{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-11736"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-11736","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"Remote Medical Diagnosis via Infrared Thermography and Augmented Reality","abstract":"Fast, accurate, and non-invasive diagnostic techniques are required by the medical industry to increase the success of medical treatments and enhance the quality of patient care. Medical IRT has been demonstrated reasonably effective at diagnosing and monitoring several physiological conditions. Diversities in the human body, physical and psychological condition, measurement equipment, and environment all influence the sensitive readings obtained by passive IR measurement devices. New standards for medical IRT and fever screening have been demonstrated effective, but there is limited adherence to the guidelines [36]. Absolute temperature readings require regular calibration checks and can easily be thrown off by noise. Finally, limited IRT images and data are available for training ML and DL models, and annotating the images manually is time consuming. New methods are required to annotate medical IRT images and evaluate them for diagnostic potential. Multiple vital signs are required for making more accurate assessments of Upper Respiratory Tract Infections. An AR app is created to provide remote measurement of vital signs and detect contagious diseases in real-time.","abstract_html":"Fast, accurate, and non-invasive diagnostic techniques are required by the medical industry to increase the success of medical treatments and enhance the quality of patient care. Medical IRT has been demonstrated reasonably effective at diagnosing and monitoring several physiological conditions. Diversities in the human body, physical and psychological condition, measurement equipment, and environment all influence the sensitive readings obtained by passive IR measurement devices. New standards for medical IRT and fever screening have been demonstrated effective, but there is limited adherence to the guidelines [36]. Absolute temperature readings require regular calibration checks and can easily be thrown off by noise. Finally, limited IRT images and data are available for training ML and DL models, and annotating the images manually is time consuming. New methods are required to annotate medical IRT images and evaluate them for diagnostic potential. Multiple vital signs are required for making more accurate assessments of Upper Respiratory Tract Infections. An AR app is created to provide remote measurement of vital signs and detect contagious diseases in real-time.","abstract_has_math":false,"creators":["Selkey, Frederick M."],"institution":"University of South Florida","degree_name":"MS in Electrical Engineering (M.S.E.E.)","degree_level":"Thesis","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["Stephen Saddow, Ph.D.","Mark Jaroszeski, Ph.D.","Sriram Chellappan, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-03-15T07:00:00Z","date_published":"2023-03-15T07:00:00Z","updated_at":"2026-11-19T08:50:05Z","subjects":["Contagious","Kiosk","Mobile","Scanner","Upper Respiratory Tract Infection","Biomedical Engineering and Bioengineering","Computer Sciences","Electrical and Computer Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/10449","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/10449","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-11736","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Stephen Saddow, Ph.D.","Mark Jaroszeski, Ph.D.","Sriram Chellappan, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Selkey, Frederick M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-03-15T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.S.E.E."]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Electrical Engineering (M.S.E.E.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Contagious","Kiosk","Mobile","Scanner","Upper Respiratory Tract Infection","Biomedical Engineering and Bioengineering","Computer Sciences","Electrical and Computer Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/10449"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Fast, accurate, and non-invasive diagnostic techniques are required by the medical industry to increase the success of medical treatments and enhance the quality of patient care. Medical IRT has been demonstrated reasonably effective at diagnosing and monitoring several physiological conditions. Diversities in the human body, physical and psychological condition, measurement equipment, and environment all influence the sensitive readings obtained by passive IR measurement devices. New standards for medical IRT and fever screening have been demonstrated effective, but there is limited adherence to the guidelines [36]. Absolute temperature readings require regular calibration checks and can easily be thrown off by noise. Finally, limited IRT images and data are available for training ML and DL models, and annotating the images manually is time consuming. New methods are required to annotate medical IRT images and evaluate them for diagnostic potential. Multiple vital signs are required for making more accurate assessments of Upper Respiratory Tract Infections. An AR app is created to provide remote measurement of vital signs and detect contagious diseases in real-time."]},{"key":"dc:title","label":"Title","values":["Remote Medical Diagnosis via Infrared Thermography and Augmented Reality"]}]}],"canonical_facts":{"dc:contributor":["Stephen Saddow, Ph.D.","Mark Jaroszeski, Ph.D.","Sriram Chellappan, Ph.D."],"dc:creator":["Selkey, Frederick M."],"dc:date":["2023-03-15T07:00:00Z"],"dc:description":["Fast, accurate, and non-invasive diagnostic techniques are required by the medical industry to increase the success of medical treatments and enhance the quality of patient care. Medical IRT has been demonstrated reasonably effective at diagnosing and monitoring several physiological conditions. Diversities in the human body, physical and psychological condition, measurement equipment, and environment all influence the sensitive readings obtained by passive IR measurement devices. New standards for medical IRT and fever screening have been demonstrated effective, but there is limited adherence to the guidelines [36]. Absolute temperature readings require regular calibration checks and can easily be thrown off by noise. Finally, limited IRT images and data are available for training ML and DL models, and annotating the images manually is time consuming. New methods are required to annotate medical IRT images and evaluate them for diagnostic potential. Multiple vital signs are required for making more accurate assessments of Upper Respiratory Tract Infections. An AR app is created to provide remote measurement of vital signs and detect contagious diseases in real-time."],"dc:identifier":["https://digitalcommons.usf.edu/etd/10449"],"dc:subject":["Contagious","Kiosk","Mobile","Scanner","Upper Respiratory Tract Infection","Biomedical Engineering and Bioengineering","Computer Sciences","Electrical and Computer Engineering"],"dc:title":["Remote Medical Diagnosis via Infrared Thermography and Augmented Reality"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Thesis","M.S.E.E."],"thesis:degree_name":["MS in Electrical Engineering (M.S.E.E.)"],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:50:05Z"}