{"id":{"repo_id":"uoit","oai_identifier":"oai:ontariotechu.scholaris.ca:10155/2138"},"canonical_url":"https://search.ndltd.org/etd/uoit/oai:ontariotechu.scholaris.ca:10155/2138","repository":{"repo_id":"uoit","name":"Ontario Institute of Technology","base_url":"https://ontariotechu.scholaris.ca/server/oai/request"},"display":{"title":"Experimental investigation of simultaneous hydrogen production and sodium hypochlorite formation in a carbon-based saline water electrolysis system","abstract":"Due to the increasing demand for sustainable and efficient hydrogen production, electrochemical methods capable of concurrently producing hydrogen and valuable chemicals are gaining attention. This study investigates the simultaneous production of hydrogen and sodium hypochlorite through saline water electrolysis. The effects of applied voltage, NaCl concentration, temperature, electrolysis time, and current distribution method are examined. Hydrogen production and active chlorine formation increase with applied voltage and NaCl concentration. The maximum production occurs at 0.7 M NaCl, 30°C, and 5 V, yielding 34.02 mL of H₂ and an estimated 73.20 mg of NaOCl based on the measured active chlorine concentration. The maximum Faradaic efficiency of hydrogen production is 26.92% at 4 V, while the maximum active chlorine current efficiency is 23.69% at 5 V, both at 0.7 M NaCl and 10°C. The maximum overall exergy efficiency is 12.76% at 4 V. Activated-carbon-assisted current distribution outperforms direct copper-wire contact.","abstract_html":"Due to the increasing demand for sustainable and efficient hydrogen production, electrochemical methods capable of concurrently producing hydrogen and valuable chemicals are gaining attention. This study investigates the simultaneous production of hydrogen and sodium hypochlorite through saline water electrolysis. The effects of applied voltage, NaCl concentration, temperature, electrolysis time, and current distribution method are examined. Hydrogen production and active chlorine formation increase with applied voltage and NaCl concentration. The maximum production occurs at 0.7 M NaCl, 30°C, and 5 V, yielding 34.02 mL of H₂ and an estimated 73.20 mg of NaOCl based on the measured active chlorine concentration. The maximum Faradaic efficiency of hydrogen production is 26.92% at 4 V, while the maximum active chlorine current efficiency is 23.69% at 5 V, both at 0.7 M NaCl and 10°C. The maximum overall exergy efficiency is 12.76% at 4 V. Activated-carbon-assisted current distribution outperforms direct copper-wire contact.","abstract_has_math":false,"creators":["Elmali, Sevde"],"institution":"University of Ontario Institute of Technology","degree_name":"Master of Applied Science (MASc)","degree_level":null,"degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Dincer, Ibrahim"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-08-01","date_published":"2026-08-01","updated_at":"2026-11-19T09:01:52Z","subjects":["Hydrogen production","Sodium hypochlorite","Saline water electrolysis","Activated carbon","Faradaic efficiency"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10155/2138","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10155/2138","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Auoit%3Aoai%3Aontariotechu.scholaris.ca%3A10155%2F2138","prefix":"oai_dc"},"source_record":{"url":"https://ontariotechu.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aontariotechu.scholaris.ca%3A10155%2F2138","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dincer, Ibrahim"]},{"key":"dc:creator","label":"Author","values":["Elmali, Sevde"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-01T16:25:11Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-08-01"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (MASc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Ontario Institute of Technology"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.other","label":"Dc Subject Other","values":["Hydrogen production","Sodium hypochlorite","Saline water electrolysis","Activated carbon","Faradaic efficiency"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10155/2138"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Due to the increasing demand for sustainable and efficient hydrogen production, electrochemical methods capable of concurrently producing hydrogen and valuable chemicals are gaining attention. This study investigates the simultaneous production of hydrogen and sodium hypochlorite through saline water electrolysis. The effects of applied voltage, NaCl concentration, temperature, electrolysis time, and current distribution method are examined. Hydrogen production and active chlorine formation increase with applied voltage and NaCl concentration. The maximum production occurs at 0.7 M NaCl, 30°C, and 5 V, yielding 34.02 mL of H₂ and an estimated 73.20 mg of NaOCl based on the measured active chlorine concentration. The maximum Faradaic efficiency of hydrogen production is 26.92% at 4 V, while the maximum active chlorine current efficiency is 23.69% at 5 V, both at 0.7 M NaCl and 10°C. The maximum overall exergy efficiency is 12.76% at 4 V. Activated-carbon-assisted current distribution outperforms direct copper-wire contact."]},{"key":"dc:title","label":"Title","values":["Experimental investigation of simultaneous hydrogen production and sodium hypochlorite formation in a carbon-based saline water electrolysis system"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dincer, Ibrahim"],"dc:creator":["Elmali, Sevde"],"dc:date.accessioned":["2026-09-01T16:25:11Z"],"dc:date.issued":["2026-08-01"],"dc:description.abstract":["Due to the increasing demand for sustainable and efficient hydrogen production, electrochemical methods capable of concurrently producing hydrogen and valuable chemicals are gaining attention. This study investigates the simultaneous production of hydrogen and sodium hypochlorite through saline water electrolysis. The effects of applied voltage, NaCl concentration, temperature, electrolysis time, and current distribution method are examined. Hydrogen production and active chlorine formation increase with applied voltage and NaCl concentration. The maximum production occurs at 0.7 M NaCl, 30°C, and 5 V, yielding 34.02 mL of H₂ and an estimated 73.20 mg of NaOCl based on the measured active chlorine concentration. The maximum Faradaic efficiency of hydrogen production is 26.92% at 4 V, while the maximum active chlorine current efficiency is 23.69% at 5 V, both at 0.7 M NaCl and 10°C. The maximum overall exergy efficiency is 12.76% at 4 V. Activated-carbon-assisted current distribution outperforms direct copper-wire contact."],"dc:identifier.uri":["https://hdl.handle.net/10155/2138"],"dc:language.iso":["en"],"dc:subject.other":["Hydrogen production","Sodium hypochlorite","Saline water electrolysis","Activated carbon","Faradaic efficiency"],"dc:title":["Experimental investigation of simultaneous hydrogen production and sodium hypochlorite formation in a carbon-based saline water electrolysis system"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_name":["Master of Applied Science (MASc)"],"thesis:institution_name":["University of Ontario Institute of Technology"]},"updated_at":"2026-11-19T09:01:52Z"}