{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc277875"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc277875","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Pretreatment Optimization of Fiberglass Manufacturing Industrial Wastewater","abstract":"Wastewater effluent produced in the fiberglass manufacturing industry contains a significant amount of total suspended solids. Environmental regulations require pretreatment of effluent before it is discharged to the municipal wastewater treatment plant. Chemical precipitation by coagulation and flocculation is the method of pretreatment used at the Vetrotex CertainTeed Corporation (VCT). A treatability study was conducted to determine conditions at which the VCT Wastewater Pretreatment Plant could operate to consistently achieve a total suspended solids concentration ≤ 200-mg/L. Jar tests varied pH, polymer dosage, and ferric sulfate dosage. Total suspended solids and turbidity were measured to evaluate treatment performance. The data were used to determine an optimum set of conditions under project guidelines. Of twelve polymers screened, BPL 594 was selected as the most effective polymer. For cost efficiency in the wastewater pretreatment operation, recommendations suggested that treatment chemical injection be electronically controlled according to turbidity of the treated effluent.","abstract_html":"Wastewater effluent produced in the fiberglass manufacturing industry contains a significant amount of total suspended solids. Environmental regulations require pretreatment of effluent before it is discharged to the municipal wastewater treatment plant. Chemical precipitation by coagulation and flocculation is the method of pretreatment used at the Vetrotex CertainTeed Corporation (VCT). A treatability study was conducted to determine conditions at which the VCT Wastewater Pretreatment Plant could operate to consistently achieve a total suspended solids concentration ≤ 200-mg/L. Jar tests varied pH, polymer dosage, and ferric sulfate dosage. Total suspended solids and turbidity were measured to evaluate treatment performance. The data were used to determine an optimum set of conditions under project guidelines. Of twelve polymers screened, BPL 594 was selected as the most effective polymer. For cost efficiency in the wastewater pretreatment operation, recommendations suggested that treatment chemical injection be electronically controlled according to turbidity of the treated effluent.","abstract_has_math":false,"creators":["Dragoo, Ron"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Atkinson, Samuel F.","Dickson, Kenneth L.","Hudak, Paul F."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1998,"date_issued":"1998-12","date_published":"1998-12","updated_at":"2026-11-19T08:50:51Z","subjects":["fiberglass","wastewater","manufacturing","environmental science","Water -- Purification.","Sanitary chemistry.","Glass fibers -- Environmental aspects."],"languages":["English"],"rights":["Public","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved.","Dragoo, Ron"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["call-no: 379 N81 no.7553","untcat: b2134071","local-cont-no: 1002660014-Dragoo","https://digital.library.unt.edu/ark:/67531/metadc277875/","ark: ark:/67531/metadc277875"],"render_values":[{"text":"call-no: 379 N81 no.7553","href":null,"code":true},{"text":"untcat: b2134071","href":null,"code":true},{"text":"local-cont-no: 1002660014-Dragoo","href":null,"code":true},{"text":"https://digital.library.unt.edu/ark:/67531/metadc277875/","href":"https://digital.library.unt.edu/ark:/67531/metadc277875/","code":true},{"text":"ark: ark:/67531/metadc277875","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.12794/metadc277875","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.12794/metadc277875","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc277875","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Atkinson, Samuel F.","Dickson, Kenneth L.","Hudak, Paul F."]},{"key":"dc:creator","label":"Author","values":["Dragoo, Ron"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:coverage","label":"Dc Coverage","values":["United States - Texas - Wichita County - Wichita Falls"]},{"key":"dc:date","label":"Dc Date","values":["1998-12"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["fiberglass","wastewater","manufacturing","environmental science","Water -- Purification.","Sanitary chemistry.","Glass fibers -- Environmental aspects."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved.","Dragoo, Ron"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["call-no: 379 N81 no.7553","doi: 10.12794/metadc277875","untcat: b2134071","local-cont-no: 1002660014-Dragoo","https://digital.library.unt.edu/ark:/67531/metadc277875/","ark: ark:/67531/metadc277875"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Wastewater effluent produced in the fiberglass manufacturing industry contains a significant amount of total suspended solids. Environmental regulations require pretreatment of effluent before it is discharged to the municipal wastewater treatment plant. Chemical precipitation by coagulation and flocculation is the method of pretreatment used at the Vetrotex CertainTeed Corporation (VCT). A treatability study was conducted to determine conditions at which the VCT Wastewater Pretreatment Plant could operate to consistently achieve a total suspended solids concentration ≤ 200-mg/L. Jar tests varied pH, polymer dosage, and ferric sulfate dosage. Total suspended solids and turbidity were measured to evaluate treatment performance. The data were used to determine an optimum set of conditions under project guidelines. Of twelve polymers screened, BPL 594 was selected as the most effective polymer. For cost efficiency in the wastewater pretreatment operation, recommendations suggested that treatment chemical injection be electronically controlled according to turbidity of the treated effluent."]},{"key":"dc:format","label":"Dc Format","values":["ix, 102 leaves : ill.","Text"]},{"key":"dc:title","label":"Title","values":["Pretreatment Optimization of Fiberglass Manufacturing Industrial Wastewater"]}]}],"canonical_facts":{"dc:contributor":["Atkinson, Samuel F.","Dickson, Kenneth L.","Hudak, Paul F."],"dc:coverage":["United States - Texas - Wichita County - Wichita Falls"],"dc:creator":["Dragoo, Ron"],"dc:date":["1998-12"],"dc:description":["Wastewater effluent produced in the fiberglass manufacturing industry contains a significant amount of total suspended solids. Environmental regulations require pretreatment of effluent before it is discharged to the municipal wastewater treatment plant. Chemical precipitation by coagulation and flocculation is the method of pretreatment used at the Vetrotex CertainTeed Corporation (VCT). A treatability study was conducted to determine conditions at which the VCT Wastewater Pretreatment Plant could operate to consistently achieve a total suspended solids concentration ≤ 200-mg/L. Jar tests varied pH, polymer dosage, and ferric sulfate dosage. Total suspended solids and turbidity were measured to evaluate treatment performance. The data were used to determine an optimum set of conditions under project guidelines. Of twelve polymers screened, BPL 594 was selected as the most effective polymer. For cost efficiency in the wastewater pretreatment operation, recommendations suggested that treatment chemical injection be electronically controlled according to turbidity of the treated effluent."],"dc:format":["ix, 102 leaves : ill.","Text"],"dc:identifier":["call-no: 379 N81 no.7553","doi: 10.12794/metadc277875","untcat: b2134071","local-cont-no: 1002660014-Dragoo","https://digital.library.unt.edu/ark:/67531/metadc277875/","ark: ark:/67531/metadc277875"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved.","Dragoo, Ron"],"dc:subject":["fiberglass","wastewater","manufacturing","environmental science","Water -- Purification.","Sanitary chemistry.","Glass fibers -- Environmental aspects."],"dc:title":["Pretreatment Optimization of Fiberglass Manufacturing Industrial Wastewater"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:50:51Z"}