{"id":{"repo_id":"uoit","oai_identifier":"oai:ontariotechu.scholaris.ca:10155/67"},"canonical_url":"https://search.ndltd.org/etd/uoit/oai:ontariotechu.scholaris.ca:10155/67","repository":{"repo_id":"uoit","name":"Ontario Institute of Technology","base_url":"https://ontariotechu.scholaris.ca/server/oai/request"},"display":{"title":"Dynamic flowgraph methodology for reliability modelling of networked control systems: with application to a nuclear-based hydrogen production plant","abstract":"The use of communication networks in digital control systems introduces stability and reliability concerns. Standard reliability and safety assessment methods need further modification to accommodate the issue in the reliability assessment of networked control systems. In this thesis, it is demonstrated that the Dynamic Flowgraph Methodology (DFM) can be extended to model networked control systems. The modelling of the communication network influence on the performance of the control system is presented. The areas that can affect the reliability of the control system are identified using the methodology. The thesis also presents the application of the DFM to a nuclear-based thermochemical water splitting process for hydrogen production, the Copper-Chlorine (Cu-Cl) cycle. The architecture of a networked control system and configuration of instrumentation and control systems for the hydrogen production plant are proposed in the thesis.","abstract_html":"The use of communication networks in digital control systems introduces stability and reliability concerns. Standard reliability and safety assessment methods need further modification to accommodate the issue in the reliability assessment of networked control systems. In this thesis, it is demonstrated that the Dynamic Flowgraph Methodology (DFM) can be extended to model networked control systems. The modelling of the communication network influence on the performance of the control system is presented. The areas that can affect the reliability of the control system are identified using the methodology. The thesis also presents the application of the DFM to a nuclear-based thermochemical water splitting process for hydrogen production, the Copper-Chlorine (Cu-Cl) cycle. The architecture of a networked control system and configuration of instrumentation and control systems for the hydrogen production plant are proposed in the thesis.","abstract_has_math":false,"creators":["Al-Dabbagh, Ahmad Wail"],"institution":"University of Ontario Institute of Technology","degree_name":"Master of Applied Science (MASc)","degree_level":"Master of Applied Science (MASc)","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Lu, Lixuan"],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-12-01","date_published":"2009-12-01","updated_at":"2026-11-19T09:02:19Z","subjects":["Dynamic flowgraph methodology","Networked control system","Cu-Cl cycle","Instrumentation and control systems","Communication network"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10155/67","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10155/67","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Auoit%3Aoai%3Aontariotechu.scholaris.ca%3A10155%2F67","prefix":"oai_dc"},"source_record":{"url":"https://ontariotechu.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aontariotechu.scholaris.ca%3A10155%2F67","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lu, Lixuan"]},{"key":"dc:creator","label":"Author","values":["Al-Dabbagh, Ahmad Wail"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-02-12T19:42:17Z","2022-03-29T16:34:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-02-12T19:42:17Z","2022-03-29T16:34:11Z"]},{"key":"dc:date.issued","label":"Date","values":["2009-12-01"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Applied Science (MASc)"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (MASc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Ontario Institute of Technology"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dynamic flowgraph methodology","Networked control system","Cu-Cl cycle","Instrumentation and control systems","Communication network"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10155/67"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The use of communication networks in digital control systems introduces stability and reliability concerns. Standard reliability and safety assessment methods need further modification to accommodate the issue in the reliability assessment of networked control systems. In this thesis, it is demonstrated that the Dynamic Flowgraph Methodology (DFM) can be extended to model networked control systems. The modelling of the communication network influence on the performance of the control system is presented. The areas that can affect the reliability of the control system are identified using the methodology. The thesis also presents the application of the DFM to a nuclear-based thermochemical water splitting process for hydrogen production, the Copper-Chlorine (Cu-Cl) cycle. The architecture of a networked control system and configuration of instrumentation and control systems for the hydrogen production plant are proposed in the thesis."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["University of Ontario Institute of Technology"]},{"key":"dc:title","label":"Title","values":["Dynamic flowgraph methodology for reliability modelling of networked control systems: with application to a nuclear-based hydrogen production plant"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Lu, Lixuan"],"dc:creator":["Al-Dabbagh, Ahmad Wail"],"dc:date.accessioned":["2010-02-12T19:42:17Z","2022-03-29T16:34:11Z"],"dc:date.available":["2010-02-12T19:42:17Z","2022-03-29T16:34:11Z"],"dc:date.issued":["2009-12-01"],"dc:description.abstract":["The use of communication networks in digital control systems introduces stability and reliability concerns. Standard reliability and safety assessment methods need further modification to accommodate the issue in the reliability assessment of networked control systems. In this thesis, it is demonstrated that the Dynamic Flowgraph Methodology (DFM) can be extended to model networked control systems. The modelling of the communication network influence on the performance of the control system is presented. The areas that can affect the reliability of the control system are identified using the methodology. The thesis also presents the application of the DFM to a nuclear-based thermochemical water splitting process for hydrogen production, the Copper-Chlorine (Cu-Cl) cycle. The architecture of a networked control system and configuration of instrumentation and control systems for the hydrogen production plant are proposed in the thesis."],"dc:description.sponsorship":["University of Ontario Institute of Technology"],"dc:identifier.uri":["https://hdl.handle.net/10155/67"],"dc:language.iso":["en"],"dc:subject":["Dynamic flowgraph methodology","Networked control system","Cu-Cl cycle","Instrumentation and control systems","Communication network"],"dc:title":["Dynamic flowgraph methodology for reliability modelling of networked control systems: with application to a nuclear-based hydrogen production plant"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Master of Applied Science (MASc)"],"thesis:degree_name":["Master of Applied Science (MASc)"],"thesis:institution_name":["University of Ontario Institute of Technology"]},"updated_at":"2026-11-19T09:02:19Z"}