{"id":{"repo_id":"uoit","oai_identifier":"oai:ontariotechu.scholaris.ca:10155/93"},"canonical_url":"https://search.ndltd.org/etd/uoit/oai:ontariotechu.scholaris.ca:10155/93","repository":{"repo_id":"uoit","name":"Ontario Institute of Technology","base_url":"https://ontariotechu.scholaris.ca/server/oai/request"},"display":{"title":"Enhancing geothermal heat pump systems with parametric performance analyses","abstract":"Parametric performance analyses and comparison of a basic geothermal heat pump, a heat pump cycle with motor cooling/refrigerant preheating, and a heat pump cycle utilizing an economizer with respect to first law is conducted through simulation. Changing compressor, pump, and motor efficiency, along with condenser pressure, evaporator pressure, degree of subcooling at the condenser exit and degree of superheating at the evaporator exit is investigated. Economizer arrangements yield the highest coefficient of performance and resilience to change in COP with variation in evaporator pressure, and degree of superheating and subcooling. The basic vapor compression and motor cooling/refrigerant preheating systems have the lowest COP throughout and greatest resilience to variation in compressor efficiency, motor efficiency and condenser pressure. Motor cooling/refrigerant preheating and economizers have advantages over basic vapor compression cycles. Motor cooling reduces ground loop heat exchanger length with similar COP, and economizers allow for an increase in COP compared to the basic cycle.","abstract_html":"Parametric performance analyses and comparison of a basic geothermal heat pump, a heat pump cycle with motor cooling/refrigerant preheating, and a heat pump cycle utilizing an economizer with respect to first law is conducted through simulation. Changing compressor, pump, and motor efficiency, along with condenser pressure, evaporator pressure, degree of subcooling at the condenser exit and degree of superheating at the evaporator exit is investigated. Economizer arrangements yield the highest coefficient of performance and resilience to change in COP with variation in evaporator pressure, and degree of superheating and subcooling. The basic vapor compression and motor cooling/refrigerant preheating systems have the lowest COP throughout and greatest resilience to variation in compressor efficiency, motor efficiency and condenser pressure. Motor cooling/refrigerant preheating and economizers have advantages over basic vapor compression cycles. Motor cooling reduces ground loop heat exchanger length with similar COP, and economizers allow for an increase in COP compared to the basic cycle.","abstract_has_math":false,"creators":["Self, Stuart"],"institution":"University of Ontario Institute of Technology","degree_name":"Master of Applied Science (MASc)","degree_level":"Master of Applied Science (MASc)","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Reddy, Bale V.","Rosen, Marc A."],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-04-01","date_published":"2010-04-01","updated_at":"2026-11-19T09:02:31Z","subjects":["Geothermal heat pump","Parametric performance analysis","Heat pump cycle","Superheating","Subcooling","Vapor compression"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10155/93","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10155/93","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Auoit%3Aoai%3Aontariotechu.scholaris.ca%3A10155%2F93","prefix":"oai_dc"},"source_record":{"url":"https://ontariotechu.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aontariotechu.scholaris.ca%3A10155%2F93","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Reddy, Bale V.","Rosen, Marc A."]},{"key":"dc:creator","label":"Author","values":["Self, Stuart"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-06-04T19:59:40Z","2022-03-29T14:52:48Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-06-04T19:59:40Z","2022-03-29T14:52:48Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-04-01"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Applied Science (MASc)"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (MASc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Ontario Institute of Technology"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Geothermal heat pump","Parametric performance analysis","Heat pump cycle","Superheating","Subcooling","Vapor compression"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10155/93"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Parametric performance analyses and comparison of a basic geothermal heat pump, a heat pump cycle with motor cooling/refrigerant preheating, and a heat pump cycle utilizing an economizer with respect to first law is conducted through simulation. Changing compressor, pump, and motor efficiency, along with condenser pressure, evaporator pressure, degree of subcooling at the condenser exit and degree of superheating at the evaporator exit is investigated. Economizer arrangements yield the highest coefficient of performance and resilience to change in COP with variation in evaporator pressure, and degree of superheating and subcooling. The basic vapor compression and motor cooling/refrigerant preheating systems have the lowest COP throughout and greatest resilience to variation in compressor efficiency, motor efficiency and condenser pressure. Motor cooling/refrigerant preheating and economizers have advantages over basic vapor compression cycles. Motor cooling reduces ground loop heat exchanger length with similar COP, and economizers allow for an increase in COP compared to the basic cycle."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["University of Ontario Institute of Technology"]},{"key":"dc:title","label":"Title","values":["Enhancing geothermal heat pump systems with parametric performance analyses"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Reddy, Bale V.","Rosen, Marc A."],"dc:creator":["Self, Stuart"],"dc:date.accessioned":["2010-06-04T19:59:40Z","2022-03-29T14:52:48Z"],"dc:date.available":["2010-06-04T19:59:40Z","2022-03-29T14:52:48Z"],"dc:date.issued":["2010-04-01"],"dc:description.abstract":["Parametric performance analyses and comparison of a basic geothermal heat pump, a heat pump cycle with motor cooling/refrigerant preheating, and a heat pump cycle utilizing an economizer with respect to first law is conducted through simulation. Changing compressor, pump, and motor efficiency, along with condenser pressure, evaporator pressure, degree of subcooling at the condenser exit and degree of superheating at the evaporator exit is investigated. Economizer arrangements yield the highest coefficient of performance and resilience to change in COP with variation in evaporator pressure, and degree of superheating and subcooling. The basic vapor compression and motor cooling/refrigerant preheating systems have the lowest COP throughout and greatest resilience to variation in compressor efficiency, motor efficiency and condenser pressure. Motor cooling/refrigerant preheating and economizers have advantages over basic vapor compression cycles. Motor cooling reduces ground loop heat exchanger length with similar COP, and economizers allow for an increase in COP compared to the basic cycle."],"dc:description.sponsorship":["University of Ontario Institute of Technology"],"dc:identifier.uri":["https://hdl.handle.net/10155/93"],"dc:language.iso":["en"],"dc:subject":["Geothermal heat pump","Parametric performance analysis","Heat pump cycle","Superheating","Subcooling","Vapor compression"],"dc:title":["Enhancing geothermal heat pump systems with parametric performance analyses"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Master of Applied Science (MASc)"],"thesis:degree_name":["Master of Applied Science (MASc)"],"thesis:institution_name":["University of Ontario Institute of Technology"]},"updated_at":"2026-11-19T09:02:31Z"}