt.edu/ark:/67531/metadc2443364/","ark: ark:/67531/metadc2443364"],"render_values":[{"text":"local-cont-no: submission_4359","href":null,"code":true},{"text":"https://digital.library.unt.edu/ark:/67531/metadc2443364/","href":"https://digital.library.unt.edu/ark:/67531/metadc2443364/","code":true},{"text":"ark: ark:/67531/metadc2443364","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.12794/metadc2443364","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.12794/metadc2443364","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc2443364","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Verbeck, Guido F.","Marshall, Paul","Lund, Amie K.","Williams, Kristina C.","Golden, Teresa Diane, 1963-"]},{"key":"dc:creator","label":"Author","values":["Juel, Lauren Ashlee' Marie"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-05"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["volatile organic compounds","health risks","breath biopsies","portable mass spectrometry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Juel, Lauren Ashlee' Marie","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_4359","doi: 10.12794/metadc2443364","https://digital.library.unt.edu/ark:/67531/metadc2443364/","ark: ark:/67531/metadc2443364"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Volatile organic compounds (VOCs) have the potential to pose significant health risks to individuals that are exposed and can accumulate overtime within the atmosphere of an enclosed space. VOCs are also the byproducts of some metabolic processes and in some cases, are produced as the body’s response to a disease or infection. Some diseases and infections produce disease specific VOCs that allows for a noninvasive diagnosis using breath biopsies. Portable mass spectrometry instruments have proven advantageous in detecting and monitoring these VOCs as mass spectrometry it is a prominent analytical technique known for its ability to discriminate gas-phase ions based on their mass-to-charge ratios (m/z). Membrane Inlet Mass Spectrometry (MIMS) implements a semipermeable tubular membrane that serves as a barrier between the atmospheric pressure environment and the vacuum pressure environment of the mass spectrometer, allowing for selective analyte passage. Substrate Capture Mass Spectrometry (SubCap-MS) implements an interchangeable substrate capture sample chamber that utilizes carbon adsorbents to capture chemistry in a gas-phase sample. MIMS and SubCap-MS are both portable detection systems capable of producing reliable data with rapid response times and both allow for continuous sampling as well as minimal sample preparation which eliminates the need for complicated analyte introduction techniques. Both the MIMS and SubCap-MS instruments are field portable, rapid, and selective analytical techniques that are primarily used for analyzing ambient air on-site and in real-time."]},{"key":"dc:format","label":"Dc Format","values":["Text"]},{"key":"dc:title","label":"Title","values":["Portable Mass Spectrometry for the Trace Detection of Volatile Organic Compounds in Environmental and Biological Applications"]}]}],"canonical_facts":{"dc:contributor":["Verbeck, Guido F.","Marshall, Paul","Lund, Amie K.","Williams, Kristina C.","Golden, Teresa Diane, 1963-"],"dc:creator":["Juel, Lauren Ashlee' Marie"],"dc:date":["2025-05"],"dc:description":["Volatile organic compounds (VOCs) have the potential to pose significant health risks to individuals that are exposed and can accumulate overtime within the atmosphere of an enclosed space. VOCs are also the byproducts of some metabolic processes and in some cases, are produced as the body’s response to a disease or infection. Some diseases and infections produce disease specific VOCs that allows for a noninvasive diagnosis using breath biopsies. Portable mass spectrometry instruments have proven advantageous in detecting and monitoring these VOCs as mass spectrometry it is a prominent analytical technique known for its ability to discriminate gas-phase ions based on their mass-to-charge ratios (m/z). Membrane Inlet Mass Spectrometry (MIMS) implements a semipermeable tubular membrane that serves as a barrier between the atmospheric pressure environment and the vacuum pressure environment of the mass spectrometer, allowing for selective analyte passage. Substrate Capture Mass Spectrometry (SubCap-MS) implements an interchangeable substrate capture sample chamber that utilizes carbon adsorbents to capture chemistry in a gas-phase sample. MIMS and SubCap-MS are both portable detection systems capable of producing reliable data with rapid response times and both allow for continuous sampling as well as minimal sample preparation which eliminates the need for complicated analyte introduction techniques. Both the MIMS and SubCap-MS instruments are field portable, rapid, and selective analytical techniques that are primarily used for analyzing ambient air on-site and in real-time."],"dc:format":["Text"],"dc:identifier":["local-cont-no: submission_4359","doi: 10.12794/metadc2443364","https://digital.library.unt.edu/ark:/67531/metadc2443364/","ark: ark:/67531/metadc2443364"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Juel, Lauren Ashlee' Marie","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"dc:subject":["volatile organic compounds","health risks","breath biopsies","portable mass spectrometry"],"dc:title":["Portable Mass Spectrometry for the Trace Detection of Volatile Organic Compounds in Environmental and Biological Applications"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:55:14Z"}