{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc2652567"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc2652567","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Evaluation of an Alternate Method of Calculating Anaerobic Contribution in Exercise","abstract":"This dissertation refines AOD_alt as a practical alternative to the gold-standard accumulated oxygen deficit (AOD) for estimating anaerobic contribution and capacity. Because AOD_alt had not been validated in hypoxia despite its use in hypoxic studies, Study 1 evaluated its validity against AOD. Fifteen participants performed 6 min of heavy-intensity cycle ergometer exercise in normoxia and hypoxia (FIO2 = 15% and 12%). AOD_alt correlated strongly with AOD (r = 0.82–0.87). Six participants performed severe-intensity tests to exhaustion; correlations were strong in normoxia and moderate hypoxia (r = 0.77–0.92) but weak in extreme hypoxia (r = 0.27). These results establish AOD_alt validity in normoxia and moderate hypoxia. Study 1 calculations incorporated the V̇O2 slow component area, prompting Study 2 to examine whether the slow component relates to glycolytic contribution. In 20 participants during severe-intensity cycling, glycolytic contribution correlated with the slow component (r = 0.69 for 3–6 min; r = 0.75 for 6–9 min). These results confirm the slow component area should be included as excess oxygen cost when calculating MAOD in validation studies. Because varying values of the O2–Eq–Lac have been used and sex-specific values had never been determined, the purpose of Study 3 was to derive these factors. Twenty-five trained runners performed 6-min severe treadmill runs. The O2–Eq–Lac was 3.6 ± 0.3 mL·kg⁻1·mM⁻1 in women and 3.2 ± 0.2 mL·kg⁻1·mM⁻1 in men (p < 0.01, Cohen’s d = 1.70). This novel finding indicates sex-specific conversion factors should be used when calculating glycolytic contribution and anaerobic capacity in mixed-sex samples. Collectively, these studies validate a practical alternative to AOD, provide mechanistic support for the slow component in glycolytic estimates, and refine the conversion factor for sex differences. These findings advance the accurate measurement of anaerobic contribution and capacity across intensities, conditions, and sexes.","abstract_html":"This dissertation refines AOD_alt as a practical alternative to the gold-standard accumulated oxygen deficit (AOD) for estimating anaerobic contribution and capacity. Because AOD_alt had not been validated in hypoxia despite its use in hypoxic studies, Study 1 evaluated its validity against AOD. Fifteen participants performed 6 min of heavy-intensity cycle ergometer exercise in normoxia and hypoxia (FIO2 = 15% and 12%). AOD_alt correlated strongly with AOD (r = 0.82–0.87). Six participants performed severe-intensity tests to exhaustion; correlations were strong in normoxia and moderate hypoxia (r = 0.77–0.92) but weak in extreme hypoxia (r = 0.27). These results establish AOD_alt validity in normoxia and moderate hypoxia. Study 1 calculations incorporated the V̇O2 slow component area, prompting Study 2 to examine whether the slow component relates to glycolytic contribution. In 20 participants during severe-intensity cycling, glycolytic contribution correlated with the slow component (r = 0.69 for 3–6 min; r = 0.75 for 6–9 min). These results confirm the slow component area should be included as excess oxygen cost when calculating MAOD in validation studies. Because varying values of the O2–Eq–Lac have been used and sex-specific values had never been determined, the purpose of Study 3 was to derive these factors. Twenty-five trained runners performed 6-min severe treadmill runs. The O2–Eq–Lac was 3.6 ± 0.3 mL·kg⁻1·mM⁻1 in women and 3.2 ± 0.2 mL·kg⁻1·mM⁻1 in men (p &lt; 0.01, Cohen’s d = 1.70). This novel finding indicates sex-specific conversion factors should be used when calculating glycolytic contribution and anaerobic capacity in mixed-sex samples. Collectively, these studies validate a practical alternative to AOD, provide mechanistic support for the slow component in glycolytic estimates, and refine the conversion factor for sex differences. These findings advance the accurate measurement of anaerobic contribution and capacity across intensities, conditions, and sexes.","abstract_has_math":false,"creators":["Shaw, Austin Brian 1995-"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Hill, David W.","Deemer, Sarah E.","Caldwell, Lydia K."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-07","date_published":"2026-07","updated_at":"2026-11-19T08:55:57Z","subjects":["Health Sciences, General","glycolytic estimates","anaerobic contribution"],"languages":["English"],"rights":["Public","Shaw, Austin Brian 1995-","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_5081","ark: ark:/67531/metadc2652567"],"render_values":[{"text":"local-cont-no: submission_5081","href":null,"code":true},{"text":"ark: ark:/67531/metadc2652567","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digital.library.unt.edu/ark:/67531/metadc2652567/","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digital.library.unt.edu/ark:/67531/metadc2652567/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc2652567","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Hill, David W.","Deemer, Sarah E.","Caldwell, Lydia K."]},{"key":"dc:creator","label":"Author","values":["Shaw, Austin Brian 1995-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026-07"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Health Sciences, General","glycolytic estimates","anaerobic contribution"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Shaw, Austin Brian 1995-","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_5081","https://digital.library.unt.edu/ark:/67531/metadc2652567/","ark: ark:/67531/metadc2652567"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This dissertation refines AOD_alt as a practical alternative to the gold-standard accumulated oxygen deficit (AOD) for estimating anaerobic contribution and capacity. Because AOD_alt had not been validated in hypoxia despite its use in hypoxic studies, Study 1 evaluated its validity against AOD. Fifteen participants performed 6 min of heavy-intensity cycle ergometer exercise in normoxia and hypoxia (FIO2 = 15% and 12%). AOD_alt correlated strongly with AOD (r = 0.82–0.87). Six participants performed severe-intensity tests to exhaustion; correlations were strong in normoxia and moderate hypoxia (r = 0.77–0.92) but weak in extreme hypoxia (r = 0.27). These results establish AOD_alt validity in normoxia and moderate hypoxia. Study 1 calculations incorporated the V̇O2 slow component area, prompting Study 2 to examine whether the slow component relates to glycolytic contribution. In 20 participants during severe-intensity cycling, glycolytic contribution correlated with the slow component (r = 0.69 for 3–6 min; r = 0.75 for 6–9 min). These results confirm the slow component area should be included as excess oxygen cost when calculating MAOD in validation studies. Because varying values of the O2–Eq–Lac have been used and sex-specific values had never been determined, the purpose of Study 3 was to derive these factors. Twenty-five trained runners performed 6-min severe treadmill runs. The O2–Eq–Lac was 3.6 ± 0.3 mL·kg⁻1·mM⁻1 in women and 3.2 ± 0.2 mL·kg⁻1·mM⁻1 in men (p < 0.01, Cohen’s d = 1.70). This novel finding indicates sex-specific conversion factors should be used when calculating glycolytic contribution and anaerobic capacity in mixed-sex samples. Collectively, these studies validate a practical alternative to AOD, provide mechanistic support for the slow component in glycolytic estimates, and refine the conversion factor for sex differences. These findings advance the accurate measurement of anaerobic contribution and capacity across intensities, conditions, and sexes."]},{"key":"dc:format","label":"Dc Format","values":["Text"]},{"key":"dc:title","label":"Title","values":["Evaluation of an Alternate Method of Calculating Anaerobic Contribution in Exercise"]}]}],"canonical_facts":{"dc:contributor":["Hill, David W.","Deemer, Sarah E.","Caldwell, Lydia K."],"dc:creator":["Shaw, Austin Brian 1995-"],"dc:date":["2026-07"],"dc:description":["This dissertation refines AOD_alt as a practical alternative to the gold-standard accumulated oxygen deficit (AOD) for estimating anaerobic contribution and capacity. Because AOD_alt had not been validated in hypoxia despite its use in hypoxic studies, Study 1 evaluated its validity against AOD. Fifteen participants performed 6 min of heavy-intensity cycle ergometer exercise in normoxia and hypoxia (FIO2 = 15% and 12%). AOD_alt correlated strongly with AOD (r = 0.82–0.87). Six participants performed severe-intensity tests to exhaustion; correlations were strong in normoxia and moderate hypoxia (r = 0.77–0.92) but weak in extreme hypoxia (r = 0.27). These results establish AOD_alt validity in normoxia and moderate hypoxia. Study 1 calculations incorporated the V̇O2 slow component area, prompting Study 2 to examine whether the slow component relates to glycolytic contribution. In 20 participants during severe-intensity cycling, glycolytic contribution correlated with the slow component (r = 0.69 for 3–6 min; r = 0.75 for 6–9 min). These results confirm the slow component area should be included as excess oxygen cost when calculating MAOD in validation studies. Because varying values of the O2–Eq–Lac have been used and sex-specific values had never been determined, the purpose of Study 3 was to derive these factors. Twenty-five trained runners performed 6-min severe treadmill runs. The O2–Eq–Lac was 3.6 ± 0.3 mL·kg⁻1·mM⁻1 in women and 3.2 ± 0.2 mL·kg⁻1·mM⁻1 in men (p < 0.01, Cohen’s d = 1.70). This novel finding indicates sex-specific conversion factors should be used when calculating glycolytic contribution and anaerobic capacity in mixed-sex samples. Collectively, these studies validate a practical alternative to AOD, provide mechanistic support for the slow component in glycolytic estimates, and refine the conversion factor for sex differences. These findings advance the accurate measurement of anaerobic contribution and capacity across intensities, conditions, and sexes."],"dc:format":["Text"],"dc:identifier":["local-cont-no: submission_5081","https://digital.library.unt.edu/ark:/67531/metadc2652567/","ark: ark:/67531/metadc2652567"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Shaw, Austin Brian 1995-","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"dc:subject":["Health Sciences, General","glycolytic estimates","anaerobic contribution"],"dc:title":["Evaluation of an Alternate Method of Calculating Anaerobic Contribution in Exercise"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:55:57Z"}