{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-10511"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-10511","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"Evaluation of Aluminum Dissolution, Current Density, and Pitting Patterns During Electrocoagulation","abstract":"Electrocoagulation (EC) is a sustainable water treatment process involving the generation of coagulants on-site through the application of a voltage on metal (usually aluminum or iron alloys). The factors that impact EC system performance have been well researched, however further research is needed on the factors that impact anodic dissolution of aluminum electrodes, especially when the technology is transferred to full-scale applications. Electrode fouling is one of the factors that can impact dissolution of the anode during EC due to the formation of a protective oxide/hydroxide layer on the electrode surface. Previous studies have addressed electrode fouling by reversing polarity, however results have been mixed or obtained for shorter timeframes that might not be applicable to full-scale EC systems. In addition, discussion regarding pitting patterns and aluminum production during EC water treatment is limited. In this study, the effect of switching polarity and pitting patterns (pit size, type, and location) on aluminum production and current density were evaluated in a continuously mixed EC batch reactor. The corrosion timeline and the effect of switching polarity versus normal operation on pitting trends over the expected life of the aluminum plates were also evaluated. The results showed that system performance was superior over time when direct polarity was used, due to sustained higher aluminum production and correlation between aluminum and current. Therefore, the use of direct polarity was recommended over the use of reverse polarity within the experimental parameters implemented.","abstract_html":"Electrocoagulation (EC) is a sustainable water treatment process involving the generation of coagulants on-site through the application of a voltage on metal (usually aluminum or iron alloys). The factors that impact EC system performance have been well researched, however further research is needed on the factors that impact anodic dissolution of aluminum electrodes, especially when the technology is transferred to full-scale applications. Electrode fouling is one of the factors that can impact dissolution of the anode during EC due to the formation of a protective oxide/hydroxide layer on the electrode surface. Previous studies have addressed electrode fouling by reversing polarity, however results have been mixed or obtained for shorter timeframes that might not be applicable to full-scale EC systems. In addition, discussion regarding pitting patterns and aluminum production during EC water treatment is limited. In this study, the effect of switching polarity and pitting patterns (pit size, type, and location) on aluminum production and current density were evaluated in a continuously mixed EC batch reactor. The corrosion timeline and the effect of switching polarity versus normal operation on pitting trends over the expected life of the aluminum plates were also evaluated. The results showed that system performance was superior over time when direct polarity was used, due to sustained higher aluminum production and correlation between aluminum and current. Therefore, the use of direct polarity was recommended over the use of reverse polarity within the experimental parameters implemented.","abstract_has_math":false,"creators":["Castro Carias, Monica"],"institution":"University of South Florida","degree_name":"MS in Environmental Engr. (M.S.E.V.)","degree_level":"Thesis","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Katherine Alfredo, Ph.D.","Christopher Alexander, Ph.D.","Qiong Zhang, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-06-24T07:00:00Z","date_published":"2022-06-24T07:00:00Z","updated_at":"2026-11-19T08:47:41Z","subjects":["drinking water","electrode fouling","electrolysis","pitting","potentiostatic","Chemical Engineering","Civil Engineering","Environmental Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/9314","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/9314","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-10511","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Katherine Alfredo, Ph.D.","Christopher Alexander, Ph.D.","Qiong Zhang, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Castro Carias, Monica"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-06-24T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.S.E.V."]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Environmental Engr. (M.S.E.V.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["drinking water","electrode fouling","electrolysis","pitting","potentiostatic","Chemical Engineering","Civil Engineering","Environmental Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/9314"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Electrocoagulation (EC) is a sustainable water treatment process involving the generation of coagulants on-site through the application of a voltage on metal (usually aluminum or iron alloys). The factors that impact EC system performance have been well researched, however further research is needed on the factors that impact anodic dissolution of aluminum electrodes, especially when the technology is transferred to full-scale applications. Electrode fouling is one of the factors that can impact dissolution of the anode during EC due to the formation of a protective oxide/hydroxide layer on the electrode surface. Previous studies have addressed electrode fouling by reversing polarity, however results have been mixed or obtained for shorter timeframes that might not be applicable to full-scale EC systems. In addition, discussion regarding pitting patterns and aluminum production during EC water treatment is limited. In this study, the effect of switching polarity and pitting patterns (pit size, type, and location) on aluminum production and current density were evaluated in a continuously mixed EC batch reactor. The corrosion timeline and the effect of switching polarity versus normal operation on pitting trends over the expected life of the aluminum plates were also evaluated. The results showed that system performance was superior over time when direct polarity was used, due to sustained higher aluminum production and correlation between aluminum and current. Therefore, the use of direct polarity was recommended over the use of reverse polarity within the experimental parameters implemented."]},{"key":"dc:title","label":"Title","values":["Evaluation of Aluminum Dissolution, Current Density, and Pitting Patterns During Electrocoagulation"]}]}],"canonical_facts":{"dc:contributor":["Katherine Alfredo, Ph.D.","Christopher Alexander, Ph.D.","Qiong Zhang, Ph.D."],"dc:creator":["Castro Carias, Monica"],"dc:date":["2022-06-24T07:00:00Z"],"dc:description":["Electrocoagulation (EC) is a sustainable water treatment process involving the generation of coagulants on-site through the application of a voltage on metal (usually aluminum or iron alloys). The factors that impact EC system performance have been well researched, however further research is needed on the factors that impact anodic dissolution of aluminum electrodes, especially when the technology is transferred to full-scale applications. Electrode fouling is one of the factors that can impact dissolution of the anode during EC due to the formation of a protective oxide/hydroxide layer on the electrode surface. Previous studies have addressed electrode fouling by reversing polarity, however results have been mixed or obtained for shorter timeframes that might not be applicable to full-scale EC systems. In addition, discussion regarding pitting patterns and aluminum production during EC water treatment is limited. In this study, the effect of switching polarity and pitting patterns (pit size, type, and location) on aluminum production and current density were evaluated in a continuously mixed EC batch reactor. The corrosion timeline and the effect of switching polarity versus normal operation on pitting trends over the expected life of the aluminum plates were also evaluated. The results showed that system performance was superior over time when direct polarity was used, due to sustained higher aluminum production and correlation between aluminum and current. Therefore, the use of direct polarity was recommended over the use of reverse polarity within the experimental parameters implemented."],"dc:identifier":["https://digitalcommons.usf.edu/etd/9314"],"dc:subject":["drinking water","electrode fouling","electrolysis","pitting","potentiostatic","Chemical Engineering","Civil Engineering","Environmental Engineering"],"dc:title":["Evaluation of Aluminum Dissolution, Current Density, and Pitting Patterns During Electrocoagulation"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis","M.S.E.V."],"thesis:degree_name":["MS in Environmental Engr. (M.S.E.V.)"],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:47:41Z"}