{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc331468"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc331468","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Radial Compression High Performance Liquid Chromatography as a Tool for The Measurement of Endogenous Nucleotides in Bacteria","abstract":"High performance liquid chromatography was used to measure ribonucleoside triphosphates in microbial samples. Anion exchange columns in a radial compression module were used to separate and quantify purine and pyrimidine ribonucleotides. Endogenous ribonucleoside triphosphates were extracted from Escherichia coli and pseudomonas aeruginosa using three different solvents, namely trifluorocetic acid (TFA; 0.5M), trichloroacetic acid (TCA; 6 per cent w/v) and formic acid (1.0M) Extracts were assayed for uridine 5'-triphosphate (ATP), and guanosine 5'-triphosphate (GTP) by using anion exchange radial compression high performance (pressure) liquid chromatography. The three extraction produres were compared for yield of triphosphates. E. coli, the TFA extraction procedure was more sensitive and reliable than TCA and formic acid extraction procedures, but , in P. aeruginosa, the best yields of ATP and GTP were obrained following extraction with TFA. Yields of UTP and CTP increased when extraction was performed in TCA. These data illustrate that different extraction produres produce different measures for different triphosphates, a point often overlooked.","abstract_html":"High performance liquid chromatography was used to measure ribonucleoside triphosphates in microbial samples. Anion exchange columns in a radial compression module were used to separate and quantify purine and pyrimidine ribonucleotides. Endogenous ribonucleoside triphosphates were extracted from Escherichia coli and pseudomonas aeruginosa using three different solvents, namely trifluorocetic acid (TFA; 0.5M), trichloroacetic acid (TCA; 6 per cent w/v) and formic acid (1.0M) Extracts were assayed for uridine 5&#x27;-triphosphate (ATP), and guanosine 5&#x27;-triphosphate (GTP) by using anion exchange radial compression high performance (pressure) liquid chromatography. The three extraction produres were compared for yield of triphosphates. E. coli, the TFA extraction procedure was more sensitive and reliable than TCA and formic acid extraction procedures, but , in P. aeruginosa, the best yields of ATP and GTP were obrained following extraction with TFA. Yields of UTP and CTP increased when extraction was performed in TCA. These data illustrate that different extraction produres produce different measures for different triphosphates, a point often overlooked.","abstract_has_math":false,"creators":["Dutta, Probir Kumar"],"institution":"North Texas State University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["O'Donovan, Gerard A.","Zimmerman, Earl G.","Schafer, Rollie","Goven, Arthur James, 1950-","White, Olivia Masih"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1986,"date_issued":"1986-08","date_published":"1986-08","updated_at":"2026-11-19T08:51:39Z","subjects":["bacteria growth","endogenous nucleotides","liquid chromatography","Bacterial growth -- Measurement","Nucleotides","High performance liquid chromatography"],"languages":["English"],"rights":["Public","Dutta, Probir Kumar","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: 1002715727-Dutta","call-no: 379 N81d no.2520","untcat: b1370358","oclc: 15688516","ark: ark:/67531/metadc331468"],"render_values":[{"text":"local-cont-no: 1002715727-Dutta","href":null,"code":true},{"text":"call-no: 379 N81d no.2520","href":null,"code":true},{"text":"untcat: b1370358","href":null,"code":true},{"text":"oclc: 15688516","href":null,"code":true},{"text":"ark: ark:/67531/metadc331468","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digital.library.unt.edu/ark:/67531/metadc331468/","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digital.library.unt.edu/ark:/67531/metadc331468/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc331468","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["O'Donovan, Gerard A.","Zimmerman, Earl G.","Schafer, Rollie","Goven, Arthur James, 1950-","White, Olivia Masih"]},{"key":"dc:creator","label":"Author","values":["Dutta, Probir Kumar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1986-08"]},{"key":"dc:publisher","label":"Institution","values":["North Texas State University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["bacteria growth","endogenous nucleotides","liquid chromatography","Bacterial growth -- Measurement","Nucleotides","High performance liquid chromatography"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Dutta, Probir Kumar","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: 1002715727-Dutta","call-no: 379 N81d no.2520","untcat: b1370358","oclc: 15688516","https://digital.library.unt.edu/ark:/67531/metadc331468/","ark: ark:/67531/metadc331468"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["High performance liquid chromatography was used to measure ribonucleoside triphosphates in microbial samples. Anion exchange columns in a radial compression module were used to separate and quantify purine and pyrimidine ribonucleotides. Endogenous ribonucleoside triphosphates were extracted from Escherichia coli and pseudomonas aeruginosa using three different solvents, namely trifluorocetic acid (TFA; 0.5M), trichloroacetic acid (TCA; 6 per cent w/v) and formic acid (1.0M) Extracts were assayed for uridine 5'-triphosphate (ATP), and guanosine 5'-triphosphate (GTP) by using anion exchange radial compression high performance (pressure) liquid chromatography. The three extraction produres were compared for yield of triphosphates. E. coli, the TFA extraction procedure was more sensitive and reliable than TCA and formic acid extraction procedures, but , in P. aeruginosa, the best yields of ATP and GTP were obrained following extraction with TFA. Yields of UTP and CTP increased when extraction was performed in TCA. These data illustrate that different extraction produres produce different measures for different triphosphates, a point often overlooked."]},{"key":"dc:format","label":"Dc Format","values":["viii, 117 leaves: ill.","Text"]},{"key":"dc:title","label":"Title","values":["Radial Compression High Performance Liquid Chromatography as a Tool for The Measurement of Endogenous Nucleotides in Bacteria"]}]}],"canonical_facts":{"dc:contributor":["O'Donovan, Gerard A.","Zimmerman, Earl G.","Schafer, Rollie","Goven, Arthur James, 1950-","White, Olivia Masih"],"dc:creator":["Dutta, Probir Kumar"],"dc:date":["1986-08"],"dc:description":["High performance liquid chromatography was used to measure ribonucleoside triphosphates in microbial samples. Anion exchange columns in a radial compression module were used to separate and quantify purine and pyrimidine ribonucleotides. Endogenous ribonucleoside triphosphates were extracted from Escherichia coli and pseudomonas aeruginosa using three different solvents, namely trifluorocetic acid (TFA; 0.5M), trichloroacetic acid (TCA; 6 per cent w/v) and formic acid (1.0M) Extracts were assayed for uridine 5'-triphosphate (ATP), and guanosine 5'-triphosphate (GTP) by using anion exchange radial compression high performance (pressure) liquid chromatography. The three extraction produres were compared for yield of triphosphates. E. coli, the TFA extraction procedure was more sensitive and reliable than TCA and formic acid extraction procedures, but , in P. aeruginosa, the best yields of ATP and GTP were obrained following extraction with TFA. Yields of UTP and CTP increased when extraction was performed in TCA. These data illustrate that different extraction produres produce different measures for different triphosphates, a point often overlooked."],"dc:format":["viii, 117 leaves: ill.","Text"],"dc:identifier":["local-cont-no: 1002715727-Dutta","call-no: 379 N81d no.2520","untcat: b1370358","oclc: 15688516","https://digital.library.unt.edu/ark:/67531/metadc331468/","ark: ark:/67531/metadc331468"],"dc:language":["English"],"dc:publisher":["North Texas State University"],"dc:rights":["Public","Dutta, Probir Kumar","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."],"dc:subject":["bacteria growth","endogenous nucleotides","liquid chromatography","Bacterial growth -- Measurement","Nucleotides","High performance liquid chromatography"],"dc:title":["Radial Compression High Performance Liquid Chromatography as a Tool for The Measurement of Endogenous Nucleotides in Bacteria"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:51:39Z"}