{"id":{"repo_id":"uoit","oai_identifier":"oai:ontariotechu.scholaris.ca:10155/2148"},"canonical_url":"https://search.ndltd.org/etd/uoit/oai:ontariotechu.scholaris.ca:10155/2148","repository":{"repo_id":"uoit","name":"Ontario Institute of Technology","base_url":"https://ontariotechu.scholaris.ca/server/oai/request"},"display":{"title":"Refining eye-lens dosimetry using optically stimulated luminescent dosimeters under updated regulatory dose limits","abstract":"This study evaluates optically stimulated luminescence Dosimeters (OSLDs) for occupational eye-lens dosimetry under updated dose limits. In Canada, Thermoluminescent Dosimeters remain commonly used for eye-lens monitoring, but their heat-based readout erases stored dose information, resulting in the inability to re-read for verification. OSLDs provide high sensitivity, rapid readout, and low fading, yet require effective annealing before reuse because residual signal can remain after irradiation. OSLDs were exposed to low-, intermediate-, and high-energy photon and beta fields to assess whether the shallow dose quantity, Hp(0.07), can serve as an operational surrogate for Hp(3). A custom optical annealer was also developed and evaluated for residual signal removal and sensitivity restoration. Results show that Hp(0.07)-calibrated OSLDs provide a conservative surrogate for Hp(3) under EURADOS-relevant photon conditions. The annealer restored detector response to within ±3% of baseline after approximately 50–75 minutes of optical stimulation, supporting controlled OSLD reuse.","abstract_html":"This study evaluates optically stimulated luminescence Dosimeters (OSLDs) for occupational eye-lens dosimetry under updated dose limits. In Canada, Thermoluminescent Dosimeters remain commonly used for eye-lens monitoring, but their heat-based readout erases stored dose information, resulting in the inability to re-read for verification. OSLDs provide high sensitivity, rapid readout, and low fading, yet require effective annealing before reuse because residual signal can remain after irradiation. OSLDs were exposed to low-, intermediate-, and high-energy photon and beta fields to assess whether the shallow dose quantity, Hp(0.07), can serve as an operational surrogate for Hp(3). A custom optical annealer was also developed and evaluated for residual signal removal and sensitivity restoration. Results show that Hp(0.07)-calibrated OSLDs provide a conservative surrogate for Hp(3) under EURADOS-relevant photon conditions. The annealer restored detector response to within ±3% of baseline after approximately 50–75 minutes of optical stimulation, supporting controlled OSLD reuse.","abstract_has_math":false,"creators":["Manzoor, Minahil Tahir"],"institution":"University of Ontario Institute of Technology","degree_name":"Master of Applied Science (MASc)","degree_level":null,"degree_discipline":"Nuclear Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Waller, Edward"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-08-01","date_published":"2026-08-01","updated_at":"2026-11-19T09:00:56Z","subjects":["Eye-lens dosimetry","OSLD","Hp(0.07)","Hp(3)","Optical annealing"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10155/2148","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10155/2148","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Auoit%3Aoai%3Aontariotechu.scholaris.ca%3A10155%2F2148","prefix":"oai_dc"},"source_record":{"url":"https://ontariotechu.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aontariotechu.scholaris.ca%3A10155%2F2148","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Waller, Edward"]},{"key":"dc:creator","label":"Author","values":["Manzoor, Minahil Tahir"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-01T19:01:25Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-08-01"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Nuclear Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (MASc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Ontario Institute of Technology"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.other","label":"Dc Subject Other","values":["Eye-lens dosimetry","OSLD","Hp(0.07)","Hp(3)","Optical annealing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10155/2148"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study evaluates optically stimulated luminescence Dosimeters (OSLDs) for occupational eye-lens dosimetry under updated dose limits. In Canada, Thermoluminescent Dosimeters remain commonly used for eye-lens monitoring, but their heat-based readout erases stored dose information, resulting in the inability to re-read for verification. OSLDs provide high sensitivity, rapid readout, and low fading, yet require effective annealing before reuse because residual signal can remain after irradiation. OSLDs were exposed to low-, intermediate-, and high-energy photon and beta fields to assess whether the shallow dose quantity, Hp(0.07), can serve as an operational surrogate for Hp(3). A custom optical annealer was also developed and evaluated for residual signal removal and sensitivity restoration. Results show that Hp(0.07)-calibrated OSLDs provide a conservative surrogate for Hp(3) under EURADOS-relevant photon conditions. The annealer restored detector response to within ±3% of baseline after approximately 50–75 minutes of optical stimulation, supporting controlled OSLD reuse."]},{"key":"dc:title","label":"Title","values":["Refining eye-lens dosimetry using optically stimulated luminescent dosimeters under updated regulatory dose limits"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Waller, Edward"],"dc:creator":["Manzoor, Minahil Tahir"],"dc:date.accessioned":["2026-09-01T19:01:25Z"],"dc:date.issued":["2026-08-01"],"dc:description.abstract":["This study evaluates optically stimulated luminescence Dosimeters (OSLDs) for occupational eye-lens dosimetry under updated dose limits. In Canada, Thermoluminescent Dosimeters remain commonly used for eye-lens monitoring, but their heat-based readout erases stored dose information, resulting in the inability to re-read for verification. OSLDs provide high sensitivity, rapid readout, and low fading, yet require effective annealing before reuse because residual signal can remain after irradiation. OSLDs were exposed to low-, intermediate-, and high-energy photon and beta fields to assess whether the shallow dose quantity, Hp(0.07), can serve as an operational surrogate for Hp(3). A custom optical annealer was also developed and evaluated for residual signal removal and sensitivity restoration. Results show that Hp(0.07)-calibrated OSLDs provide a conservative surrogate for Hp(3) under EURADOS-relevant photon conditions. The annealer restored detector response to within ±3% of baseline after approximately 50–75 minutes of optical stimulation, supporting controlled OSLD reuse."],"dc:identifier.uri":["https://hdl.handle.net/10155/2148"],"dc:language.iso":["en"],"dc:subject.other":["Eye-lens dosimetry","OSLD","Hp(0.07)","Hp(3)","Optical annealing"],"dc:title":["Refining eye-lens dosimetry using optically stimulated luminescent dosimeters under updated regulatory dose limits"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Nuclear Engineering"],"thesis:degree_name":["Master of Applied Science (MASc)"],"thesis:institution_name":["University of Ontario Institute of Technology"]},"updated_at":"2026-11-19T09:00:56Z"}