{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc699876"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc699876","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Measuring Biomarkers From Dried Blood Spots Utilizing Bead-based Multiplex Technology","abstract":"Dried blood spots is an alternative method to collect blood samples from research subjects. However, little is known about how hemoglobin and hematocrit affect bead-based multiplex assay performance. The purpose of this study was to determine how bead-based multiplex assays perform when analyzing dried blood spot samples. A series of four experiments outline the study each with a specific purpose. A total of 167 subject samples were collected and 92 different biomarkers were measured. Median fluorescence intensity results show a positive correlation between filtered and non-filtered samples. Utilizing a smaller quantity of sample results in a positive correlation to a larger sample. Removal of hemoglobin from the dried blood spot sample does not increase detection or concentration of biomarkers. Of the 92 different biomarkers measured 56 were detectable in 100-75% of the attempted samples. We conclude that blood biomarkers can be detected using bead-based multiplex assays. In addition, it is possible to utilize a smaller quantity of sample while avoiding the use of the entire sample, and maintaining a correlation to the total sample. While our method of hemoglobin was efficient it also removed the biomarkers we wished to analyze. Thus, an alternative method is necessary to determine if removing hemoglobin increases concentration of biomarkers. More research is necessary to determine if the biomarkers measured in this study can be measured over time or within an experimental model.","abstract_html":"Dried blood spots is an alternative method to collect blood samples from research subjects. However, little is known about how hemoglobin and hematocrit affect bead-based multiplex assay performance. The purpose of this study was to determine how bead-based multiplex assays perform when analyzing dried blood spot samples. A series of four experiments outline the study each with a specific purpose. A total of 167 subject samples were collected and 92 different biomarkers were measured. Median fluorescence intensity results show a positive correlation between filtered and non-filtered samples. Utilizing a smaller quantity of sample results in a positive correlation to a larger sample. Removal of hemoglobin from the dried blood spot sample does not increase detection or concentration of biomarkers. Of the 92 different biomarkers measured 56 were detectable in 100-75% of the attempted samples. We conclude that blood biomarkers can be detected using bead-based multiplex assays. In addition, it is possible to utilize a smaller quantity of sample while avoiding the use of the entire sample, and maintaining a correlation to the total sample. While our method of hemoglobin was efficient it also removed the biomarkers we wished to analyze. Thus, an alternative method is necessary to determine if removing hemoglobin increases concentration of biomarkers. More research is necessary to determine if the biomarkers measured in this study can be measured over time or within an experimental model.","abstract_has_math":false,"creators":["Prado, Eric A."],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["McFarlin, Brian","Vingren, Jakob L.","Hill, David Wilfred, 1952-","Dzialowski, Edward M. (Edward Michael)"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-12","date_published":"2014-12","updated_at":"2026-11-19T08:54:20Z","subjects":["DBS","biomarkers","hemoglobin","bead-based multiplex assays","fluorescence intensity","Biochemical markers.","Blood -- Collection and preservation.","Hematology."],"languages":["English"],"rights":["Public","Prado, Eric A.","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digital.library.unt.edu/ark:/67531/metadc699876/","ark: ark:/67531/metadc699876"],"render_values":[{"text":"https://digital.library.unt.edu/ark:/67531/metadc699876/","href":"https://digital.library.unt.edu/ark:/67531/metadc699876/","code":true},{"text":"ark: ark:/67531/metadc699876","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.12794/metadc699876","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.12794/metadc699876","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc699876","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["McFarlin, Brian","Vingren, Jakob L.","Hill, David Wilfred, 1952-","Dzialowski, Edward M. (Edward Michael)"]},{"key":"dc:creator","label":"Author","values":["Prado, Eric A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-12"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["DBS","biomarkers","hemoglobin","bead-based multiplex assays","fluorescence intensity","Biochemical markers.","Blood -- Collection and preservation.","Hematology."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Prado, Eric A.","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["doi: 10.12794/metadc699876","https://digital.library.unt.edu/ark:/67531/metadc699876/","ark: ark:/67531/metadc699876"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Dried blood spots is an alternative method to collect blood samples from research subjects. However, little is known about how hemoglobin and hematocrit affect bead-based multiplex assay performance. The purpose of this study was to determine how bead-based multiplex assays perform when analyzing dried blood spot samples. A series of four experiments outline the study each with a specific purpose. A total of 167 subject samples were collected and 92 different biomarkers were measured. Median fluorescence intensity results show a positive correlation between filtered and non-filtered samples. Utilizing a smaller quantity of sample results in a positive correlation to a larger sample. Removal of hemoglobin from the dried blood spot sample does not increase detection or concentration of biomarkers. Of the 92 different biomarkers measured 56 were detectable in 100-75% of the attempted samples. We conclude that blood biomarkers can be detected using bead-based multiplex assays. In addition, it is possible to utilize a smaller quantity of sample while avoiding the use of the entire sample, and maintaining a correlation to the total sample. While our method of hemoglobin was efficient it also removed the biomarkers we wished to analyze. Thus, an alternative method is necessary to determine if removing hemoglobin increases concentration of biomarkers. More research is necessary to determine if the biomarkers measured in this study can be measured over time or within an experimental model."]},{"key":"dc:format","label":"Dc Format","values":["vi, 30 pages : illustrations","Text"]},{"key":"dc:title","label":"Title","values":["Measuring Biomarkers From Dried Blood Spots Utilizing Bead-based Multiplex Technology"]}]}],"canonical_facts":{"dc:contributor":["McFarlin, Brian","Vingren, Jakob L.","Hill, David Wilfred, 1952-","Dzialowski, Edward M. (Edward Michael)"],"dc:creator":["Prado, Eric A."],"dc:date":["2014-12"],"dc:description":["Dried blood spots is an alternative method to collect blood samples from research subjects. However, little is known about how hemoglobin and hematocrit affect bead-based multiplex assay performance. The purpose of this study was to determine how bead-based multiplex assays perform when analyzing dried blood spot samples. A series of four experiments outline the study each with a specific purpose. A total of 167 subject samples were collected and 92 different biomarkers were measured. Median fluorescence intensity results show a positive correlation between filtered and non-filtered samples. Utilizing a smaller quantity of sample results in a positive correlation to a larger sample. Removal of hemoglobin from the dried blood spot sample does not increase detection or concentration of biomarkers. Of the 92 different biomarkers measured 56 were detectable in 100-75% of the attempted samples. We conclude that blood biomarkers can be detected using bead-based multiplex assays. In addition, it is possible to utilize a smaller quantity of sample while avoiding the use of the entire sample, and maintaining a correlation to the total sample. While our method of hemoglobin was efficient it also removed the biomarkers we wished to analyze. Thus, an alternative method is necessary to determine if removing hemoglobin increases concentration of biomarkers. More research is necessary to determine if the biomarkers measured in this study can be measured over time or within an experimental model."],"dc:format":["vi, 30 pages : illustrations","Text"],"dc:identifier":["doi: 10.12794/metadc699876","https://digital.library.unt.edu/ark:/67531/metadc699876/","ark: ark:/67531/metadc699876"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Prado, Eric A.","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."],"dc:subject":["DBS","biomarkers","hemoglobin","bead-based multiplex assays","fluorescence intensity","Biochemical markers.","Blood -- Collection and preservation.","Hematology."],"dc:title":["Measuring Biomarkers From Dried Blood Spots Utilizing Bead-based Multiplex Technology"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:54:20Z"}