{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-12322"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-12322","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"Wireless In-Situ Slurry Testing Device","abstract":"Deep foundations are a critical piece of infrastructure used in bridge and high-rise constructions. A type of deep foundation called a drilled shaft is commonly used for these types of large structures due to their ability to resist large axial and lateral loads. Excavations in many soils require hole stabilization methods often involving drilling fluids like polymer or bentonite slurries. When used properly, these slurries prevent groundwater intrusion and side wall sloughing into the excavation. Slurry specifications are set by local or state jurisdictions, research findings, or product manufacturers. Over the years, the Florida standard specifications on slurry integrity testing have been changed to allow testing on larger intervals, decreasing the amount of testing done. The current field-testing methods for slurry properties require removing a sample of slurry from the excavation and testing per standardized testing procedures. Removing and testing samples is time consuming and has led to the development of downhole devices to measure slurry properties in-place. The basis of this research was to improve upon a previously designed downhole slurry device. While this new device uses the same concepts as the previous device, the intent was to make it more compact, digital, wireless, and user-friendly. The modernization of the major components of the device contributed heavily to the new device weight and size, making it far easier to lower and remove the device from drilled shaft excavations. An on-board computer incorporates a data acquisition system which provides Bluetooth communications and data transfer.","abstract_html":"Deep foundations are a critical piece of infrastructure used in bridge and high-rise constructions. A type of deep foundation called a drilled shaft is commonly used for these types of large structures due to their ability to resist large axial and lateral loads. Excavations in many soils require hole stabilization methods often involving drilling fluids like polymer or bentonite slurries. When used properly, these slurries prevent groundwater intrusion and side wall sloughing into the excavation. Slurry specifications are set by local or state jurisdictions, research findings, or product manufacturers. Over the years, the Florida standard specifications on slurry integrity testing have been changed to allow testing on larger intervals, decreasing the amount of testing done. The current field-testing methods for slurry properties require removing a sample of slurry from the excavation and testing per standardized testing procedures. Removing and testing samples is time consuming and has led to the development of downhole devices to measure slurry properties in-place. The basis of this research was to improve upon a previously designed downhole slurry device. While this new device uses the same concepts as the previous device, the intent was to make it more compact, digital, wireless, and user-friendly. The modernization of the major components of the device contributed heavily to the new device weight and size, making it far easier to lower and remove the device from drilled shaft excavations. An on-board computer incorporates a data acquisition system which provides Bluetooth communications and data transfer.","abstract_has_math":false,"creators":["Ward, Andrew"],"institution":"University of South Florida","degree_name":"MS in Civil Engineering (M.S.C.E.)","degree_level":"Thesis","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Gray Mullins, Ph.D.","Tristen Mee, Ph.D.","Michael J. Stokes, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-06-16T07:00:00Z","date_published":"2025-06-16T07:00:00Z","updated_at":"2026-11-19T08:49:40Z","subjects":["Density","Drilled Shafts","Drilling Fluids","Sand Content","Viscosity","Civil Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/11019","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/11019","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-12322","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Gray Mullins, Ph.D.","Tristen Mee, Ph.D.","Michael J. Stokes, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Ward, Andrew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-06-16T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.S.C.E."]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Civil Engineering (M.S.C.E.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Density","Drilled Shafts","Drilling Fluids","Sand Content","Viscosity","Civil Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/11019"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Deep foundations are a critical piece of infrastructure used in bridge and high-rise constructions. A type of deep foundation called a drilled shaft is commonly used for these types of large structures due to their ability to resist large axial and lateral loads. Excavations in many soils require hole stabilization methods often involving drilling fluids like polymer or bentonite slurries. When used properly, these slurries prevent groundwater intrusion and side wall sloughing into the excavation. Slurry specifications are set by local or state jurisdictions, research findings, or product manufacturers. Over the years, the Florida standard specifications on slurry integrity testing have been changed to allow testing on larger intervals, decreasing the amount of testing done. The current field-testing methods for slurry properties require removing a sample of slurry from the excavation and testing per standardized testing procedures. Removing and testing samples is time consuming and has led to the development of downhole devices to measure slurry properties in-place. The basis of this research was to improve upon a previously designed downhole slurry device. While this new device uses the same concepts as the previous device, the intent was to make it more compact, digital, wireless, and user-friendly. The modernization of the major components of the device contributed heavily to the new device weight and size, making it far easier to lower and remove the device from drilled shaft excavations. An on-board computer incorporates a data acquisition system which provides Bluetooth communications and data transfer."]},{"key":"dc:title","label":"Title","values":["Wireless In-Situ Slurry Testing Device"]}]}],"canonical_facts":{"dc:contributor":["Gray Mullins, Ph.D.","Tristen Mee, Ph.D.","Michael J. Stokes, Ph.D."],"dc:creator":["Ward, Andrew"],"dc:date":["2025-06-16T07:00:00Z"],"dc:description":["Deep foundations are a critical piece of infrastructure used in bridge and high-rise constructions. A type of deep foundation called a drilled shaft is commonly used for these types of large structures due to their ability to resist large axial and lateral loads. Excavations in many soils require hole stabilization methods often involving drilling fluids like polymer or bentonite slurries. When used properly, these slurries prevent groundwater intrusion and side wall sloughing into the excavation. Slurry specifications are set by local or state jurisdictions, research findings, or product manufacturers. Over the years, the Florida standard specifications on slurry integrity testing have been changed to allow testing on larger intervals, decreasing the amount of testing done. The current field-testing methods for slurry properties require removing a sample of slurry from the excavation and testing per standardized testing procedures. Removing and testing samples is time consuming and has led to the development of downhole devices to measure slurry properties in-place. The basis of this research was to improve upon a previously designed downhole slurry device. While this new device uses the same concepts as the previous device, the intent was to make it more compact, digital, wireless, and user-friendly. The modernization of the major components of the device contributed heavily to the new device weight and size, making it far easier to lower and remove the device from drilled shaft excavations. An on-board computer incorporates a data acquisition system which provides Bluetooth communications and data transfer."],"dc:identifier":["https://digitalcommons.usf.edu/etd/11019"],"dc:subject":["Density","Drilled Shafts","Drilling Fluids","Sand Content","Viscosity","Civil Engineering"],"dc:title":["Wireless In-Situ Slurry Testing Device"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis","M.S.C.E."],"thesis:degree_name":["MS in Civil Engineering (M.S.C.E.)"],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:49:40Z"}