{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc330927"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc330927","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Methods Development for Ion Chromatography","abstract":"Ion chromatography (IC) as developed by Small et. al. in 1975 has become an efficient and reliable analytical technique for simultaneous analysis of multiple ions in solution. The principle requirement prior to use the IC for an analysis is sample preparation; these include sample decomposition, solvent extraction, and trapping in case the target element is in the gas phase, etc. Solvent extractions for fluoride, chloride, sodium, ammonium, and potassium ions which are soluble in soils are described. Sample decompositions include silicate rocks using hydrofluoric acid for the determination of phosphorus; organic pesticides using lithium fusion technique for the determination of halide and cyanide ions are also described. After these sample preparation techniques, the aqueous solutions obtained were analyzed on the ion chromatograph for the analyses of the anions and cations mentioned above. Recovery and reproducibility of each technique is in general quite good and the comparison between the results obtained from the IC method and other instrumentation are given.","abstract_html":"Ion chromatography (IC) as developed by Small et. al. in 1975 has become an efficient and reliable analytical technique for simultaneous analysis of multiple ions in solution. The principle requirement prior to use the IC for an analysis is sample preparation; these include sample decomposition, solvent extraction, and trapping in case the target element is in the gas phase, etc. Solvent extractions for fluoride, chloride, sodium, ammonium, and potassium ions which are soluble in soils are described. Sample decompositions include silicate rocks using hydrofluoric acid for the determination of phosphorus; organic pesticides using lithium fusion technique for the determination of halide and cyanide ions are also described. After these sample preparation techniques, the aqueous solutions obtained were analyzed on the ion chromatograph for the analyses of the anions and cations mentioned above. Recovery and reproducibility of each technique is in general quite good and the comparison between the results obtained from the IC method and other instrumentation are given.","abstract_has_math":false,"creators":["Supachai Maketon"],"institution":"North Texas State University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Tarter, James G.","Daugherty, Kenneth E.","Harper, Keith J.","Schwartz, Martin","Thomas, Ruthanne D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1986,"date_issued":"1986-05","date_published":"1986-05","updated_at":"2026-11-19T08:52:31Z","subjects":["ion exchange","ion chromatography","Ion exchange chromatography"],"languages":["English"],"rights":["Public","Supachai Maketon","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: 1002715750-Maketon","call-no: 379 N81d no.2484","untcat: b1357228","oclc: 14784441","ark: ark:/67531/metadc330927"],"render_values":[{"text":"local-cont-no: 1002715750-Maketon","href":null,"code":true},{"text":"call-no: 379 N81d no.2484","href":null,"code":true},{"text":"untcat: b1357228","href":null,"code":true},{"text":"oclc: 14784441","href":null,"code":true},{"text":"ark: ark:/67531/metadc330927","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digital.library.unt.edu/ark:/67531/metadc330927/","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digital.library.unt.edu/ark:/67531/metadc330927/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc330927","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Tarter, James G.","Daugherty, Kenneth E.","Harper, Keith J.","Schwartz, Martin","Thomas, Ruthanne D."]},{"key":"dc:creator","label":"Author","values":["Supachai Maketon"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1986-05"]},{"key":"dc:publisher","label":"Institution","values":["North Texas State University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["ion exchange","ion chromatography","Ion exchange chromatography"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Supachai Maketon","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: 1002715750-Maketon","call-no: 379 N81d no.2484","untcat: b1357228","oclc: 14784441","https://digital.library.unt.edu/ark:/67531/metadc330927/","ark: ark:/67531/metadc330927"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Ion chromatography (IC) as developed by Small et. al. in 1975 has become an efficient and reliable analytical technique for simultaneous analysis of multiple ions in solution. The principle requirement prior to use the IC for an analysis is sample preparation; these include sample decomposition, solvent extraction, and trapping in case the target element is in the gas phase, etc. Solvent extractions for fluoride, chloride, sodium, ammonium, and potassium ions which are soluble in soils are described. Sample decompositions include silicate rocks using hydrofluoric acid for the determination of phosphorus; organic pesticides using lithium fusion technique for the determination of halide and cyanide ions are also described. After these sample preparation techniques, the aqueous solutions obtained were analyzed on the ion chromatograph for the analyses of the anions and cations mentioned above. Recovery and reproducibility of each technique is in general quite good and the comparison between the results obtained from the IC method and other instrumentation are given."]},{"key":"dc:format","label":"Dc Format","values":["iv, 81 leaves: ill.","Text"]},{"key":"dc:title","label":"Title","values":["Methods Development for Ion Chromatography"]}]}],"canonical_facts":{"dc:contributor":["Tarter, James G.","Daugherty, Kenneth E.","Harper, Keith J.","Schwartz, Martin","Thomas, Ruthanne D."],"dc:creator":["Supachai Maketon"],"dc:date":["1986-05"],"dc:description":["Ion chromatography (IC) as developed by Small et. al. in 1975 has become an efficient and reliable analytical technique for simultaneous analysis of multiple ions in solution. The principle requirement prior to use the IC for an analysis is sample preparation; these include sample decomposition, solvent extraction, and trapping in case the target element is in the gas phase, etc. Solvent extractions for fluoride, chloride, sodium, ammonium, and potassium ions which are soluble in soils are described. Sample decompositions include silicate rocks using hydrofluoric acid for the determination of phosphorus; organic pesticides using lithium fusion technique for the determination of halide and cyanide ions are also described. After these sample preparation techniques, the aqueous solutions obtained were analyzed on the ion chromatograph for the analyses of the anions and cations mentioned above. Recovery and reproducibility of each technique is in general quite good and the comparison between the results obtained from the IC method and other instrumentation are given."],"dc:format":["iv, 81 leaves: ill.","Text"],"dc:identifier":["local-cont-no: 1002715750-Maketon","call-no: 379 N81d no.2484","untcat: b1357228","oclc: 14784441","https://digital.library.unt.edu/ark:/67531/metadc330927/","ark: ark:/67531/metadc330927"],"dc:language":["English"],"dc:publisher":["North Texas State University"],"dc:rights":["Public","Supachai Maketon","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."],"dc:subject":["ion exchange","ion chromatography","Ion exchange chromatography"],"dc:title":["Methods Development for Ion Chromatography"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:52:31Z"}