{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-1725"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-1725","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"Bulk Silicon Based Temperature Sensor","abstract":"A bulk silicon temperature sensor is fabricated in this work. The objective is to develop a low-cost high resolution temperature sensor. The target applications are a Conductivity-Temperature-Depth (CTD) sensor for oceanic applications and a magnetocaloric microcooler. The properties of silicon are modified by thermal diffusion of gold. Gold is a fast diffuser in silicon and its diffusion contributes to the increase in resistivity of silicon. The addition of gold to n-type silicon creates a negative temperature coefficient device. The effect of the diffusing environment was investigated by diffusing in oxygen and nitrogen ambient at various temperatures. The influence of area of gold diffusion was also investigated. The effect of temperature on resistance was measured and was used to calibrate the sensor. Although the sensors fabricated in an oxygen environment have an exponential type response, they can be used in the CTD application because of enhanced sensitivity in the 10˚C - 30˚C temperature range. Sensors fabricated in a nitrogen environment are found to have linear response with sensitivity ranging from 7Ω/˚C to 3000Ω/˚C and can be used for both applications. The fabricated sensors have a 0.1˚C resolution.","abstract_html":"A bulk silicon temperature sensor is fabricated in this work. The objective is to develop a low-cost high resolution temperature sensor. The target applications are a Conductivity-Temperature-Depth (CTD) sensor for oceanic applications and a magnetocaloric microcooler. The properties of silicon are modified by thermal diffusion of gold. Gold is a fast diffuser in silicon and its diffusion contributes to the increase in resistivity of silicon. The addition of gold to n-type silicon creates a negative temperature coefficient device. The effect of the diffusing environment was investigated by diffusing in oxygen and nitrogen ambient at various temperatures. The influence of area of gold diffusion was also investigated. The effect of temperature on resistance was measured and was used to calibrate the sensor. Although the sensors fabricated in an oxygen environment have an exponential type response, they can be used in the CTD application because of enhanced sensitivity in the 10˚C - 30˚C temperature range. Sensors fabricated in a nitrogen environment are found to have linear response with sensitivity ranging from 7Ω/˚C to 3000Ω/˚C and can be used for both applications. The fabricated sensors have a 0.1˚C resolution.","abstract_has_math":false,"creators":["Kishanlal Premchand, Bharath Bethala"],"institution":"University of South Florida","degree_name":null,"degree_level":"Thesis","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["Shekhar Bhansali, Ph.D.","Larry Langebrake, P.E.","Kenneth Buckle, Ph.D.","Sang Chae Kim, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-10-31T08:00:00Z","date_published":"2005-10-31T08:00:00Z","updated_at":"2026-11-19T08:34:07Z","subjects":["Transition elements","Gold","Diffusion","Resistivity","Resistance","American Studies","Arts and Humanities"],"languages":["EN-US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/726","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/726","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-1725","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Shekhar Bhansali, Ph.D.","Larry Langebrake, P.E.","Kenneth Buckle, Ph.D.","Sang Chae Kim, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Kishanlal Premchand, Bharath Bethala"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2005-10-31T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.S.E.E."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Transition elements","Gold","Diffusion","Resistivity","Resistance","American Studies","Arts and Humanities"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["EN-US"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["default"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/726"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A bulk silicon temperature sensor is fabricated in this work. The objective is to develop a low-cost high resolution temperature sensor. The target applications are a Conductivity-Temperature-Depth (CTD) sensor for oceanic applications and a magnetocaloric microcooler. The properties of silicon are modified by thermal diffusion of gold. Gold is a fast diffuser in silicon and its diffusion contributes to the increase in resistivity of silicon. The addition of gold to n-type silicon creates a negative temperature coefficient device. The effect of the diffusing environment was investigated by diffusing in oxygen and nitrogen ambient at various temperatures. The influence of area of gold diffusion was also investigated. The effect of temperature on resistance was measured and was used to calibrate the sensor. Although the sensors fabricated in an oxygen environment have an exponential type response, they can be used in the CTD application because of enhanced sensitivity in the 10˚C - 30˚C temperature range. Sensors fabricated in a nitrogen environment are found to have linear response with sensitivity ranging from 7Ω/˚C to 3000Ω/˚C and can be used for both applications. The fabricated sensors have a 0.1˚C resolution."]},{"key":"dc:title","label":"Title","values":["Bulk Silicon Based Temperature Sensor"]}]}],"canonical_facts":{"dc:contributor":["Shekhar Bhansali, Ph.D.","Larry Langebrake, P.E.","Kenneth Buckle, Ph.D.","Sang Chae Kim, Ph.D."],"dc:creator":["Kishanlal Premchand, Bharath Bethala"],"dc:date":["2005-10-31T08:00:00Z"],"dc:description":["A bulk silicon temperature sensor is fabricated in this work. The objective is to develop a low-cost high resolution temperature sensor. The target applications are a Conductivity-Temperature-Depth (CTD) sensor for oceanic applications and a magnetocaloric microcooler. The properties of silicon are modified by thermal diffusion of gold. Gold is a fast diffuser in silicon and its diffusion contributes to the increase in resistivity of silicon. The addition of gold to n-type silicon creates a negative temperature coefficient device. The effect of the diffusing environment was investigated by diffusing in oxygen and nitrogen ambient at various temperatures. The influence of area of gold diffusion was also investigated. The effect of temperature on resistance was measured and was used to calibrate the sensor. Although the sensors fabricated in an oxygen environment have an exponential type response, they can be used in the CTD application because of enhanced sensitivity in the 10˚C - 30˚C temperature range. Sensors fabricated in a nitrogen environment are found to have linear response with sensitivity ranging from 7Ω/˚C to 3000Ω/˚C and can be used for both applications. The fabricated sensors have a 0.1˚C resolution."],"dc:identifier":["https://digitalcommons.usf.edu/etd/726"],"dc:language":["EN-US"],"dc:rights.license":["default"],"dc:subject":["Transition elements","Gold","Diffusion","Resistivity","Resistance","American Studies","Arts and Humanities"],"dc:title":["Bulk Silicon Based Temperature Sensor"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Thesis","M.S.E.E."],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:34:07Z"}