{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc67963"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc67963","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Mechanisms Affecting Bench Press Throw Performance while Using a Counter-Balanced Smith Machine","abstract":"The use of a counter-balance weight system of a Smith machine affects measures of bench press throw performance. Twenty-four men performed bench press throws at 30% of their one-repetition maximum under four different conditions: 1) counter-balance and rebound movement (RC), 2) no counter-balance and rebound movement (RNC), 3) counter-balance and concentric only movement (CC), and 4) no counter-balance and concentric only movement (CNC). Peak power, force, and concentric and eccentric velocities were measured using a linear accelerometer; and peak ground reaction force (GRF) was measured using a forceplate. Peak measures for concentric and eccentric velocities showed that NCB> CB and RBT > CBT. Peak GRF measures showed CB > NCB and RBT > CBT. The lower performance measures for CB were likely due to an increase in the net external load when the barbell accelerates faster than the gravitational constant causing the counter-balance weight becomes ineffective.","abstract_html":"The use of a counter-balance weight system of a Smith machine affects measures of bench press throw performance. Twenty-four men performed bench press throws at 30% of their one-repetition maximum under four different conditions: 1) counter-balance and rebound movement (RC), 2) no counter-balance and rebound movement (RNC), 3) counter-balance and concentric only movement (CC), and 4) no counter-balance and concentric only movement (CNC). Peak power, force, and concentric and eccentric velocities were measured using a linear accelerometer; and peak ground reaction force (GRF) was measured using a forceplate. Peak measures for concentric and eccentric velocities showed that NCB&gt; CB and RBT &gt; CBT. Peak GRF measures showed CB &gt; NCB and RBT &gt; CBT. The lower performance measures for CB were likely due to an increase in the net external load when the barbell accelerates faster than the gravitational constant causing the counter-balance weight becomes ineffective.","abstract_has_math":false,"creators":["Buddhadev, Harsh"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Vingren, Jakob L.","Hill, David W.","Driver, Simon","Goggin, Noreen L."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-05","date_published":"2011-05","updated_at":"2026-11-19T08:46:55Z","subjects":["bench press throw","counter-balanced","linear accelerometer","peak power","Smith machine"],"languages":["English"],"rights":["Public","Copyright","Buddhadev, Harsh","Copyright is held by the author, unless otherwise noted. All rights reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digital.library.unt.edu/ark:/67531/metadc67963/","ark: ark:/67531/metadc67963"],"render_values":[{"text":"https://digital.library.unt.edu/ark:/67531/metadc67963/","href":"https://digital.library.unt.edu/ark:/67531/metadc67963/","code":true},{"text":"ark: ark:/67531/metadc67963","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.12794/metadc67963","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.12794/metadc67963","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc67963","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Vingren, Jakob L.","Hill, David W.","Driver, Simon","Goggin, Noreen L."]},{"key":"dc:creator","label":"Author","values":["Buddhadev, Harsh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-05"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["bench press throw","counter-balanced","linear accelerometer","peak power","Smith machine"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Copyright","Buddhadev, Harsh","Copyright is held by the author, unless otherwise noted. All rights reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["doi: 10.12794/metadc67963","https://digital.library.unt.edu/ark:/67531/metadc67963/","ark: ark:/67531/metadc67963"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The use of a counter-balance weight system of a Smith machine affects measures of bench press throw performance. Twenty-four men performed bench press throws at 30% of their one-repetition maximum under four different conditions: 1) counter-balance and rebound movement (RC), 2) no counter-balance and rebound movement (RNC), 3) counter-balance and concentric only movement (CC), and 4) no counter-balance and concentric only movement (CNC). Peak power, force, and concentric and eccentric velocities were measured using a linear accelerometer; and peak ground reaction force (GRF) was measured using a forceplate. Peak measures for concentric and eccentric velocities showed that NCB> CB and RBT > CBT. Peak GRF measures showed CB > NCB and RBT > CBT. The lower performance measures for CB were likely due to an increase in the net external load when the barbell accelerates faster than the gravitational constant causing the counter-balance weight becomes ineffective."]},{"key":"dc:format","label":"Dc Format","values":["Text"]},{"key":"dc:title","label":"Title","values":["Mechanisms Affecting Bench Press Throw Performance while Using a Counter-Balanced Smith Machine"]}]}],"canonical_facts":{"dc:contributor":["Vingren, Jakob L.","Hill, David W.","Driver, Simon","Goggin, Noreen L."],"dc:creator":["Buddhadev, Harsh"],"dc:date":["2011-05"],"dc:description":["The use of a counter-balance weight system of a Smith machine affects measures of bench press throw performance. Twenty-four men performed bench press throws at 30% of their one-repetition maximum under four different conditions: 1) counter-balance and rebound movement (RC), 2) no counter-balance and rebound movement (RNC), 3) counter-balance and concentric only movement (CC), and 4) no counter-balance and concentric only movement (CNC). Peak power, force, and concentric and eccentric velocities were measured using a linear accelerometer; and peak ground reaction force (GRF) was measured using a forceplate. Peak measures for concentric and eccentric velocities showed that NCB> CB and RBT > CBT. Peak GRF measures showed CB > NCB and RBT > CBT. The lower performance measures for CB were likely due to an increase in the net external load when the barbell accelerates faster than the gravitational constant causing the counter-balance weight becomes ineffective."],"dc:format":["Text"],"dc:identifier":["doi: 10.12794/metadc67963","https://digital.library.unt.edu/ark:/67531/metadc67963/","ark: ark:/67531/metadc67963"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Copyright","Buddhadev, Harsh","Copyright is held by the author, unless otherwise noted. All rights reserved."],"dc:subject":["bench press throw","counter-balanced","linear accelerometer","peak power","Smith machine"],"dc:title":["Mechanisms Affecting Bench Press Throw Performance while Using a Counter-Balanced Smith Machine"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:46:55Z"}