{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc849682"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc849682","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Evaluating the Pulse Sensor as a Low-Cost and Portable Measurement of Blood Pulse Waveform","abstract":"This study was aimed at determining whether the digital volume pulse waveform using the Pulse Sensor can be used to extract features related to arterial compliance. The Pulse Sensor, a low-cost photoplethysmograph, measures green light reflection in the finger and generates output, which is indicative of blood flow and can be read by the low-cost Arduino UNO™. The Pulse Sensor code was modified to increase the sampling frequency and to capture the data in a file, which is subsequently used for waveform analysis using programs written in the R system. Waveforms were obtained using the Pulse Sensor during two 30-s periods of seated rest, in each of 44 participants, who were between the ages of 20 and 80 years. For each cardiac cycle, the first four derivatives of the waveform were calculated and low-pass filtered by convolution before every differentiation step. The program was written to extract 19 features from the pulse waveform and its derivatives. These features were selected from those that have been reported to relate to the physiopathology of hemodynamics. Results indicate that subtle features of the pulse waveform can be calculated from the fourth derivative. Feature misidentification occurred in cases of saturation or low voltage and resulted in outliers; therefore, trimmed means of the features were calculated by automatically discarding the outliers. There was a high efficiency of extraction for most features. Significant relationships were found between several of the features and age, and systolic, diastolic, and mean arterial blood pressure, suggesting that these features might be employed to predict arterial compliance. Further improvements in experimental design could lead to a more detailed evaluation of the Pulse Sensor with respect to its capability to predict factors related to arterial compliance.","abstract_html":"This study was aimed at determining whether the digital volume pulse waveform using the Pulse Sensor can be used to extract features related to arterial compliance. The Pulse Sensor, a low-cost photoplethysmograph, measures green light reflection in the finger and generates output, which is indicative of blood flow and can be read by the low-cost Arduino UNO™. The Pulse Sensor code was modified to increase the sampling frequency and to capture the data in a file, which is subsequently used for waveform analysis using programs written in the R system. Waveforms were obtained using the Pulse Sensor during two 30-s periods of seated rest, in each of 44 participants, who were between the ages of 20 and 80 years. For each cardiac cycle, the first four derivatives of the waveform were calculated and low-pass filtered by convolution before every differentiation step. The program was written to extract 19 features from the pulse waveform and its derivatives. These features were selected from those that have been reported to relate to the physiopathology of hemodynamics. Results indicate that subtle features of the pulse waveform can be calculated from the fourth derivative. Feature misidentification occurred in cases of saturation or low voltage and resulted in outliers; therefore, trimmed means of the features were calculated by automatically discarding the outliers. There was a high efficiency of extraction for most features. Significant relationships were found between several of the features and age, and systolic, diastolic, and mean arterial blood pressure, suggesting that these features might be employed to predict arterial compliance. Further improvements in experimental design could lead to a more detailed evaluation of the Pulse Sensor with respect to its capability to predict factors related to arterial compliance.","abstract_has_math":false,"creators":["Smithers, Breana Gray"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Hill, David Wilfred, 1952-","Vingren, Jakob L.","Fu, Shengli"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-05","date_published":"2016-05","updated_at":"2026-11-19T08:54:28Z","subjects":["pulse wave","arterial compliance","photoplethysmograph","blood pressure","Pulse Sensor","Blood -- Circulation.","Arteries -- Mechanical properties.","Blood pressure -- Measurement."],"languages":["English"],"rights":["Public","Smithers, Breana Gray","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_164","https://digital.library.unt.edu/ark:/67531/metadc849682/","ark: ark:/67531/metadc849682"],"render_values":[{"text":"local-cont-no: submission_164","href":null,"code":true},{"text":"https://digital.library.unt.edu/ark:/67531/metadc849682/","href":"https://digital.library.unt.edu/ark:/67531/metadc849682/","code":true},{"text":"ark: ark:/67531/metadc849682","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.12794/metadc849682","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.12794/metadc849682","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc849682","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Hill, David Wilfred, 1952-","Vingren, Jakob L.","Fu, Shengli"]},{"key":"dc:creator","label":"Author","values":["Smithers, Breana Gray"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-05"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["pulse wave","arterial compliance","photoplethysmograph","blood pressure","Pulse Sensor","Blood -- Circulation.","Arteries -- Mechanical properties.","Blood pressure -- Measurement."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Smithers, Breana Gray","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_164","doi: 10.12794/metadc849682","https://digital.library.unt.edu/ark:/67531/metadc849682/","ark: ark:/67531/metadc849682"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This study was aimed at determining whether the digital volume pulse waveform using the Pulse Sensor can be used to extract features related to arterial compliance. The Pulse Sensor, a low-cost photoplethysmograph, measures green light reflection in the finger and generates output, which is indicative of blood flow and can be read by the low-cost Arduino UNO™. The Pulse Sensor code was modified to increase the sampling frequency and to capture the data in a file, which is subsequently used for waveform analysis using programs written in the R system. Waveforms were obtained using the Pulse Sensor during two 30-s periods of seated rest, in each of 44 participants, who were between the ages of 20 and 80 years. For each cardiac cycle, the first four derivatives of the waveform were calculated and low-pass filtered by convolution before every differentiation step. The program was written to extract 19 features from the pulse waveform and its derivatives. These features were selected from those that have been reported to relate to the physiopathology of hemodynamics. Results indicate that subtle features of the pulse waveform can be calculated from the fourth derivative. Feature misidentification occurred in cases of saturation or low voltage and resulted in outliers; therefore, trimmed means of the features were calculated by automatically discarding the outliers. There was a high efficiency of extraction for most features. Significant relationships were found between several of the features and age, and systolic, diastolic, and mean arterial blood pressure, suggesting that these features might be employed to predict arterial compliance. Further improvements in experimental design could lead to a more detailed evaluation of the Pulse Sensor with respect to its capability to predict factors related to arterial compliance."]},{"key":"dc:format","label":"Dc Format","values":["iv, 36 pages : illustrations","Text"]},{"key":"dc:title","label":"Title","values":["Evaluating the Pulse Sensor as a Low-Cost and Portable Measurement of Blood Pulse Waveform"]}]}],"canonical_facts":{"dc:contributor":["Hill, David Wilfred, 1952-","Vingren, Jakob L.","Fu, Shengli"],"dc:creator":["Smithers, Breana Gray"],"dc:date":["2016-05"],"dc:description":["This study was aimed at determining whether the digital volume pulse waveform using the Pulse Sensor can be used to extract features related to arterial compliance. The Pulse Sensor, a low-cost photoplethysmograph, measures green light reflection in the finger and generates output, which is indicative of blood flow and can be read by the low-cost Arduino UNO™. The Pulse Sensor code was modified to increase the sampling frequency and to capture the data in a file, which is subsequently used for waveform analysis using programs written in the R system. Waveforms were obtained using the Pulse Sensor during two 30-s periods of seated rest, in each of 44 participants, who were between the ages of 20 and 80 years. For each cardiac cycle, the first four derivatives of the waveform were calculated and low-pass filtered by convolution before every differentiation step. The program was written to extract 19 features from the pulse waveform and its derivatives. These features were selected from those that have been reported to relate to the physiopathology of hemodynamics. Results indicate that subtle features of the pulse waveform can be calculated from the fourth derivative. Feature misidentification occurred in cases of saturation or low voltage and resulted in outliers; therefore, trimmed means of the features were calculated by automatically discarding the outliers. There was a high efficiency of extraction for most features. Significant relationships were found between several of the features and age, and systolic, diastolic, and mean arterial blood pressure, suggesting that these features might be employed to predict arterial compliance. Further improvements in experimental design could lead to a more detailed evaluation of the Pulse Sensor with respect to its capability to predict factors related to arterial compliance."],"dc:format":["iv, 36 pages : illustrations","Text"],"dc:identifier":["local-cont-no: submission_164","doi: 10.12794/metadc849682","https://digital.library.unt.edu/ark:/67531/metadc849682/","ark: ark:/67531/metadc849682"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Smithers, Breana Gray","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"dc:subject":["pulse wave","arterial compliance","photoplethysmograph","blood pressure","Pulse Sensor","Blood -- Circulation.","Arteries -- Mechanical properties.","Blood pressure -- Measurement."],"dc:title":["Evaluating the Pulse Sensor as a Low-Cost and Portable Measurement of Blood Pulse Waveform"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:54:28Z"}