{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc849747"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc849747","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Direct Inject Mass Spectrometry for Illicit Chemistry Detection and Characterization","abstract":"The field of direct inject mass spectrometry includes a massive host of ambient ionization techniques that are especially useful for forensic analysts. Whether the sample is trace amounts of drugs or explosives or bulk amounts of synthetic drugs from a clandestine laboratory, the analysis of forensic evidence requires minimal sample preparation, evidence preservation, and high sensitivity. Direct inject mass spectrometry techniques can rarely provide all of these. Direct analyte-probed nanoextraction coupled to nanospray ionization mass spectrometry, however, is certainly capable of achieving these goals. As a multifaceted tool developed in the Verbeck laboratory, many forensic applications have since been investigated (trace drug and explosives analysis). Direct inject mass spectrometry can also be easily coupled to assays to obtain additional information about the analytes in question. By performing a parallel artificial membrane assay or a cell membrane stationary phase extraction prior to direct infusion of the sample, membrane permeability data and receptor activity data can be obtained in addition to the mass spectral data that was already being collected. This is particularly useful for characterizing illicit drugs and their analogues for a biologically relevant way to schedule new psychoactive substances.","abstract_html":"The field of direct inject mass spectrometry includes a massive host of ambient ionization techniques that are especially useful for forensic analysts. Whether the sample is trace amounts of drugs or explosives or bulk amounts of synthetic drugs from a clandestine laboratory, the analysis of forensic evidence requires minimal sample preparation, evidence preservation, and high sensitivity. Direct inject mass spectrometry techniques can rarely provide all of these. Direct analyte-probed nanoextraction coupled to nanospray ionization mass spectrometry, however, is certainly capable of achieving these goals. As a multifaceted tool developed in the Verbeck laboratory, many forensic applications have since been investigated (trace drug and explosives analysis). Direct inject mass spectrometry can also be easily coupled to assays to obtain additional information about the analytes in question. By performing a parallel artificial membrane assay or a cell membrane stationary phase extraction prior to direct infusion of the sample, membrane permeability data and receptor activity data can be obtained in addition to the mass spectral data that was already being collected. This is particularly useful for characterizing illicit drugs and their analogues for a biologically relevant way to schedule new psychoactive substances.","abstract_has_math":false,"creators":["Williams, Kristina Charlene"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Verbeck, Guido F.","Golden, Teresa Diane, 1963-","Petros, Robby A.","Chapman, Kent Dean"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-05","date_published":"2016-05","updated_at":"2026-11-19T08:54:28Z","subjects":["Mass spectrometry","forensic research","direct analyte probed nanoextraction","illicit drugs","energetic materials","parallel artificial membrane permeability assay","cell membrane stationary phase","Analytical Chemistry","Mass spectrometry -- Forensic applications.","Drugs -- Analysis."],"languages":["English"],"rights":["Public","Williams, Kristina Charlene","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_87","https://digital.library.unt.edu/ark:/67531/metadc849747/","ark: ark:/67531/metadc849747"],"render_values":[{"text":"local-cont-no: submission_87","href":null,"code":true},{"text":"https://digital.library.unt.edu/ark:/67531/metadc849747/","href":"https://digital.library.unt.edu/ark:/67531/metadc849747/","code":true},{"text":"ark: ark:/67531/metadc849747","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.12794/metadc849747","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.12794/metadc849747","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc849747","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Verbeck, Guido F.","Golden, Teresa Diane, 1963-","Petros, Robby A.","Chapman, Kent Dean"]},{"key":"dc:creator","label":"Author","values":["Williams, Kristina Charlene"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-05"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mass spectrometry","forensic research","direct analyte probed nanoextraction","illicit drugs","energetic materials","parallel artificial membrane permeability assay","cell membrane stationary phase","Analytical Chemistry","Mass spectrometry -- Forensic applications.","Drugs -- Analysis."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Williams, Kristina Charlene","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_87","doi: 10.12794/metadc849747","https://digital.library.unt.edu/ark:/67531/metadc849747/","ark: ark:/67531/metadc849747"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The field of direct inject mass spectrometry includes a massive host of ambient ionization techniques that are especially useful for forensic analysts. Whether the sample is trace amounts of drugs or explosives or bulk amounts of synthetic drugs from a clandestine laboratory, the analysis of forensic evidence requires minimal sample preparation, evidence preservation, and high sensitivity. Direct inject mass spectrometry techniques can rarely provide all of these. Direct analyte-probed nanoextraction coupled to nanospray ionization mass spectrometry, however, is certainly capable of achieving these goals. As a multifaceted tool developed in the Verbeck laboratory, many forensic applications have since been investigated (trace drug and explosives analysis). Direct inject mass spectrometry can also be easily coupled to assays to obtain additional information about the analytes in question. By performing a parallel artificial membrane assay or a cell membrane stationary phase extraction prior to direct infusion of the sample, membrane permeability data and receptor activity data can be obtained in addition to the mass spectral data that was already being collected. This is particularly useful for characterizing illicit drugs and their analogues for a biologically relevant way to schedule new psychoactive substances."]},{"key":"dc:format","label":"Dc Format","values":["xiii, 125 pages : illustrations","Text"]},{"key":"dc:title","label":"Title","values":["Direct Inject Mass Spectrometry for Illicit Chemistry Detection and Characterization"]}]}],"canonical_facts":{"dc:contributor":["Verbeck, Guido F.","Golden, Teresa Diane, 1963-","Petros, Robby A.","Chapman, Kent Dean"],"dc:creator":["Williams, Kristina Charlene"],"dc:date":["2016-05"],"dc:description":["The field of direct inject mass spectrometry includes a massive host of ambient ionization techniques that are especially useful for forensic analysts. Whether the sample is trace amounts of drugs or explosives or bulk amounts of synthetic drugs from a clandestine laboratory, the analysis of forensic evidence requires minimal sample preparation, evidence preservation, and high sensitivity. Direct inject mass spectrometry techniques can rarely provide all of these. Direct analyte-probed nanoextraction coupled to nanospray ionization mass spectrometry, however, is certainly capable of achieving these goals. As a multifaceted tool developed in the Verbeck laboratory, many forensic applications have since been investigated (trace drug and explosives analysis). Direct inject mass spectrometry can also be easily coupled to assays to obtain additional information about the analytes in question. By performing a parallel artificial membrane assay or a cell membrane stationary phase extraction prior to direct infusion of the sample, membrane permeability data and receptor activity data can be obtained in addition to the mass spectral data that was already being collected. This is particularly useful for characterizing illicit drugs and their analogues for a biologically relevant way to schedule new psychoactive substances."],"dc:format":["xiii, 125 pages : illustrations","Text"],"dc:identifier":["local-cont-no: submission_87","doi: 10.12794/metadc849747","https://digital.library.unt.edu/ark:/67531/metadc849747/","ark: ark:/67531/metadc849747"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Williams, Kristina Charlene","Copyright","Copyright is held by the author, unless otherwise noted. All rights reserved."],"dc:subject":["Mass spectrometry","forensic research","direct analyte probed nanoextraction","illicit drugs","energetic materials","parallel artificial membrane permeability assay","cell membrane stationary phase","Analytical Chemistry","Mass spectrometry -- Forensic applications.","Drugs -- Analysis."],"dc:title":["Direct Inject Mass Spectrometry for Illicit Chemistry Detection and Characterization"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:54:28Z"}