{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc501145"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc501145","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Separation of Transition Metal Ions by HPLC, Using UV-VIS Detection","abstract":"HPLC has been used and can quickly determine several ions simultaneously. The method of determination described for transition metals [Cr(III), Fe(III), Ni(II), Co(II), Cu(II), Zn(II), Cd(II), Mn(II)] and [Ca(II), Pb(II)] using HPLC with UV-VIS detection is better than the PAR complexation method commonly used. The effects of both eluent pH and detector wavelength were investigated. Results from using different pHs and wavelengths, optional analytical conditions for the separation of [Ni(II), Co(II), Cu(II)], [Cr(III), Fe(III), Ca(II), Ni(II), Cu(II)], and [Ca(II), Zn(II), Pb(II)] in one injection, respectively, are described. The influence of adding different concentrations of Na_2EDTA solvent to the sample is shown. Detection limits, linear range, and the comparisons between this study and a post-column PAR method are given.","abstract_html":"HPLC has been used and can quickly determine several ions simultaneously. The method of determination described for transition metals [Cr(III), Fe(III), Ni(II), Co(II), Cu(II), Zn(II), Cd(II), Mn(II)] and [Ca(II), Pb(II)] using HPLC with UV-VIS detection is better than the PAR complexation method commonly used. The effects of both eluent pH and detector wavelength were investigated. Results from using different pHs and wavelengths, optional analytical conditions for the separation of [Ni(II), Co(II), Cu(II)], [Cr(III), Fe(III), Ca(II), Ni(II), Cu(II)], and [Ca(II), Zn(II), Pb(II)] in one injection, respectively, are described. The influence of adding different concentrations of Na_2EDTA solvent to the sample is shown. Detection limits, linear range, and the comparisons between this study and a post-column PAR method are given.","abstract_has_math":false,"creators":["Lien, Wan-Fu"],"institution":"North Texas State University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Tarter, James G.","Daugherty, Kenneth E.","Saleh, Farida Y."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1987,"date_issued":"1987-08","date_published":"1987-08","updated_at":"2026-11-19T08:53:49Z","subjects":["high performance liquid chromatography","untraviolet-visible detection systems","ion separation","Separation (Technology)","Metal ions -- Spectra","Transition metals -- Spectra","Ultraviolet spectrometry"],"languages":["English"],"rights":["Public","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved.","Lien, Wan-Fu"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["call-no: 379 N81 no. 6369","local-cont-no: 1002775228-Lien","untcat: b1405902","oclc: 18077033","ark: ark:/67531/metadc501145"],"render_values":[{"text":"call-no: 379 N81 no. 6369","href":null,"code":true},{"text":"local-cont-no: 1002775228-Lien","href":null,"code":true},{"text":"untcat: b1405902","href":null,"code":true},{"text":"oclc: 18077033","href":null,"code":true},{"text":"ark: ark:/67531/metadc501145","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digital.library.unt.edu/ark:/67531/metadc501145/","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digital.library.unt.edu/ark:/67531/metadc501145/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc501145","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Tarter, James G.","Daugherty, Kenneth E.","Saleh, Farida Y."]},{"key":"dc:creator","label":"Author","values":["Lien, Wan-Fu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1987-08"]},{"key":"dc:publisher","label":"Institution","values":["North Texas State University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["high performance liquid chromatography","untraviolet-visible detection systems","ion separation","Separation (Technology)","Metal ions -- Spectra","Transition metals -- Spectra","Ultraviolet spectrometry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved.","Lien, Wan-Fu"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["call-no: 379 N81 no. 6369","local-cont-no: 1002775228-Lien","untcat: b1405902","oclc: 18077033","https://digital.library.unt.edu/ark:/67531/metadc501145/","ark: ark:/67531/metadc501145"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["HPLC has been used and can quickly determine several ions simultaneously. The method of determination described for transition metals [Cr(III), Fe(III), Ni(II), Co(II), Cu(II), Zn(II), Cd(II), Mn(II)] and [Ca(II), Pb(II)] using HPLC with UV-VIS detection is better than the PAR complexation method commonly used. The effects of both eluent pH and detector wavelength were investigated. Results from using different pHs and wavelengths, optional analytical conditions for the separation of [Ni(II), Co(II), Cu(II)], [Cr(III), Fe(III), Ca(II), Ni(II), Cu(II)], and [Ca(II), Zn(II), Pb(II)] in one injection, respectively, are described. The influence of adding different concentrations of Na_2EDTA solvent to the sample is shown. Detection limits, linear range, and the comparisons between this study and a post-column PAR method are given."]},{"key":"dc:format","label":"Dc Format","values":["vii, 47 leaves : ill.","Text"]},{"key":"dc:title","label":"Title","values":["Separation of Transition Metal Ions by HPLC, Using UV-VIS Detection"]}]}],"canonical_facts":{"dc:contributor":["Tarter, James G.","Daugherty, Kenneth E.","Saleh, Farida Y."],"dc:creator":["Lien, Wan-Fu"],"dc:date":["1987-08"],"dc:description":["HPLC has been used and can quickly determine several ions simultaneously. The method of determination described for transition metals [Cr(III), Fe(III), Ni(II), Co(II), Cu(II), Zn(II), Cd(II), Mn(II)] and [Ca(II), Pb(II)] using HPLC with UV-VIS detection is better than the PAR complexation method commonly used. The effects of both eluent pH and detector wavelength were investigated. Results from using different pHs and wavelengths, optional analytical conditions for the separation of [Ni(II), Co(II), Cu(II)], [Cr(III), Fe(III), Ca(II), Ni(II), Cu(II)], and [Ca(II), Zn(II), Pb(II)] in one injection, respectively, are described. The influence of adding different concentrations of Na_2EDTA solvent to the sample is shown. Detection limits, linear range, and the comparisons between this study and a post-column PAR method are given."],"dc:format":["vii, 47 leaves : ill.","Text"],"dc:identifier":["call-no: 379 N81 no. 6369","local-cont-no: 1002775228-Lien","untcat: b1405902","oclc: 18077033","https://digital.library.unt.edu/ark:/67531/metadc501145/","ark: ark:/67531/metadc501145"],"dc:language":["English"],"dc:publisher":["North Texas State University"],"dc:rights":["Public","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved.","Lien, Wan-Fu"],"dc:subject":["high performance liquid chromatography","untraviolet-visible detection systems","ion separation","Separation (Technology)","Metal ions -- Spectra","Transition metals -- Spectra","Ultraviolet spectrometry"],"dc:title":["Separation of Transition Metal Ions by HPLC, Using UV-VIS Detection"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:53:49Z"}