{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc500410"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc500410","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Ion Chromatography of Soluble Cr(III) and Cr(VI)","abstract":"Ion chromatography coupled with a conductivity detector was used to investigate the analysis of Cr(III) and Cr(VI) in aqueous samples. An IC methodology for Cr(III) was developed using a cation column and an eluent containing tartaric acid, ethylenediamine, and acetonitrile at pH 2.9. The detection limit of this method can reach 0.1 ppm level with good precision. Several operational parameters were evaluated during the regular use of the method. Comparison of the IC method with AA method showed good agreement between the two methods. The anion exchange column was used for Cr(VI) determination. The best results were obtained with an eluent containing sodium gluconate, borate buffer, glycerin, and acetonitrile. The retention time for the Cr207 2 - sample was 11 min. and the calibration curve was linear between 1.0 and 100 ppm.","abstract_html":"Ion chromatography coupled with a conductivity detector was used to investigate the analysis of Cr(III) and Cr(VI) in aqueous samples. An IC methodology for Cr(III) was developed using a cation column and an eluent containing tartaric acid, ethylenediamine, and acetonitrile at pH 2.9. The detection limit of this method can reach 0.1 ppm level with good precision. Several operational parameters were evaluated during the regular use of the method. Comparison of the IC method with AA method showed good agreement between the two methods. The anion exchange column was used for Cr(VI) determination. The best results were obtained with an eluent containing sodium gluconate, borate buffer, glycerin, and acetonitrile. The retention time for the Cr207 2 - sample was 11 min. and the calibration curve was linear between 1.0 and 100 ppm.","abstract_has_math":false,"creators":["Huang, Julie Shiong-Jiun"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Saleh, Farida Y.","Tarter, James G.","Brady, William Thomas"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1988,"date_issued":"1988-08","date_published":"1988-08","updated_at":"2026-11-19T08:53:49Z","subjects":["ion chromatography","Chromium -- Analysis","Ion exchange chromatography","chromium","ion exchange"],"languages":["English"],"rights":["Public","Huang, Julie Shiong-Jiun","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["call-no: 379 N81 no.6457","untcat: b1443128","oclc: 20292951","local-cont-no: 1002775139-Huang","ark: ark:/67531/metadc500410"],"render_values":[{"text":"call-no: 379 N81 no.6457","href":null,"code":true},{"text":"untcat: b1443128","href":null,"code":true},{"text":"oclc: 20292951","href":null,"code":true},{"text":"local-cont-no: 1002775139-Huang","href":null,"code":true},{"text":"ark: ark:/67531/metadc500410","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digital.library.unt.edu/ark:/67531/metadc500410/","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digital.library.unt.edu/ark:/67531/metadc500410/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc500410","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Saleh, Farida Y.","Tarter, James G.","Brady, William Thomas"]},{"key":"dc:creator","label":"Author","values":["Huang, Julie Shiong-Jiun"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1988-08"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["ion chromatography","Chromium -- Analysis","Ion exchange chromatography","chromium","ion exchange"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Huang, Julie Shiong-Jiun","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["call-no: 379 N81 no.6457","untcat: b1443128","oclc: 20292951","local-cont-no: 1002775139-Huang","https://digital.library.unt.edu/ark:/67531/metadc500410/","ark: ark:/67531/metadc500410"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Ion chromatography coupled with a conductivity detector was used to investigate the analysis of Cr(III) and Cr(VI) in aqueous samples. An IC methodology for Cr(III) was developed using a cation column and an eluent containing tartaric acid, ethylenediamine, and acetonitrile at pH 2.9. The detection limit of this method can reach 0.1 ppm level with good precision. Several operational parameters were evaluated during the regular use of the method. Comparison of the IC method with AA method showed good agreement between the two methods. The anion exchange column was used for Cr(VI) determination. The best results were obtained with an eluent containing sodium gluconate, borate buffer, glycerin, and acetonitrile. The retention time for the Cr207 2 - sample was 11 min. and the calibration curve was linear between 1.0 and 100 ppm."]},{"key":"dc:format","label":"Dc Format","values":["viii, 75 leaves: ill.","Text"]},{"key":"dc:title","label":"Title","values":["Ion Chromatography of Soluble Cr(III) and Cr(VI)"]}]}],"canonical_facts":{"dc:contributor":["Saleh, Farida Y.","Tarter, James G.","Brady, William Thomas"],"dc:creator":["Huang, Julie Shiong-Jiun"],"dc:date":["1988-08"],"dc:description":["Ion chromatography coupled with a conductivity detector was used to investigate the analysis of Cr(III) and Cr(VI) in aqueous samples. An IC methodology for Cr(III) was developed using a cation column and an eluent containing tartaric acid, ethylenediamine, and acetonitrile at pH 2.9. The detection limit of this method can reach 0.1 ppm level with good precision. Several operational parameters were evaluated during the regular use of the method. Comparison of the IC method with AA method showed good agreement between the two methods. The anion exchange column was used for Cr(VI) determination. The best results were obtained with an eluent containing sodium gluconate, borate buffer, glycerin, and acetonitrile. The retention time for the Cr207 2 - sample was 11 min. and the calibration curve was linear between 1.0 and 100 ppm."],"dc:format":["viii, 75 leaves: ill.","Text"],"dc:identifier":["call-no: 379 N81 no.6457","untcat: b1443128","oclc: 20292951","local-cont-no: 1002775139-Huang","https://digital.library.unt.edu/ark:/67531/metadc500410/","ark: ark:/67531/metadc500410"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Huang, Julie Shiong-Jiun","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."],"dc:subject":["ion chromatography","Chromium -- Analysis","Ion exchange chromatography","chromium","ion exchange"],"dc:title":["Ion Chromatography of Soluble Cr(III) and Cr(VI)"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:53:49Z"}