{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc6072"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc6072","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Flow Accelerated Corrosion Experience at Comanche Peak Steam Electric Station","abstract":"Flow accelerated corrosion (FAC) is a major concern in the power industry as it causes thinning of the pipes by the dissolution of the passive oxide layer formed on the pipe surface. Present research deals with comparing the protection offered by the magnetite (Fe3O4) versus maghemite (γ-Fe2O3) phases thickness loss measurements. Fourier transform infrared spectroscopy (FTIR) is used in distinguishing these two elusive phases of iron oxides. Representative pipes are collected from high pressure steam extraction line of the secondary cycle of unit 2 of Comanche Peak Steam Electric Station (CPSES). Environmental scanning electron microscopy (ESEM) is used for morphological analysis. FTIR and X-ray diffraction (XRD) are used for phase analysis. Morphological analysis showed the presence of porous oxide surfaces with octahedral crystals, scallops and \"chimney\" like vents. FTIR revealed the predominance of maghemite at the most of the pipe sections. Results of thickness measurements indicate severe thickness loss at the bend areas (extrados) of the pipes.","abstract_html":"Flow accelerated corrosion (FAC) is a major concern in the power industry as it causes thinning of the pipes by the dissolution of the passive oxide layer formed on the pipe surface. Present research deals with comparing the protection offered by the magnetite (Fe3O4) versus maghemite (γ-Fe2O3) phases thickness loss measurements. Fourier transform infrared spectroscopy (FTIR) is used in distinguishing these two elusive phases of iron oxides. Representative pipes are collected from high pressure steam extraction line of the secondary cycle of unit 2 of Comanche Peak Steam Electric Station (CPSES). Environmental scanning electron microscopy (ESEM) is used for morphological analysis. FTIR and X-ray diffraction (XRD) are used for phase analysis. Morphological analysis showed the presence of porous oxide surfaces with octahedral crystals, scallops and &quot;chimney&quot; like vents. FTIR revealed the predominance of maghemite at the most of the pipe sections. Results of thickness measurements indicate severe thickness loss at the bend areas (extrados) of the pipes.","abstract_has_math":false,"creators":["Nakka, Ravi Kumar"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Nasrazadani, Seifollah","Plummer, Mitty C.","Foster, Phillip R."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-05","date_published":"2008-05","updated_at":"2026-11-19T08:45:59Z","subjects":["FAC","maghemite","magnetite","iron oxides","FTIR","XRD","ESEM","Comanche Peak Steam Electric Station (Tex.)","Water-pipes -- Corrosion.","Iron oxides.","Steam-boilers -- Corrosion.","Pressurized water reactors."],"languages":["English"],"rights":["Public","Copyright","Nakka, Ravi Kumar","Copyright is held by the author, unless otherwise noted. All rights reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["oclc: 262285417","https://digital.library.unt.edu/ark:/67531/metadc6072/","ark: ark:/67531/metadc6072"],"render_values":[{"text":"oclc: 262285417","href":null,"code":true},{"text":"https://digital.library.unt.edu/ark:/67531/metadc6072/","href":"https://digital.library.unt.edu/ark:/67531/metadc6072/","code":true},{"text":"ark: ark:/67531/metadc6072","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.12794/metadc6072","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.12794/metadc6072","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc6072","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Nasrazadani, Seifollah","Plummer, Mitty C.","Foster, Phillip R."]},{"key":"dc:creator","label":"Author","values":["Nakka, Ravi Kumar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-05"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["FAC","maghemite","magnetite","iron oxides","FTIR","XRD","ESEM","Comanche Peak Steam Electric Station (Tex.)","Water-pipes -- Corrosion.","Iron oxides.","Steam-boilers -- Corrosion.","Pressurized water reactors."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Copyright","Nakka, Ravi Kumar","Copyright is held by the author, unless otherwise noted. All rights reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["oclc: 262285417","doi: 10.12794/metadc6072","https://digital.library.unt.edu/ark:/67531/metadc6072/","ark: ark:/67531/metadc6072"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Flow accelerated corrosion (FAC) is a major concern in the power industry as it causes thinning of the pipes by the dissolution of the passive oxide layer formed on the pipe surface. Present research deals with comparing the protection offered by the magnetite (Fe3O4) versus maghemite (γ-Fe2O3) phases thickness loss measurements. Fourier transform infrared spectroscopy (FTIR) is used in distinguishing these two elusive phases of iron oxides. Representative pipes are collected from high pressure steam extraction line of the secondary cycle of unit 2 of Comanche Peak Steam Electric Station (CPSES). Environmental scanning electron microscopy (ESEM) is used for morphological analysis. FTIR and X-ray diffraction (XRD) are used for phase analysis. Morphological analysis showed the presence of porous oxide surfaces with octahedral crystals, scallops and \"chimney\" like vents. FTIR revealed the predominance of maghemite at the most of the pipe sections. Results of thickness measurements indicate severe thickness loss at the bend areas (extrados) of the pipes."]},{"key":"dc:format","label":"Dc Format","values":["Text"]},{"key":"dc:title","label":"Title","values":["Flow Accelerated Corrosion Experience at Comanche Peak Steam Electric Station"]}]}],"canonical_facts":{"dc:contributor":["Nasrazadani, Seifollah","Plummer, Mitty C.","Foster, Phillip R."],"dc:creator":["Nakka, Ravi Kumar"],"dc:date":["2008-05"],"dc:description":["Flow accelerated corrosion (FAC) is a major concern in the power industry as it causes thinning of the pipes by the dissolution of the passive oxide layer formed on the pipe surface. Present research deals with comparing the protection offered by the magnetite (Fe3O4) versus maghemite (γ-Fe2O3) phases thickness loss measurements. Fourier transform infrared spectroscopy (FTIR) is used in distinguishing these two elusive phases of iron oxides. Representative pipes are collected from high pressure steam extraction line of the secondary cycle of unit 2 of Comanche Peak Steam Electric Station (CPSES). Environmental scanning electron microscopy (ESEM) is used for morphological analysis. FTIR and X-ray diffraction (XRD) are used for phase analysis. Morphological analysis showed the presence of porous oxide surfaces with octahedral crystals, scallops and \"chimney\" like vents. FTIR revealed the predominance of maghemite at the most of the pipe sections. Results of thickness measurements indicate severe thickness loss at the bend areas (extrados) of the pipes."],"dc:format":["Text"],"dc:identifier":["oclc: 262285417","doi: 10.12794/metadc6072","https://digital.library.unt.edu/ark:/67531/metadc6072/","ark: ark:/67531/metadc6072"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Copyright","Nakka, Ravi Kumar","Copyright is held by the author, unless otherwise noted. All rights reserved."],"dc:subject":["FAC","maghemite","magnetite","iron oxides","FTIR","XRD","ESEM","Comanche Peak Steam Electric Station (Tex.)","Water-pipes -- Corrosion.","Iron oxides.","Steam-boilers -- Corrosion.","Pressurized water reactors."],"dc:title":["Flow Accelerated Corrosion Experience at Comanche Peak Steam Electric Station"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:45:59Z"}