{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-11037"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-11037","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"The Influence of Corrosion Mitigating Fluids on Post Tensioned Tendon Grout Properties and Steel to Grout Bond Strength","abstract":"Corrosion has been a persistent problem causing the failure of post-tensioned tendons in segmentally constructed bridges. To address this issue, the impregnation method has been considered where the corrosion-mitigating fluids are pressure injected into the interstitial spaces between the seven wires of steel strands. A previous study showed that this method was able to arrest corrosion. However, it compromised the bond strength between the steel and the strand. For that reason, this study aims to identify a fluid that can be impregnated into the interstitial spaces without sacrificing bond performance. The most promising fluid found in the study is an inhibiting fluid traditionally used as coatings on reinforcing bars, which had minimal impact on grout properties. Ongoing research will determine whether it effectively mitigates corrosion.","abstract_html":"Corrosion has been a persistent problem causing the failure of post-tensioned tendons in segmentally constructed bridges. To address this issue, the impregnation method has been considered where the corrosion-mitigating fluids are pressure injected into the interstitial spaces between the seven wires of steel strands. A previous study showed that this method was able to arrest corrosion. However, it compromised the bond strength between the steel and the strand. For that reason, this study aims to identify a fluid that can be impregnated into the interstitial spaces without sacrificing bond performance. The most promising fluid found in the study is an inhibiting fluid traditionally used as coatings on reinforcing bars, which had minimal impact on grout properties. Ongoing research will determine whether it effectively mitigates corrosion.","abstract_has_math":false,"creators":["Ale Magar, Sarita"],"institution":"University of South Florida","degree_name":"MS in Civil Engineering (M.S.C.E.)","degree_level":"Thesis","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Christopher Alexander, Ph.D.","Gray Mullins, Ph.D.","Zachary B. Haber, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-03-13T07:00:00Z","date_published":"2023-03-13T07:00:00Z","updated_at":"2026-11-19T08:48:44Z","subjects":["Prestressed Concrete","Bonded Tendons","Bond Performance","Compressive Strength","Civil Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/9840","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/9840","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-11037","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Christopher Alexander, Ph.D.","Gray Mullins, Ph.D.","Zachary B. Haber, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Ale Magar, Sarita"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-03-13T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.S.C.E."]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Civil Engineering (M.S.C.E.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Prestressed Concrete","Bonded Tendons","Bond Performance","Compressive Strength","Civil Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/9840"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Corrosion has been a persistent problem causing the failure of post-tensioned tendons in segmentally constructed bridges. To address this issue, the impregnation method has been considered where the corrosion-mitigating fluids are pressure injected into the interstitial spaces between the seven wires of steel strands. A previous study showed that this method was able to arrest corrosion. However, it compromised the bond strength between the steel and the strand. For that reason, this study aims to identify a fluid that can be impregnated into the interstitial spaces without sacrificing bond performance. The most promising fluid found in the study is an inhibiting fluid traditionally used as coatings on reinforcing bars, which had minimal impact on grout properties. Ongoing research will determine whether it effectively mitigates corrosion."]},{"key":"dc:title","label":"Title","values":["The Influence of Corrosion Mitigating Fluids on Post Tensioned Tendon Grout Properties and Steel to Grout Bond Strength"]}]}],"canonical_facts":{"dc:contributor":["Christopher Alexander, Ph.D.","Gray Mullins, Ph.D.","Zachary B. Haber, Ph.D."],"dc:creator":["Ale Magar, Sarita"],"dc:date":["2023-03-13T07:00:00Z"],"dc:description":["Corrosion has been a persistent problem causing the failure of post-tensioned tendons in segmentally constructed bridges. To address this issue, the impregnation method has been considered where the corrosion-mitigating fluids are pressure injected into the interstitial spaces between the seven wires of steel strands. A previous study showed that this method was able to arrest corrosion. However, it compromised the bond strength between the steel and the strand. For that reason, this study aims to identify a fluid that can be impregnated into the interstitial spaces without sacrificing bond performance. The most promising fluid found in the study is an inhibiting fluid traditionally used as coatings on reinforcing bars, which had minimal impact on grout properties. Ongoing research will determine whether it effectively mitigates corrosion."],"dc:identifier":["https://digitalcommons.usf.edu/etd/9840"],"dc:subject":["Prestressed Concrete","Bonded Tendons","Bond Performance","Compressive Strength","Civil Engineering"],"dc:title":["The Influence of Corrosion Mitigating Fluids on Post Tensioned Tendon Grout Properties and Steel to Grout Bond Strength"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis","M.S.C.E."],"thesis:degree_name":["MS in Civil Engineering (M.S.C.E.)"],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:48:44Z"}