{"id":{"repo_id":"unt","oai_identifier":"info:ark/67531/metadc849775"},"canonical_url":"https://search.ndltd.org/etd/unt/info:ark/67531/metadc849775","repository":{"repo_id":"unt","name":"University of North Texas","base_url":"https://digital.library.unt.edu/oai/"},"display":{"title":"Accelerated Corrosion Test with Operation Simulation of All-Aluminum Microchannel Heat Exchangers","abstract":"The HVAC&R industry is looking to transition from copper-aluminum heat exchangers to all-aluminum microchannel technology. The want for the transition stemmed from seeing the performance improvement of all-aluminum microchannel radiators in the automotive industry. Applications differ between the two industries; therefore, applying this technology for HVAC&R use must be validated. Research towards operating modes of an all-aluminum heat exchanger in a defined corrosive environment will provide the industry with a better understanding of heat exchanger design and heat exchanger material selection. The worth in this is preventing overdesign and producing more efficient heat exchangers. Furthermore, ASHRAE members and the corrosion community will find value in a defined corrosion system and corrosion test procedure. The information gained through past research has progressed assessment of material performance; however, the methods improperly simulate and expedite natural weathering. The most common method being used is the ASTM (American Society of Testing Materials) Sea Water Acetic Acid Test. The research discussed in this paper was focused on improving a standard corrosion system by implementing system modifications to simulate heat exchanger operation while performing a modified wet-dry cyclic test (e.g. ASTM G85 Annex 5). The goal is to produce results that are more representative of natural corrosion behavior and its forms. Current results were gathered from five of ten samples that underwent initial testing. Finally, possible improvements towards the chamber system and the test method, including the salt solution, are discussed.","abstract_html":"The HVAC&amp;R industry is looking to transition from copper-aluminum heat exchangers to all-aluminum microchannel technology. The want for the transition stemmed from seeing the performance improvement of all-aluminum microchannel radiators in the automotive industry. Applications differ between the two industries; therefore, applying this technology for HVAC&amp;R use must be validated. Research towards operating modes of an all-aluminum heat exchanger in a defined corrosive environment will provide the industry with a better understanding of heat exchanger design and heat exchanger material selection. The worth in this is preventing overdesign and producing more efficient heat exchangers. Furthermore, ASHRAE members and the corrosion community will find value in a defined corrosion system and corrosion test procedure. The information gained through past research has progressed assessment of material performance; however, the methods improperly simulate and expedite natural weathering. The most common method being used is the ASTM (American Society of Testing Materials) Sea Water Acetic Acid Test. The research discussed in this paper was focused on improving a standard corrosion system by implementing system modifications to simulate heat exchanger operation while performing a modified wet-dry cyclic test (e.g. ASTM G85 Annex 5). The goal is to produce results that are more representative of natural corrosion behavior and its forms. Current results were gathered from five of ten samples that underwent initial testing. Finally, possible improvements towards the chamber system and the test method, including the salt solution, are discussed.","abstract_has_math":false,"creators":["Vaughan, Haydn"],"institution":"University of North Texas","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Nasrzadani, Seifollah","Bostanci, Huseyin","Zhang, Haifeng"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-05","date_published":"2016-05","updated_at":"2026-11-19T08:54:28Z","subjects":["All-Aluminum","Microchannel","heat exchanger","corrosion","heat exchanger operation"],"languages":["English"],"rights":["Public","Vaughan, Haydn","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_250","https://digital.library.unt.edu/ark:/67531/metadc849775/","ark: ark:/67531/metadc849775"],"render_values":[{"text":"local-cont-no: submission_250","href":null,"code":true},{"text":"https://digital.library.unt.edu/ark:/67531/metadc849775/","href":"https://digital.library.unt.edu/ark:/67531/metadc849775/","code":true},{"text":"ark: ark:/67531/metadc849775","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.12794/metadc849775","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.12794/metadc849775","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digital.library.unt.edu/oai/?verb=GetRecord&metadataPrefix=oai_dc&identifier=info%3Aark%2F67531%2Fmetadc849775","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Nasrzadani, Seifollah","Bostanci, Huseyin","Zhang, Haifeng"]},{"key":"dc:creator","label":"Author","values":["Vaughan, Haydn"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-05"]},{"key":"dc:publisher","label":"Institution","values":["University of North Texas"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["All-Aluminum","Microchannel","heat exchanger","corrosion","heat exchanger operation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public","Vaughan, Haydn","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["local-cont-no: submission_250","doi: 10.12794/metadc849775","https://digital.library.unt.edu/ark:/67531/metadc849775/","ark: ark:/67531/metadc849775"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The HVAC&R industry is looking to transition from copper-aluminum heat exchangers to all-aluminum microchannel technology. The want for the transition stemmed from seeing the performance improvement of all-aluminum microchannel radiators in the automotive industry. Applications differ between the two industries; therefore, applying this technology for HVAC&R use must be validated. Research towards operating modes of an all-aluminum heat exchanger in a defined corrosive environment will provide the industry with a better understanding of heat exchanger design and heat exchanger material selection. The worth in this is preventing overdesign and producing more efficient heat exchangers. Furthermore, ASHRAE members and the corrosion community will find value in a defined corrosion system and corrosion test procedure. The information gained through past research has progressed assessment of material performance; however, the methods improperly simulate and expedite natural weathering. The most common method being used is the ASTM (American Society of Testing Materials) Sea Water Acetic Acid Test. The research discussed in this paper was focused on improving a standard corrosion system by implementing system modifications to simulate heat exchanger operation while performing a modified wet-dry cyclic test (e.g. ASTM G85 Annex 5). The goal is to produce results that are more representative of natural corrosion behavior and its forms. Current results were gathered from five of ten samples that underwent initial testing. Finally, possible improvements towards the chamber system and the test method, including the salt solution, are discussed."]},{"key":"dc:format","label":"Dc Format","values":["Text"]},{"key":"dc:title","label":"Title","values":["Accelerated Corrosion Test with Operation Simulation of All-Aluminum Microchannel Heat Exchangers"]}]}],"canonical_facts":{"dc:contributor":["Nasrzadani, Seifollah","Bostanci, Huseyin","Zhang, Haifeng"],"dc:creator":["Vaughan, Haydn"],"dc:date":["2016-05"],"dc:description":["The HVAC&R industry is looking to transition from copper-aluminum heat exchangers to all-aluminum microchannel technology. The want for the transition stemmed from seeing the performance improvement of all-aluminum microchannel radiators in the automotive industry. Applications differ between the two industries; therefore, applying this technology for HVAC&R use must be validated. Research towards operating modes of an all-aluminum heat exchanger in a defined corrosive environment will provide the industry with a better understanding of heat exchanger design and heat exchanger material selection. The worth in this is preventing overdesign and producing more efficient heat exchangers. Furthermore, ASHRAE members and the corrosion community will find value in a defined corrosion system and corrosion test procedure. The information gained through past research has progressed assessment of material performance; however, the methods improperly simulate and expedite natural weathering. The most common method being used is the ASTM (American Society of Testing Materials) Sea Water Acetic Acid Test. The research discussed in this paper was focused on improving a standard corrosion system by implementing system modifications to simulate heat exchanger operation while performing a modified wet-dry cyclic test (e.g. ASTM G85 Annex 5). The goal is to produce results that are more representative of natural corrosion behavior and its forms. Current results were gathered from five of ten samples that underwent initial testing. Finally, possible improvements towards the chamber system and the test method, including the salt solution, are discussed."],"dc:format":["Text"],"dc:identifier":["local-cont-no: submission_250","doi: 10.12794/metadc849775","https://digital.library.unt.edu/ark:/67531/metadc849775/","ark: ark:/67531/metadc849775"],"dc:language":["English"],"dc:publisher":["University of North Texas"],"dc:rights":["Public","Vaughan, Haydn","Copyright","Copyright is held by the author, unless otherwise noted. All rights Reserved."],"dc:subject":["All-Aluminum","Microchannel","heat exchanger","corrosion","heat exchanger operation"],"dc:title":["Accelerated Corrosion Test with Operation Simulation of All-Aluminum Microchannel Heat Exchangers"],"dc:type":["Thesis or Dissertation"]},"updated_at":"2026-11-19T08:54:28Z"}