{"id":{"repo_id":"uoit","oai_identifier":"oai:ontariotechu.scholaris.ca:10155/756"},"canonical_url":"https://search.ndltd.org/etd/uoit/oai:ontariotechu.scholaris.ca:10155/756","repository":{"repo_id":"uoit","name":"Ontario Institute of Technology","base_url":"https://ontariotechu.scholaris.ca/server/oai/request"},"display":{"title":"Mathematical methods for 2D-3D cardiac image registration","abstract":"We propose a mathematical formulation aimed at intensity-based slice-to-volume registration, aligning a cross-sectional slice of a 3D volume to a 2D image. The approach is flexible and can accommodate various regularization schemes, similarity measures, and optimizers. We evaluate the framework by registering 2D and 3D cardiac magnetic resonance (MR) images obtained in vivo, aimed at image-guided surgery applications that utilise real-time MR imaging as a visualization tool. Rigid-body and affine transformations are used to validate the parametric model. Target registration error (TRE), Jaccard, and Dice indices are used to evaluate the algorithm and demonstrate the accuracy of the registration scheme on both simulated and clinical data. Registration with the affine model appeared to be more robust than the rigid model in controlled registration experiments. By simply extending the rigid model to an affine model, alignment of the cardiac region generally improved, without the need for complex dissimilarity measures or regularizers.","abstract_html":"We propose a mathematical formulation aimed at intensity-based slice-to-volume registration, aligning a cross-sectional slice of a 3D volume to a 2D image. The approach is flexible and can accommodate various regularization schemes, similarity measures, and optimizers. We evaluate the framework by registering 2D and 3D cardiac magnetic resonance (MR) images obtained in vivo, aimed at image-guided surgery applications that utilise real-time MR imaging as a visualization tool. Rigid-body and affine transformations are used to validate the parametric model. Target registration error (TRE), Jaccard, and Dice indices are used to evaluate the algorithm and demonstrate the accuracy of the registration scheme on both simulated and clinical data. Registration with the affine model appeared to be more robust than the rigid model in controlled registration experiments. By simply extending the rigid model to an affine model, alignment of the cardiac region generally improved, without the need for complex dissimilarity measures or regularizers.","abstract_has_math":false,"creators":["Ma, Lok Wan Lorraine"],"institution":"University of Ontario Institute of Technology","degree_name":"Master of Science (MSc)","degree_level":"Master of Science (MSc)","degree_discipline":"Modelling and Computational Science","degree_department":null,"school":null,"contributors":[],"advisors":["Ebrahimi, Mehran"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-12-01","date_published":"2016-12-01","updated_at":"2026-11-19T09:02:25Z","subjects":["Image registration","Inverse problems","Slice-to-volume registration model","Cardiac MRI","2D to 3D alignment"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10155/756","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10155/756","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Auoit%3Aoai%3Aontariotechu.scholaris.ca%3A10155%2F756","prefix":"oai_dc"},"source_record":{"url":"https://ontariotechu.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aontariotechu.scholaris.ca%3A10155%2F756","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ebrahimi, Mehran"]},{"key":"dc:creator","label":"Author","values":["Ma, Lok Wan Lorraine"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-05-03T20:02:35Z","2022-03-29T17:39:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-05-03T20:02:35Z","2022-03-29T17:39:19Z"]},{"key":"dc:date.issued","label":"Date","values":["2016-12-01"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Modelling and Computational Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (MSc)"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Ontario Institute of Technology"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Image registration","Inverse problems","Slice-to-volume registration model","Cardiac MRI","2D to 3D alignment"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10155/756"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["We propose a mathematical formulation aimed at intensity-based slice-to-volume registration, aligning a cross-sectional slice of a 3D volume to a 2D image. The approach is flexible and can accommodate various regularization schemes, similarity measures, and optimizers. We evaluate the framework by registering 2D and 3D cardiac magnetic resonance (MR) images obtained in vivo, aimed at image-guided surgery applications that utilise real-time MR imaging as a visualization tool. Rigid-body and affine transformations are used to validate the parametric model. Target registration error (TRE), Jaccard, and Dice indices are used to evaluate the algorithm and demonstrate the accuracy of the registration scheme on both simulated and clinical data. Registration with the affine model appeared to be more robust than the rigid model in controlled registration experiments. By simply extending the rigid model to an affine model, alignment of the cardiac region generally improved, without the need for complex dissimilarity measures or regularizers."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["University of Ontario Institute of Technology"]},{"key":"dc:title","label":"Title","values":["Mathematical methods for 2D-3D cardiac image registration"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ebrahimi, Mehran"],"dc:creator":["Ma, Lok Wan Lorraine"],"dc:date.accessioned":["2017-05-03T20:02:35Z","2022-03-29T17:39:19Z"],"dc:date.available":["2017-05-03T20:02:35Z","2022-03-29T17:39:19Z"],"dc:date.issued":["2016-12-01"],"dc:description.abstract":["We propose a mathematical formulation aimed at intensity-based slice-to-volume registration, aligning a cross-sectional slice of a 3D volume to a 2D image. The approach is flexible and can accommodate various regularization schemes, similarity measures, and optimizers. We evaluate the framework by registering 2D and 3D cardiac magnetic resonance (MR) images obtained in vivo, aimed at image-guided surgery applications that utilise real-time MR imaging as a visualization tool. Rigid-body and affine transformations are used to validate the parametric model. Target registration error (TRE), Jaccard, and Dice indices are used to evaluate the algorithm and demonstrate the accuracy of the registration scheme on both simulated and clinical data. Registration with the affine model appeared to be more robust than the rigid model in controlled registration experiments. By simply extending the rigid model to an affine model, alignment of the cardiac region generally improved, without the need for complex dissimilarity measures or regularizers."],"dc:description.sponsorship":["University of Ontario Institute of Technology"],"dc:identifier.uri":["https://hdl.handle.net/10155/756"],"dc:language.iso":["en"],"dc:subject":["Image registration","Inverse problems","Slice-to-volume registration model","Cardiac MRI","2D to 3D alignment"],"dc:title":["Mathematical methods for 2D-3D cardiac image registration"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Modelling and Computational Science"],"thesis:degree_level":["Master of Science (MSc)"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Ontario Institute of Technology"]},"updated_at":"2026-11-19T09:02:25Z"}