{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc277845"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc277845","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Investigation of Ultratrace Metallic and Organic Contaminants in Semiconductor Processing Environments","abstract":"Detection of ultratrace levels of metallic ion impurities in hydrofluoric acid solutions and alkaline hydrogen peroxide solution was demonstrated using a silicon-based sensing electrode. The sensor's operation principle is based on direct measurements of the silicon open-circuit potential shift generated by the interaction between metallic ions and the silicon-based sensing surface. The new sensor can have practical applications in the on-line monitoring of microelectronic chemical processing. The detection of Ag+ content in KODAK waste water was carried out successfully by this novel sensor. Trace levels of organic impurities in the hydrofluoric acid solutions and in the cleanroom air were characterized by multiple internal reflection infrared spectroscopy (MIRIS) using an organics probe prepared directly from a regular silicon wafer.","abstract_html":"Detection of ultratrace levels of metallic ion impurities in hydrofluoric acid solutions and alkaline hydrogen peroxide solution was demonstrated using a silicon-based sensing electrode. The sensor&#x27;s operation principle is based on direct measurements of the silicon open-circuit potential shift generated by the interaction between metallic ions and the silicon-based sensing surface. The new sensor can have practical applications in the on-line monitoring of microelectronic chemical processing. The detection of Ag+ content in KODAK waste water was carried out successfully by this novel sensor. Trace levels of organic impurities in the hydrofluoric acid solutions and in the cleanroom air were characterized by multiple internal reflection infrared spectroscopy (MIRIS) using an organics probe prepared directly from a regular silicon wafer.","abstract_has_math":false,"creators":["Xu, Fei, 1971-"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Chyan, Oliver Ming-Ren","Acree, William E. (William Eugene)"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1997,"date_issued":"1997-05","date_published":"1997-05","updated_at":"2026-11-19T08:50:51Z","subjects":["Semiconductors -- Design and construction.","Contamination (Technology)","metallic ion impurities","silicon-based sensing electrode"],"languages":["English"],"rights":["Public","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved.","Xu, Fei, 1971-"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["call-no: 379 N81 no.7382","local-cont-no: 1002656548-xu","untcat: b2041269","ark: ark:/67531/metadc277845"],"render_values":[{"text":"call-no: 379 N81 no.7382","href":null,"code":true},{"text":"local-cont-no: 1002656548-xu","href":null,"code":true},{"text":"untcat: b2041269","href":null,"code":true},{"text":"ark: ark:/67531/metadc277845","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digital.library.unt.edu/ark:/67531/metadc277845/","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digital.library.unt.edu/ark:/67531/metadc277845/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc277845","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Chyan, Oliver Ming-Ren","Acree, William E. (William Eugene)"]},{"key":"dc:creator","label":"Author","values":["Xu, Fei, 1971-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1997-05"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Semiconductors -- Design and construction.","Contamination (Technology)","metallic ion impurities","silicon-based sensing electrode"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved.","Xu, Fei, 1971-"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["call-no: 379 N81 no.7382","local-cont-no: 1002656548-xu","untcat: b2041269","https://digital.library.unt.edu/ark:/67531/metadc277845/","ark: ark:/67531/metadc277845"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Detection of ultratrace levels of metallic ion impurities in hydrofluoric acid solutions and alkaline hydrogen peroxide solution was demonstrated using a silicon-based sensing electrode. The sensor's operation principle is based on direct measurements of the silicon open-circuit potential shift generated by the interaction between metallic ions and the silicon-based sensing surface. The new sensor can have practical applications in the on-line monitoring of microelectronic chemical processing. The detection of Ag+ content in KODAK waste water was carried out successfully by this novel sensor. Trace levels of organic impurities in the hydrofluoric acid solutions and in the cleanroom air were characterized by multiple internal reflection infrared spectroscopy (MIRIS) using an organics probe prepared directly from a regular silicon wafer."]},{"key":"dc:format","label":"Dc Format","values":["xi, 129 leaves: ill.","Text"]},{"key":"dc:title","label":"Title","values":["Investigation of Ultratrace Metallic and Organic Contaminants in Semiconductor Processing Environments"]}]}],"canonical_facts":{"dc:contributor":["Chyan, Oliver Ming-Ren","Acree, William E. (William Eugene)"],"dc:creator":["Xu, Fei, 1971-"],"dc:date":["1997-05"],"dc:description":["Detection of ultratrace levels of metallic ion impurities in hydrofluoric acid solutions and alkaline hydrogen peroxide solution was demonstrated using a silicon-based sensing electrode. The sensor's operation principle is based on direct measurements of the silicon open-circuit potential shift generated by the interaction between metallic ions and the silicon-based sensing surface. The new sensor can have practical applications in the on-line monitoring of microelectronic chemical processing. The detection of Ag+ content in KODAK waste water was carried out successfully by this novel sensor. Trace levels of organic impurities in the hydrofluoric acid solutions and in the cleanroom air were characterized by multiple internal reflection infrared spectroscopy (MIRIS) using an organics probe prepared directly from a regular silicon wafer."],"dc:format":["xi, 129 leaves: ill.","Text"],"dc:identifier":["call-no: 379 N81 no.7382","local-cont-no: 1002656548-xu","untcat: b2041269","https://digital.library.unt.edu/ark:/67531/metadc277845/","ark: ark:/67531/metadc277845"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved.","Xu, Fei, 1971-"],"dc:subject":["Semiconductors -- Design and construction.","Contamination (Technology)","metallic ion impurities","silicon-based sensing electrode"],"dc:title":["Investigation of Ultratrace Metallic and Organic Contaminants in Semiconductor Processing Environments"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:50:51Z"}