{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-2078"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-2078","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"Numerical Simulation of Thermal Comfort and Contaminant Transport in Air Conditioned Rooms","abstract":"Health care facilities, offices, as well as workshops and other commercial occupancies, require ventilation and air conditioning for thermal comfort and removal of contaminants and other pollutions. A good design of ventilation and air conditioning provides a healthy and comfortable environment for patients, workers, and visitors. The increasing developments of computational fluid dynamics (CFD) in the recent years have opened the possibilities of low-cost yet effective method for improving HVAC systems in design phase, with less experiment required. This work presents numerical simulations of thermal comfort and contaminant removal for two typical working spaces where these factors are critical: a hospital operating room with various configurations of inlet and outlet arrangements, and an office with two cases of air distribution systems: underfloor and overhead, also with alternative cases. The 2-D simulation approach was employed. Temperature, relative humidity, contaminant concentration, thermal sensation, predicted mean vote (PMV), and contaminant removal factor were computed and used for assessing thermal comfort and contaminant removal characteristics of the office room and operating room. The result shows good agreements with experimental data taken from related literature.","abstract_html":"Health care facilities, offices, as well as workshops and other commercial occupancies, require ventilation and air conditioning for thermal comfort and removal of contaminants and other pollutions. A good design of ventilation and air conditioning provides a healthy and comfortable environment for patients, workers, and visitors. The increasing developments of computational fluid dynamics (CFD) in the recent years have opened the possibilities of low-cost yet effective method for improving HVAC systems in design phase, with less experiment required. This work presents numerical simulations of thermal comfort and contaminant removal for two typical working spaces where these factors are critical: a hospital operating room with various configurations of inlet and outlet arrangements, and an office with two cases of air distribution systems: underfloor and overhead, also with alternative cases. The 2-D simulation approach was employed. Temperature, relative humidity, contaminant concentration, thermal sensation, predicted mean vote (PMV), and contaminant removal factor were computed and used for assessing thermal comfort and contaminant removal characteristics of the office room and operating room. The result shows good agreements with experimental data taken from related literature.","abstract_has_math":false,"creators":["Ho, Son Hong"],"institution":"University of South Florida","degree_name":null,"degree_level":"Thesis","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Muhammad Rahman, Ph.D.","Ashok Kumar, Ph.D.","Thomas Eason, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004-11-08T08:00:00Z","date_published":"2004-11-08T08:00:00Z","updated_at":"2026-11-19T08:39:12Z","subjects":["computational fluid dynamics","multi-component flow","relative humidity","ventilation","heat and mass transfer","American Studies","Arts and Humanities"],"languages":["EN-US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/1079","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/1079","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-2078","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Muhammad Rahman, Ph.D.","Ashok Kumar, Ph.D.","Thomas Eason, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Ho, Son Hong"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2004-11-08T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.S.M.E."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["computational fluid dynamics","multi-component flow","relative humidity","ventilation","heat and mass transfer","American Studies","Arts and Humanities"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["EN-US"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["default"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/1079"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Health care facilities, offices, as well as workshops and other commercial occupancies, require ventilation and air conditioning for thermal comfort and removal of contaminants and other pollutions. A good design of ventilation and air conditioning provides a healthy and comfortable environment for patients, workers, and visitors. The increasing developments of computational fluid dynamics (CFD) in the recent years have opened the possibilities of low-cost yet effective method for improving HVAC systems in design phase, with less experiment required. This work presents numerical simulations of thermal comfort and contaminant removal for two typical working spaces where these factors are critical: a hospital operating room with various configurations of inlet and outlet arrangements, and an office with two cases of air distribution systems: underfloor and overhead, also with alternative cases. The 2-D simulation approach was employed. Temperature, relative humidity, contaminant concentration, thermal sensation, predicted mean vote (PMV), and contaminant removal factor were computed and used for assessing thermal comfort and contaminant removal characteristics of the office room and operating room. The result shows good agreements with experimental data taken from related literature."]},{"key":"dc:title","label":"Title","values":["Numerical Simulation of Thermal Comfort and Contaminant Transport in Air Conditioned Rooms"]}]}],"canonical_facts":{"dc:contributor":["Muhammad Rahman, Ph.D.","Ashok Kumar, Ph.D.","Thomas Eason, Ph.D."],"dc:creator":["Ho, Son Hong"],"dc:date":["2004-11-08T08:00:00Z"],"dc:description":["Health care facilities, offices, as well as workshops and other commercial occupancies, require ventilation and air conditioning for thermal comfort and removal of contaminants and other pollutions. A good design of ventilation and air conditioning provides a healthy and comfortable environment for patients, workers, and visitors. The increasing developments of computational fluid dynamics (CFD) in the recent years have opened the possibilities of low-cost yet effective method for improving HVAC systems in design phase, with less experiment required. This work presents numerical simulations of thermal comfort and contaminant removal for two typical working spaces where these factors are critical: a hospital operating room with various configurations of inlet and outlet arrangements, and an office with two cases of air distribution systems: underfloor and overhead, also with alternative cases. The 2-D simulation approach was employed. Temperature, relative humidity, contaminant concentration, thermal sensation, predicted mean vote (PMV), and contaminant removal factor were computed and used for assessing thermal comfort and contaminant removal characteristics of the office room and operating room. The result shows good agreements with experimental data taken from related literature."],"dc:identifier":["https://digitalcommons.usf.edu/etd/1079"],"dc:language":["EN-US"],"dc:rights.license":["default"],"dc:subject":["computational fluid dynamics","multi-component flow","relative humidity","ventilation","heat and mass transfer","American Studies","Arts and Humanities"],"dc:title":["Numerical Simulation of Thermal Comfort and Contaminant Transport in Air Conditioned Rooms"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Thesis","M.S.M.E."],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:39:12Z"}