{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc503866"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc503866","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"A Model for Determining Induced Physiological Stress During Respirator Wear","abstract":"A model was developed to predict the increased physiological effort of wearing a respiratory protective device. Specifically, the model was designed to predict the effects of varying ventilatory demands on eleven respiratory variables of the man-respirator system, breath frequency (f_b), tidal volume (V_t), inspiratory flow (dvi/dt), expiratory flow (dve/dt), inspiratory mask pressure (P_mi), expiratory mask pressure (P_me), inspiratory intrathoracic pressure (P_ii), expiratory intrathoracic pressure (P_ie), inspiratory mask work (W_mi), expiratory mask work (W_me), and mask leakage index (L_i). The model was tested by experiment in which three male subjects underwent maximal exercise testing with and without the \"pressure-demand\" respirator. The eleven variables were determined for each thirty second period utilizing on-line computer analysis. Application of the model to these experimental conditions resulted in significant (p<.001) relationships between each of the predicted and observed variables.","abstract_html":"A model was developed to predict the increased physiological effort of wearing a respiratory protective device. Specifically, the model was designed to predict the effects of varying ventilatory demands on eleven respiratory variables of the man-respirator system, breath frequency (f_b), tidal volume (V_t), inspiratory flow (dvi/dt), expiratory flow (dve/dt), inspiratory mask pressure (P_mi), expiratory mask pressure (P_me), inspiratory intrathoracic pressure (P_ii), expiratory intrathoracic pressure (P_ie), inspiratory mask work (W_mi), expiratory mask work (W_me), and mask leakage index (L_i). The model was tested by experiment in which three male subjects underwent maximal exercise testing with and without the &quot;pressure-demand&quot; respirator. The eleven variables were determined for each thirty second period utilizing on-line computer analysis. Application of the model to these experimental conditions resulted in significant (p&lt;.001) relationships between each of the predicted and observed variables.","abstract_has_math":false,"creators":["Meyer, Steve D. (Steve Douglas)"],"institution":"North Texas State University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Raven, Peter Bernard, 1940-","Jones, Carl E.","Gaugl, John F."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1984,"date_issued":"1984-12","date_published":"1984-12","updated_at":"2026-11-19T08:54:00Z","subjects":["respirator use","physiological stress","Breathing apparatus -- Physiological effect -- Mathematical models"],"languages":["English"],"rights":["Public","Meyer, Steve D. (Steve Douglas)","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: 1002775555-Meyer","call-no: 379 N81 no. 6126","untcat: b1868800","oclc: 12213544","ark: ark:/67531/metadc503866"],"render_values":[{"text":"local-cont-no: 1002775555-Meyer","href":null,"code":true},{"text":"call-no: 379 N81 no. 6126","href":null,"code":true},{"text":"untcat: b1868800","href":null,"code":true},{"text":"oclc: 12213544","href":null,"code":true},{"text":"ark: ark:/67531/metadc503866","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digital.library.unt.edu/ark:/67531/metadc503866/","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digital.library.unt.edu/ark:/67531/metadc503866/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc503866","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Raven, Peter Bernard, 1940-","Jones, Carl E.","Gaugl, John F."]},{"key":"dc:creator","label":"Author","values":["Meyer, Steve D. (Steve Douglas)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1984-12"]},{"key":"dc:publisher","label":"Institution","values":["North Texas State University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["respirator use","physiological stress","Breathing apparatus -- Physiological effect -- Mathematical models"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Meyer, Steve D. (Steve Douglas)","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: 1002775555-Meyer","call-no: 379 N81 no. 6126","untcat: b1868800","oclc: 12213544","https://digital.library.unt.edu/ark:/67531/metadc503866/","ark: ark:/67531/metadc503866"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A model was developed to predict the increased physiological effort of wearing a respiratory protective device. Specifically, the model was designed to predict the effects of varying ventilatory demands on eleven respiratory variables of the man-respirator system, breath frequency (f_b), tidal volume (V_t), inspiratory flow (dvi/dt), expiratory flow (dve/dt), inspiratory mask pressure (P_mi), expiratory mask pressure (P_me), inspiratory intrathoracic pressure (P_ii), expiratory intrathoracic pressure (P_ie), inspiratory mask work (W_mi), expiratory mask work (W_me), and mask leakage index (L_i). The model was tested by experiment in which three male subjects underwent maximal exercise testing with and without the \"pressure-demand\" respirator. The eleven variables were determined for each thirty second period utilizing on-line computer analysis. Application of the model to these experimental conditions resulted in significant (p<.001) relationships between each of the predicted and observed variables."]},{"key":"dc:format","label":"Dc Format","values":["v, 81 leaves : ill.","Text"]},{"key":"dc:title","label":"Title","values":["A Model for Determining Induced Physiological Stress During Respirator Wear"]}]}],"canonical_facts":{"dc:contributor":["Raven, Peter Bernard, 1940-","Jones, Carl E.","Gaugl, John F."],"dc:creator":["Meyer, Steve D. (Steve Douglas)"],"dc:date":["1984-12"],"dc:description":["A model was developed to predict the increased physiological effort of wearing a respiratory protective device. Specifically, the model was designed to predict the effects of varying ventilatory demands on eleven respiratory variables of the man-respirator system, breath frequency (f_b), tidal volume (V_t), inspiratory flow (dvi/dt), expiratory flow (dve/dt), inspiratory mask pressure (P_mi), expiratory mask pressure (P_me), inspiratory intrathoracic pressure (P_ii), expiratory intrathoracic pressure (P_ie), inspiratory mask work (W_mi), expiratory mask work (W_me), and mask leakage index (L_i). The model was tested by experiment in which three male subjects underwent maximal exercise testing with and without the \"pressure-demand\" respirator. The eleven variables were determined for each thirty second period utilizing on-line computer analysis. Application of the model to these experimental conditions resulted in significant (p<.001) relationships between each of the predicted and observed variables."],"dc:format":["v, 81 leaves : ill.","Text"],"dc:identifier":["local-cont-no: 1002775555-Meyer","call-no: 379 N81 no. 6126","untcat: b1868800","oclc: 12213544","https://digital.library.unt.edu/ark:/67531/metadc503866/","ark: ark:/67531/metadc503866"],"dc:language":["English"],"dc:publisher":["North Texas State University"],"dc:rights":["Public","Meyer, Steve D. (Steve Douglas)","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."],"dc:subject":["respirator use","physiological stress","Breathing apparatus -- Physiological effect -- Mathematical models"],"dc:title":["A Model for Determining Induced Physiological Stress During Respirator Wear"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:54:00Z"}