{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc30444"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc30444","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Nominal Shear Strength and Seismic Detailing of Cold-formed Steel Shear Walls using Steel Sheet Sheathing","abstract":"In this research, monotonic and cyclic tests on cold-formed steel shear walls sheathed with steel sheets on one side were conducted to (1) verify the published nominal shear strength for 18-mil and 27-mil steel sheets; and (2) investigate the behavior of 6-ft. wide shear walls with multiple steel sheets. In objective 1: this research confirms the discrepancy existed in the published nominal strength of 27-mil sheets discovered by the previous project and verified the published nominal strength of 18 mil sheet for the wind design in AISI S213. The project also finds disagreement on the nominal strength of 18-mil sheets for seismic design, which is 29.0% higher than the published values. The research investigated 6-ft. wide shear wall with four framing and sheathing configurations. Configuration C, which used detailing, could provide the highest shear strength, compared to Configurations A and B. Meanwhile, the shear strength and stiffness of 2-ft. wide and 4-ft. wide wall can be improved by using the seismic detailing.","abstract_html":"In this research, monotonic and cyclic tests on cold-formed steel shear walls sheathed with steel sheets on one side were conducted to (1) verify the published nominal shear strength for 18-mil and 27-mil steel sheets; and (2) investigate the behavior of 6-ft. wide shear walls with multiple steel sheets. In objective 1: this research confirms the discrepancy existed in the published nominal strength of 27-mil sheets discovered by the previous project and verified the published nominal strength of 18 mil sheet for the wind design in AISI S213. The project also finds disagreement on the nominal strength of 18-mil sheets for seismic design, which is 29.0% higher than the published values. The research investigated 6-ft. wide shear wall with four framing and sheathing configurations. Configuration C, which used detailing, could provide the highest shear strength, compared to Configurations A and B. Meanwhile, the shear strength and stiffness of 2-ft. wide and 4-ft. wide wall can be improved by using the seismic detailing.","abstract_has_math":false,"creators":["Chen, Yujie"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Yu, Cheng","Nasrazadani, Seifollah","Arnold, Althea"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-08","date_published":"2010-08","updated_at":"2026-11-19T08:46:55Z","subjects":["shear wall","cold-formed steel","steel sheets","seismic design","Shear (Mechanics)","Shear walls.","Steel, Structural -- Testing.","Steel -- Cold working -- Testing.","Building, Iron and steel."],"languages":["English"],"rights":["Public","Copyright","Chen, Yujie","Copyright is held by the author, unless otherwise noted. All rights reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["oclc: 696395771","untcat: b3910418","https://digital.library.unt.edu/ark:/67531/metadc30444/","ark: ark:/67531/metadc30444"],"render_values":[{"text":"oclc: 696395771","href":null,"code":true},{"text":"untcat: b3910418","href":null,"code":true},{"text":"https://digital.library.unt.edu/ark:/67531/metadc30444/","href":"https://digital.library.unt.edu/ark:/67531/metadc30444/","code":true},{"text":"ark: ark:/67531/metadc30444","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.12794/metadc30444","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.12794/metadc30444","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc30444","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Yu, Cheng","Nasrazadani, Seifollah","Arnold, Althea"]},{"key":"dc:creator","label":"Author","values":["Chen, Yujie"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-08"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["shear wall","cold-formed steel","steel sheets","seismic design","Shear (Mechanics)","Shear walls.","Steel, Structural -- Testing.","Steel -- Cold working -- Testing.","Building, Iron and steel."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Copyright","Chen, Yujie","Copyright is held by the author, unless otherwise noted. All rights reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["oclc: 696395771","untcat: b3910418","doi: 10.12794/metadc30444","https://digital.library.unt.edu/ark:/67531/metadc30444/","ark: ark:/67531/metadc30444"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In this research, monotonic and cyclic tests on cold-formed steel shear walls sheathed with steel sheets on one side were conducted to (1) verify the published nominal shear strength for 18-mil and 27-mil steel sheets; and (2) investigate the behavior of 6-ft. wide shear walls with multiple steel sheets. In objective 1: this research confirms the discrepancy existed in the published nominal strength of 27-mil sheets discovered by the previous project and verified the published nominal strength of 18 mil sheet for the wind design in AISI S213. The project also finds disagreement on the nominal strength of 18-mil sheets for seismic design, which is 29.0% higher than the published values. The research investigated 6-ft. wide shear wall with four framing and sheathing configurations. Configuration C, which used detailing, could provide the highest shear strength, compared to Configurations A and B. Meanwhile, the shear strength and stiffness of 2-ft. wide and 4-ft. wide wall can be improved by using the seismic detailing."]},{"key":"dc:format","label":"Dc Format","values":["ix, 187 p. : ill.","Text"]},{"key":"dc:title","label":"Title","values":["Nominal Shear Strength and Seismic Detailing of Cold-formed Steel Shear Walls using Steel Sheet Sheathing"]}]}],"canonical_facts":{"dc:contributor":["Yu, Cheng","Nasrazadani, Seifollah","Arnold, Althea"],"dc:creator":["Chen, Yujie"],"dc:date":["2010-08"],"dc:description":["In this research, monotonic and cyclic tests on cold-formed steel shear walls sheathed with steel sheets on one side were conducted to (1) verify the published nominal shear strength for 18-mil and 27-mil steel sheets; and (2) investigate the behavior of 6-ft. wide shear walls with multiple steel sheets. In objective 1: this research confirms the discrepancy existed in the published nominal strength of 27-mil sheets discovered by the previous project and verified the published nominal strength of 18 mil sheet for the wind design in AISI S213. The project also finds disagreement on the nominal strength of 18-mil sheets for seismic design, which is 29.0% higher than the published values. The research investigated 6-ft. wide shear wall with four framing and sheathing configurations. Configuration C, which used detailing, could provide the highest shear strength, compared to Configurations A and B. Meanwhile, the shear strength and stiffness of 2-ft. wide and 4-ft. wide wall can be improved by using the seismic detailing."],"dc:format":["ix, 187 p. : ill.","Text"],"dc:identifier":["oclc: 696395771","untcat: b3910418","doi: 10.12794/metadc30444","https://digital.library.unt.edu/ark:/67531/metadc30444/","ark: ark:/67531/metadc30444"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Copyright","Chen, Yujie","Copyright is held by the author, unless otherwise noted. All rights reserved."],"dc:subject":["shear wall","cold-formed steel","steel sheets","seismic design","Shear (Mechanics)","Shear walls.","Steel, Structural -- Testing.","Steel -- Cold working -- Testing.","Building, Iron and steel."],"dc:title":["Nominal Shear Strength and Seismic Detailing of Cold-formed Steel Shear Walls using Steel Sheet Sheathing"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:46:55Z"}