{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc500392"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc500392","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Development and Validation of a Ramping Treadmill Protocol for the On-Line Measurement of Four Aerobic Parameters","abstract":"Previously, Whipp et. al. (J. Appl. Physiol.: Respirat. Environ. Exerc. Physiol. 50(1):217-221, 1981) demonstrated the feasibility of determining four parameters of aerobic function, identified as maximum oxygen uptake (μVO_2), VO_2 at anaerobic threshold (θan), the time constant for oxygen uptake kinetics (rVO_2) and work efficiency (η), using a short duration ramped bicycle ergometer exercise test. Because of the importance of being able to measure these parameters on a variety of measurement instruments a short duration ramping treadmill protocol has been developed. The ability of this protocol to determine the four aerobic parameters has been validated against conventional methods. The results of this investigation indicate that μVO_2, θan, rVO_2 and, η may be obtained from a single, short-duration ramping treadmill test.","abstract_html":"Previously, Whipp et. al. (J. Appl. Physiol.: Respirat. Environ. Exerc. Physiol. 50(1):217-221, 1981) demonstrated the feasibility of determining four parameters of aerobic function, identified as maximum oxygen uptake (μVO_2), VO_2 at anaerobic threshold (θan), the time constant for oxygen uptake kinetics (rVO_2) and work efficiency (η), using a short duration ramped bicycle ergometer exercise test. Because of the importance of being able to measure these parameters on a variety of measurement instruments a short duration ramping treadmill protocol has been developed. The ability of this protocol to determine the four aerobic parameters has been validated against conventional methods. The results of this investigation indicate that μVO_2, θan, rVO_2 and, η may be obtained from a single, short-duration ramping treadmill test.","abstract_has_math":false,"creators":["Cowell, Lynda L. (Lynda Lea)"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Raven, Peter Bernard, 1940-","Jones, Carl E.","Caffrey, James L.","Beitinger, Thomas L."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1990,"date_issued":"1990-05","date_published":"1990-05","updated_at":"2026-11-19T08:53:49Z","subjects":["aerobic function","aerobic parameters","ramping treadmill protocol","Treadmill exercise tests","Pulmonary function tests"],"languages":["English"],"rights":["Public","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved.","Cowell, Lynda L. (Lynda Lea)"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["call-no: 379 N81 no. 6606","local-cont-no: 1002779068-Cowell","untcat: b1451904","oclc: 23066750","ark: ark:/67531/metadc500392"],"render_values":[{"text":"call-no: 379 N81 no. 6606","href":null,"code":true},{"text":"local-cont-no: 1002779068-Cowell","href":null,"code":true},{"text":"untcat: b1451904","href":null,"code":true},{"text":"oclc: 23066750","href":null,"code":true},{"text":"ark: ark:/67531/metadc500392","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digital.library.unt.edu/ark:/67531/metadc500392/","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digital.library.unt.edu/ark:/67531/metadc500392/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc500392","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Raven, Peter Bernard, 1940-","Jones, Carl E.","Caffrey, James L.","Beitinger, Thomas L."]},{"key":"dc:creator","label":"Author","values":["Cowell, Lynda L. (Lynda Lea)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1990-05"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["aerobic function","aerobic parameters","ramping treadmill protocol","Treadmill exercise tests","Pulmonary function tests"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved.","Cowell, Lynda L. (Lynda Lea)"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["call-no: 379 N81 no. 6606","local-cont-no: 1002779068-Cowell","untcat: b1451904","oclc: 23066750","https://digital.library.unt.edu/ark:/67531/metadc500392/","ark: ark:/67531/metadc500392"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Previously, Whipp et. al. (J. Appl. Physiol.: Respirat. Environ. Exerc. Physiol. 50(1):217-221, 1981) demonstrated the feasibility of determining four parameters of aerobic function, identified as maximum oxygen uptake (μVO_2), VO_2 at anaerobic threshold (θan), the time constant for oxygen uptake kinetics (rVO_2) and work efficiency (η), using a short duration ramped bicycle ergometer exercise test. Because of the importance of being able to measure these parameters on a variety of measurement instruments a short duration ramping treadmill protocol has been developed. The ability of this protocol to determine the four aerobic parameters has been validated against conventional methods. The results of this investigation indicate that μVO_2, θan, rVO_2 and, η may be obtained from a single, short-duration ramping treadmill test."]},{"key":"dc:format","label":"Dc Format","values":["vii, 104 leaves : ill.","Text"]},{"key":"dc:title","label":"Title","values":["Development and Validation of a Ramping Treadmill Protocol for the On-Line Measurement of Four Aerobic Parameters"]}]}],"canonical_facts":{"dc:contributor":["Raven, Peter Bernard, 1940-","Jones, Carl E.","Caffrey, James L.","Beitinger, Thomas L."],"dc:creator":["Cowell, Lynda L. (Lynda Lea)"],"dc:date":["1990-05"],"dc:description":["Previously, Whipp et. al. (J. Appl. Physiol.: Respirat. Environ. Exerc. Physiol. 50(1):217-221, 1981) demonstrated the feasibility of determining four parameters of aerobic function, identified as maximum oxygen uptake (μVO_2), VO_2 at anaerobic threshold (θan), the time constant for oxygen uptake kinetics (rVO_2) and work efficiency (η), using a short duration ramped bicycle ergometer exercise test. Because of the importance of being able to measure these parameters on a variety of measurement instruments a short duration ramping treadmill protocol has been developed. The ability of this protocol to determine the four aerobic parameters has been validated against conventional methods. The results of this investigation indicate that μVO_2, θan, rVO_2 and, η may be obtained from a single, short-duration ramping treadmill test."],"dc:format":["vii, 104 leaves : ill.","Text"],"dc:identifier":["call-no: 379 N81 no. 6606","local-cont-no: 1002779068-Cowell","untcat: b1451904","oclc: 23066750","https://digital.library.unt.edu/ark:/67531/metadc500392/","ark: ark:/67531/metadc500392"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved.","Cowell, Lynda L. (Lynda Lea)"],"dc:subject":["aerobic function","aerobic parameters","ramping treadmill protocol","Treadmill exercise tests","Pulmonary function tests"],"dc:title":["Development and Validation of a Ramping Treadmill Protocol for the On-Line Measurement of Four Aerobic Parameters"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:53:49Z"}