{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc504486"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc504486","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"The Determination of Organic-Bound Chlorine Levels in Municipal Wastewaters After Treatment with Heavy Chlorine Doses","abstract":"The development of an analytical method for the determination of total organic-bound chlorine (TOCl) produced during the chlorination of municipal wastewater effluents is presented. Sewage effluent from the Denton, Texas municipal treatment plant was chlorinated at high chlorine doses (1000 - 4000 ppm), as well as typical treatment levels. Chlororganics present in the wastewater, before and after chlorination, were concentrated by adsorption on Amberlite XAD-2 macroreticular resin, followed by elution with diethyl ether. After concentration, the extracts were analyzed for TOC1 by microcoulometry. Analysis of wastewater extracts revealed the production of substantial amounts of new chlorinated organics when effluents were treated with chlorine. The method shows good precision and estimated accuracy is favorable.","abstract_html":"The development of an analytical method for the determination of total organic-bound chlorine (TOCl) produced during the chlorination of municipal wastewater effluents is presented. Sewage effluent from the Denton, Texas municipal treatment plant was chlorinated at high chlorine doses (1000 - 4000 ppm), as well as typical treatment levels. Chlororganics present in the wastewater, before and after chlorination, were concentrated by adsorption on Amberlite XAD-2 macroreticular resin, followed by elution with diethyl ether. After concentration, the extracts were analyzed for TOC1 by microcoulometry. Analysis of wastewater extracts revealed the production of substantial amounts of new chlorinated organics when effluents were treated with chlorine. The method shows good precision and estimated accuracy is favorable.","abstract_has_math":false,"creators":["Smith, Garmon B."],"institution":"North Texas State University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Glaze, William","Jacobson, Myron","Stanford, Jack Arthur, 1947-"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1976,"date_issued":"1976-05","date_published":"1976-05","updated_at":"2026-11-19T08:54:00Z","subjects":["organic-bound chlorine levels","municipal wastewater effluents","chlorine treatments","chlorine buildup","Chlorination.","Sewage -- Purification -- Chlorination.","Organochlorine compounds."],"languages":["English"],"rights":["Public","Smith, Garmon B.","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: 1002773205-Smith","call-no: 379 N81 no.5177","untcat: b1151029","oclc: 2438130","ark: ark:/67531/metadc504486"],"render_values":[{"text":"local-cont-no: 1002773205-Smith","href":null,"code":true},{"text":"call-no: 379 N81 no.5177","href":null,"code":true},{"text":"untcat: b1151029","href":null,"code":true},{"text":"oclc: 2438130","href":null,"code":true},{"text":"ark: ark:/67531/metadc504486","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digital.library.unt.edu/ark:/67531/metadc504486/","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digital.library.unt.edu/ark:/67531/metadc504486/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc504486","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Glaze, William","Jacobson, Myron","Stanford, Jack Arthur, 1947-"]},{"key":"dc:creator","label":"Author","values":["Smith, Garmon B."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1976-05"]},{"key":"dc:publisher","label":"Institution","values":["North Texas State University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["organic-bound chlorine levels","municipal wastewater effluents","chlorine treatments","chlorine buildup","Chlorination.","Sewage -- Purification -- Chlorination.","Organochlorine compounds."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Smith, Garmon B.","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: 1002773205-Smith","call-no: 379 N81 no.5177","untcat: b1151029","oclc: 2438130","https://digital.library.unt.edu/ark:/67531/metadc504486/","ark: ark:/67531/metadc504486"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The development of an analytical method for the determination of total organic-bound chlorine (TOCl) produced during the chlorination of municipal wastewater effluents is presented. Sewage effluent from the Denton, Texas municipal treatment plant was chlorinated at high chlorine doses (1000 - 4000 ppm), as well as typical treatment levels. Chlororganics present in the wastewater, before and after chlorination, were concentrated by adsorption on Amberlite XAD-2 macroreticular resin, followed by elution with diethyl ether. After concentration, the extracts were analyzed for TOC1 by microcoulometry. Analysis of wastewater extracts revealed the production of substantial amounts of new chlorinated organics when effluents were treated with chlorine. The method shows good precision and estimated accuracy is favorable."]},{"key":"dc:format","label":"Dc Format","values":["v, 93 leaves : ill.","Text"]},{"key":"dc:title","label":"Title","values":["The Determination of Organic-Bound Chlorine Levels in Municipal Wastewaters After Treatment with Heavy Chlorine Doses"]}]}],"canonical_facts":{"dc:contributor":["Glaze, William","Jacobson, Myron","Stanford, Jack Arthur, 1947-"],"dc:creator":["Smith, Garmon B."],"dc:date":["1976-05"],"dc:description":["The development of an analytical method for the determination of total organic-bound chlorine (TOCl) produced during the chlorination of municipal wastewater effluents is presented. Sewage effluent from the Denton, Texas municipal treatment plant was chlorinated at high chlorine doses (1000 - 4000 ppm), as well as typical treatment levels. Chlororganics present in the wastewater, before and after chlorination, were concentrated by adsorption on Amberlite XAD-2 macroreticular resin, followed by elution with diethyl ether. After concentration, the extracts were analyzed for TOC1 by microcoulometry. Analysis of wastewater extracts revealed the production of substantial amounts of new chlorinated organics when effluents were treated with chlorine. The method shows good precision and estimated accuracy is favorable."],"dc:format":["v, 93 leaves : ill.","Text"],"dc:identifier":["local-cont-no: 1002773205-Smith","call-no: 379 N81 no.5177","untcat: b1151029","oclc: 2438130","https://digital.library.unt.edu/ark:/67531/metadc504486/","ark: ark:/67531/metadc504486"],"dc:language":["English"],"dc:publisher":["North Texas State University"],"dc:rights":["Public","Smith, Garmon B.","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."],"dc:subject":["organic-bound chlorine levels","municipal wastewater effluents","chlorine treatments","chlorine buildup","Chlorination.","Sewage -- Purification -- Chlorination.","Organochlorine compounds."],"dc:title":["The Determination of Organic-Bound Chlorine Levels in Municipal Wastewaters After Treatment with Heavy Chlorine Doses"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:54:00Z"}