{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-12342"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-12342","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"Graphene Screen-Printed Electrode for Wound-Related Biosensing","abstract":"Monitoring wound healing is critical for improving patient outcomes, especially for chronic wounds, which often have complications like delayed healing and infections. Current methods for monitoring wound healing are invasive and costly. Also, these methods have a limited ability to provide real-time, continuous data. This study seeks to explore a graphene screen-printed electrode (SPE) electrochemical biosensor that is non-invasive and efficient to constantly monitor wound healing in real time. This research study focuses specifically on the electrochemical detection of the Human Neutrophil Elastase (HNE) and Secretory Leukocyte Protease Inhibitor (SLPI), which is one of the most abundant neutral proteinases in chronic wounds. Studies have found that Human Neutrophil Elastase (HNE) activity is elevated in chronic wounds, while diminished in healing wounds. Investigating the electrochemical responses of Human Neutrophil Elastase (HNE) and Secretory Leukocyte Protease Inhibitor (SLPI) could lead to a possible marker regarding severe wound inflammation or infection.In this study, two different conductive polymer-based graphene inks were prepared: PEDOT:PSS and polyaniline (PANI). Cyclic voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS) testing showed that the PANI-based ink was more conductive than the PEDOT:PSS. Thus, graphene PANI ink is a preferred choice regarding further sensor development. An optimized volume of PANI-graphene ink was established to achieve surface stability and ensure good conductivity. The electrode surface was functionalized using EDC/NHS chemistry to enable biomolecule immobilization. The sensors were tested at different HNE and SLPI antigen concentrations to determine the sensors' sensitivity, selectivity, and dynamic range of detection. The results have shown that the impedance response increased with HNE and SLPI concentration, confirming antigen binding and verifying the sensor’s good sensitivity with a wide detection range. LOD were calculated at 0.76 ng/mL for HNE detection and 0.37 ng/mL for SLPI detection. The reproducibility results yielded an RSD of approximately 3.3% across three sensors. This work seeks to develop an electrochemical platform that is reliable and reproducible for detecting HNE and SLPI as a wound biomarker. PANI-graphene ink offers a combination of both conductivity and stability. This combination shows its potential for point-of-care wound monitoring applications.","abstract_html":"Monitoring wound healing is critical for improving patient outcomes, especially for chronic wounds, which often have complications like delayed healing and infections. Current methods for monitoring wound healing are invasive and costly. Also, these methods have a limited ability to provide real-time, continuous data. This study seeks to explore a graphene screen-printed electrode (SPE) electrochemical biosensor that is non-invasive and efficient to constantly monitor wound healing in real time. This research study focuses specifically on the electrochemical detection of the Human Neutrophil Elastase (HNE) and Secretory Leukocyte Protease Inhibitor (SLPI), which is one of the most abundant neutral proteinases in chronic wounds. Studies have found that Human Neutrophil Elastase (HNE) activity is elevated in chronic wounds, while diminished in healing wounds. Investigating the electrochemical responses of Human Neutrophil Elastase (HNE) and Secretory Leukocyte Protease Inhibitor (SLPI) could lead to a possible marker regarding severe wound inflammation or infection.In this study, two different conductive polymer-based graphene inks were prepared: PEDOT:PSS and polyaniline (PANI). Cyclic voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS) testing showed that the PANI-based ink was more conductive than the PEDOT:PSS. Thus, graphene PANI ink is a preferred choice regarding further sensor development. An optimized volume of PANI-graphene ink was established to achieve surface stability and ensure good conductivity. The electrode surface was functionalized using EDC/NHS chemistry to enable biomolecule immobilization. The sensors were tested at different HNE and SLPI antigen concentrations to determine the sensors&#x27; sensitivity, selectivity, and dynamic range of detection. The results have shown that the impedance response increased with HNE and SLPI concentration, confirming antigen binding and verifying the sensor’s good sensitivity with a wide detection range. LOD were calculated at 0.76 ng/mL for HNE detection and 0.37 ng/mL for SLPI detection. The reproducibility results yielded an RSD of approximately 3.3% across three sensors. This work seeks to develop an electrochemical platform that is reliable and reproducible for detecting HNE and SLPI as a wound biomarker. PANI-graphene ink offers a combination of both conductivity and stability. This combination shows its potential for point-of-care wound monitoring applications.","abstract_has_math":false,"creators":["Sriviroch, Chanyapat"],"institution":"University of South Florida","degree_name":"MS in Mechanical Engineering (M.S.M.E.)","degree_level":"Thesis","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Ali Ashraf, Ph.D.","Ashok Kumar, Ph.D.","Wilfrido Moreno, Ph.D.","Piyush Koria, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-10-23T07:00:00Z","date_published":"2025-10-23T07:00:00Z","updated_at":"2026-11-19T08:49:16Z","subjects":["Biomarker Detection","Electrochemical Analysis","Nanomaterials","Point-of-Care Diagnostics","Polyaniline Modification","Engineering","Mechanical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/11039","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/11039","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-12342","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Ali Ashraf, Ph.D.","Ashok Kumar, Ph.D.","Wilfrido Moreno, Ph.D.","Piyush Koria, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Sriviroch, Chanyapat"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-10-23T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.S.M.E."]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Mechanical Engineering (M.S.M.E.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomarker Detection","Electrochemical Analysis","Nanomaterials","Point-of-Care Diagnostics","Polyaniline Modification","Engineering","Mechanical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/11039"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Monitoring wound healing is critical for improving patient outcomes, especially for chronic wounds, which often have complications like delayed healing and infections. Current methods for monitoring wound healing are invasive and costly. Also, these methods have a limited ability to provide real-time, continuous data. This study seeks to explore a graphene screen-printed electrode (SPE) electrochemical biosensor that is non-invasive and efficient to constantly monitor wound healing in real time. This research study focuses specifically on the electrochemical detection of the Human Neutrophil Elastase (HNE) and Secretory Leukocyte Protease Inhibitor (SLPI), which is one of the most abundant neutral proteinases in chronic wounds. Studies have found that Human Neutrophil Elastase (HNE) activity is elevated in chronic wounds, while diminished in healing wounds. Investigating the electrochemical responses of Human Neutrophil Elastase (HNE) and Secretory Leukocyte Protease Inhibitor (SLPI) could lead to a possible marker regarding severe wound inflammation or infection.In this study, two different conductive polymer-based graphene inks were prepared: PEDOT:PSS and polyaniline (PANI). Cyclic voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS) testing showed that the PANI-based ink was more conductive than the PEDOT:PSS. Thus, graphene PANI ink is a preferred choice regarding further sensor development. An optimized volume of PANI-graphene ink was established to achieve surface stability and ensure good conductivity. The electrode surface was functionalized using EDC/NHS chemistry to enable biomolecule immobilization. The sensors were tested at different HNE and SLPI antigen concentrations to determine the sensors' sensitivity, selectivity, and dynamic range of detection. The results have shown that the impedance response increased with HNE and SLPI concentration, confirming antigen binding and verifying the sensor’s good sensitivity with a wide detection range. LOD were calculated at 0.76 ng/mL for HNE detection and 0.37 ng/mL for SLPI detection. The reproducibility results yielded an RSD of approximately 3.3% across three sensors. This work seeks to develop an electrochemical platform that is reliable and reproducible for detecting HNE and SLPI as a wound biomarker. PANI-graphene ink offers a combination of both conductivity and stability. This combination shows its potential for point-of-care wound monitoring applications."]},{"key":"dc:title","label":"Title","values":["Graphene Screen-Printed Electrode for Wound-Related Biosensing"]}]}],"canonical_facts":{"dc:contributor":["Ali Ashraf, Ph.D.","Ashok Kumar, Ph.D.","Wilfrido Moreno, Ph.D.","Piyush Koria, Ph.D."],"dc:creator":["Sriviroch, Chanyapat"],"dc:date":["2025-10-23T07:00:00Z"],"dc:description":["Monitoring wound healing is critical for improving patient outcomes, especially for chronic wounds, which often have complications like delayed healing and infections. Current methods for monitoring wound healing are invasive and costly. Also, these methods have a limited ability to provide real-time, continuous data. This study seeks to explore a graphene screen-printed electrode (SPE) electrochemical biosensor that is non-invasive and efficient to constantly monitor wound healing in real time. This research study focuses specifically on the electrochemical detection of the Human Neutrophil Elastase (HNE) and Secretory Leukocyte Protease Inhibitor (SLPI), which is one of the most abundant neutral proteinases in chronic wounds. Studies have found that Human Neutrophil Elastase (HNE) activity is elevated in chronic wounds, while diminished in healing wounds. Investigating the electrochemical responses of Human Neutrophil Elastase (HNE) and Secretory Leukocyte Protease Inhibitor (SLPI) could lead to a possible marker regarding severe wound inflammation or infection.In this study, two different conductive polymer-based graphene inks were prepared: PEDOT:PSS and polyaniline (PANI). Cyclic voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS) testing showed that the PANI-based ink was more conductive than the PEDOT:PSS. Thus, graphene PANI ink is a preferred choice regarding further sensor development. An optimized volume of PANI-graphene ink was established to achieve surface stability and ensure good conductivity. The electrode surface was functionalized using EDC/NHS chemistry to enable biomolecule immobilization. The sensors were tested at different HNE and SLPI antigen concentrations to determine the sensors' sensitivity, selectivity, and dynamic range of detection. The results have shown that the impedance response increased with HNE and SLPI concentration, confirming antigen binding and verifying the sensor’s good sensitivity with a wide detection range. LOD were calculated at 0.76 ng/mL for HNE detection and 0.37 ng/mL for SLPI detection. The reproducibility results yielded an RSD of approximately 3.3% across three sensors. This work seeks to develop an electrochemical platform that is reliable and reproducible for detecting HNE and SLPI as a wound biomarker. PANI-graphene ink offers a combination of both conductivity and stability. This combination shows its potential for point-of-care wound monitoring applications."],"dc:identifier":["https://digitalcommons.usf.edu/etd/11039"],"dc:subject":["Biomarker Detection","Electrochemical Analysis","Nanomaterials","Point-of-Care Diagnostics","Polyaniline Modification","Engineering","Mechanical Engineering"],"dc:title":["Graphene Screen-Printed Electrode for Wound-Related Biosensing"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Thesis","M.S.M.E."],"thesis:degree_name":["MS in Mechanical Engineering (M.S.M.E.)"],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:49:16Z"}