{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-10254"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-10254","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"Influence of Coating Defects Within the Lock Seams on the Corrosion Performance of Aluminized Steel Drainage Pipes","abstract":"The electrochemical behavior of aluminized steel is investigated to determine the corrosion performance of coating deficiencies generated within the lock seams during the fabrication of aluminized steel corrugated pipe. Electrochemical techniques and visual and profilometric analysis are used to assess the ability of the aluminum and zinc coating to provide sufficient galvanic protection to the underlying steel in the presence of a crevice. Also, Crevice coupons and lock-seam samples were used in this investigation in different environmental conditions simulating natural water conditions to relate the corrosion rate with the level of protection that the coating will provide. In addition, a model was developed to identify the influence of the confined geometry of the lock seam on the corrosion rates at a defect location. The results have shown that defects in the aluminum coating can act as initiation sites for the corrosion of the steel. However, defects located external to the lock seam may corrode at higher rates than those within the lock seams due to the limited availability of oxygen.","abstract_html":"The electrochemical behavior of aluminized steel is investigated to determine the corrosion performance of coating deficiencies generated within the lock seams during the fabrication of aluminized steel corrugated pipe. Electrochemical techniques and visual and profilometric analysis are used to assess the ability of the aluminum and zinc coating to provide sufficient galvanic protection to the underlying steel in the presence of a crevice. Also, Crevice coupons and lock-seam samples were used in this investigation in different environmental conditions simulating natural water conditions to relate the corrosion rate with the level of protection that the coating will provide. In addition, a model was developed to identify the influence of the confined geometry of the lock seam on the corrosion rates at a defect location. The results have shown that defects in the aluminum coating can act as initiation sites for the corrosion of the steel. However, defects located external to the lock seam may corrode at higher rates than those within the lock seams due to the limited availability of oxygen.","abstract_has_math":false,"creators":["Al Yaarubi, Mohammed"],"institution":"University of South Florida","degree_name":"MS in Civil Engineering (M.S.C.E.)","degree_level":"Thesis","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Christopher L. Alexander, Ph.D.","Alberto A. Sagüés, Ph.D.","Michael Cai Wang, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-06-25T07:00:00Z","date_published":"2021-06-25T07:00:00Z","updated_at":"2026-11-19T08:47:28Z","subjects":["Cut Edge","SVET","Chloride","Crevice Corrosion","Civil Engineering","Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/9057","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/9057","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-10254","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Christopher L. Alexander, Ph.D.","Alberto A. Sagüés, Ph.D.","Michael Cai Wang, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Al Yaarubi, Mohammed"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-06-25T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.S.C.E."]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Civil Engineering (M.S.C.E.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Cut Edge","SVET","Chloride","Crevice Corrosion","Civil Engineering","Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/9057"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The electrochemical behavior of aluminized steel is investigated to determine the corrosion performance of coating deficiencies generated within the lock seams during the fabrication of aluminized steel corrugated pipe. Electrochemical techniques and visual and profilometric analysis are used to assess the ability of the aluminum and zinc coating to provide sufficient galvanic protection to the underlying steel in the presence of a crevice. Also, Crevice coupons and lock-seam samples were used in this investigation in different environmental conditions simulating natural water conditions to relate the corrosion rate with the level of protection that the coating will provide. In addition, a model was developed to identify the influence of the confined geometry of the lock seam on the corrosion rates at a defect location. The results have shown that defects in the aluminum coating can act as initiation sites for the corrosion of the steel. However, defects located external to the lock seam may corrode at higher rates than those within the lock seams due to the limited availability of oxygen."]},{"key":"dc:title","label":"Title","values":["Influence of Coating Defects Within the Lock Seams on the Corrosion Performance of Aluminized Steel Drainage Pipes"]}]}],"canonical_facts":{"dc:contributor":["Christopher L. Alexander, Ph.D.","Alberto A. Sagüés, Ph.D.","Michael Cai Wang, Ph.D."],"dc:creator":["Al Yaarubi, Mohammed"],"dc:date":["2021-06-25T07:00:00Z"],"dc:description":["The electrochemical behavior of aluminized steel is investigated to determine the corrosion performance of coating deficiencies generated within the lock seams during the fabrication of aluminized steel corrugated pipe. Electrochemical techniques and visual and profilometric analysis are used to assess the ability of the aluminum and zinc coating to provide sufficient galvanic protection to the underlying steel in the presence of a crevice. Also, Crevice coupons and lock-seam samples were used in this investigation in different environmental conditions simulating natural water conditions to relate the corrosion rate with the level of protection that the coating will provide. In addition, a model was developed to identify the influence of the confined geometry of the lock seam on the corrosion rates at a defect location. The results have shown that defects in the aluminum coating can act as initiation sites for the corrosion of the steel. However, defects located external to the lock seam may corrode at higher rates than those within the lock seams due to the limited availability of oxygen."],"dc:identifier":["https://digitalcommons.usf.edu/etd/9057"],"dc:subject":["Cut Edge","SVET","Chloride","Crevice Corrosion","Civil Engineering","Engineering"],"dc:title":["Influence of Coating Defects Within the Lock Seams on the Corrosion Performance of Aluminized Steel Drainage Pipes"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis","M.S.C.E."],"thesis:degree_name":["MS in Civil Engineering (M.S.C.E.)"],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:47:28Z"}