{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-3511"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-3511","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"Vibration Level Characterization from a Needle Gun Used on U.S. Naval Vessels","abstract":"United States (U.S.) Navy sailors are exposed to a very large number of hazards, both chemical and physical. Occupational vibration from pneumatic air tools is one of the potential exposure hazards. There are very limited data as to the exposures to one type of tool, a needle gun or needle scaler, used by the sailors.The purpose of this study was to characterize the vibration levels generated by a needle gun used in the U.S. Navy. The design of the study evaluated the difference pressure had on the acceleration levels generated from the needle scaler. Five subjects were used in the evaluation of the tool. Each subject was required to hold the tool for twenty seconds activated without contact and activated on a surface and at two different pressures, 60 and 80 pound per square inch (psi). Each subject repeated each of the conditions three times for a total of 12 measurements. Each subject was also required to hold the tool in hand without the tool activated. The measurements were collected from an accelerometer on the needle gun following ISO 5349-1:2001 and ISO 5349-2:2001 methods. Significant differences were observed individually in pressure (p< 0.0001), contact (p< 0.0001)), and subjects (p< 0.001). In addition, there was a significant interaction between contact and pressure (p< 0.001). It was concluded that U.S. Navy sailors are not likely at significant risk to Hand-Arm Vibration Syndrome for lifetime exposures to hand transmitted vibration.","abstract_html":"United States (U.S.) Navy sailors are exposed to a very large number of hazards, both chemical and physical. Occupational vibration from pneumatic air tools is one of the potential exposure hazards. There are very limited data as to the exposures to one type of tool, a needle gun or needle scaler, used by the sailors.The purpose of this study was to characterize the vibration levels generated by a needle gun used in the U.S. Navy. The design of the study evaluated the difference pressure had on the acceleration levels generated from the needle scaler. Five subjects were used in the evaluation of the tool. Each subject was required to hold the tool for twenty seconds activated without contact and activated on a surface and at two different pressures, 60 and 80 pound per square inch (psi). Each subject repeated each of the conditions three times for a total of 12 measurements. Each subject was also required to hold the tool in hand without the tool activated. The measurements were collected from an accelerometer on the needle gun following ISO 5349-1:2001 and ISO 5349-2:2001 methods. Significant differences were observed individually in pressure (p&lt; 0.0001), contact (p&lt; 0.0001)), and subjects (p&lt; 0.001). In addition, there was a significant interaction between contact and pressure (p&lt; 0.001). It was concluded that U.S. Navy sailors are not likely at significant risk to Hand-Arm Vibration Syndrome for lifetime exposures to hand transmitted vibration.","abstract_has_math":false,"creators":["Dunn, Scott E"],"institution":"University of South Florida","degree_name":null,"degree_level":"Thesis","degree_discipline":"Public Health","degree_department":null,"school":null,"contributors":["Thomas E. Bernard, Ph.D.","Steve Mlynarek, Ph.D.","Andrea Spehar, D.V.M, M.P.H., J.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006-01-01T08:00:00Z","date_published":"2006-01-01T08:00:00Z","updated_at":"2026-11-19T08:35:37Z","subjects":["Hand-arm vibration","Needle gun","Needle scaler","Percussive tool","Vibration white finger","American Studies","Arts and Humanities"],"languages":["EN-US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/2512","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/2512","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-3511","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Thomas E. Bernard, Ph.D.","Steve Mlynarek, Ph.D.","Andrea Spehar, D.V.M, M.P.H., J.D."]},{"key":"dc:creator","label":"Author","values":["Dunn, Scott E"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2006-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Public Health"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.A."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Hand-arm vibration","Needle gun","Needle scaler","Percussive tool","Vibration white finger","American Studies","Arts and Humanities"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["EN-US"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["default"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/2512"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["United States (U.S.) Navy sailors are exposed to a very large number of hazards, both chemical and physical. Occupational vibration from pneumatic air tools is one of the potential exposure hazards. There are very limited data as to the exposures to one type of tool, a needle gun or needle scaler, used by the sailors.The purpose of this study was to characterize the vibration levels generated by a needle gun used in the U.S. Navy. The design of the study evaluated the difference pressure had on the acceleration levels generated from the needle scaler. Five subjects were used in the evaluation of the tool. Each subject was required to hold the tool for twenty seconds activated without contact and activated on a surface and at two different pressures, 60 and 80 pound per square inch (psi). Each subject repeated each of the conditions three times for a total of 12 measurements. Each subject was also required to hold the tool in hand without the tool activated. The measurements were collected from an accelerometer on the needle gun following ISO 5349-1:2001 and ISO 5349-2:2001 methods. Significant differences were observed individually in pressure (p< 0.0001), contact (p< 0.0001)), and subjects (p< 0.001). In addition, there was a significant interaction between contact and pressure (p< 0.001). It was concluded that U.S. Navy sailors are not likely at significant risk to Hand-Arm Vibration Syndrome for lifetime exposures to hand transmitted vibration."]},{"key":"dc:title","label":"Title","values":["Vibration Level Characterization from a Needle Gun Used on U.S. Naval Vessels"]}]}],"canonical_facts":{"dc:contributor":["Thomas E. Bernard, Ph.D.","Steve Mlynarek, Ph.D.","Andrea Spehar, D.V.M, M.P.H., J.D."],"dc:creator":["Dunn, Scott E"],"dc:date":["2006-01-01T08:00:00Z"],"dc:description":["United States (U.S.) Navy sailors are exposed to a very large number of hazards, both chemical and physical. Occupational vibration from pneumatic air tools is one of the potential exposure hazards. There are very limited data as to the exposures to one type of tool, a needle gun or needle scaler, used by the sailors.The purpose of this study was to characterize the vibration levels generated by a needle gun used in the U.S. Navy. The design of the study evaluated the difference pressure had on the acceleration levels generated from the needle scaler. Five subjects were used in the evaluation of the tool. Each subject was required to hold the tool for twenty seconds activated without contact and activated on a surface and at two different pressures, 60 and 80 pound per square inch (psi). Each subject repeated each of the conditions three times for a total of 12 measurements. Each subject was also required to hold the tool in hand without the tool activated. The measurements were collected from an accelerometer on the needle gun following ISO 5349-1:2001 and ISO 5349-2:2001 methods. Significant differences were observed individually in pressure (p< 0.0001), contact (p< 0.0001)), and subjects (p< 0.001). In addition, there was a significant interaction between contact and pressure (p< 0.001). It was concluded that U.S. Navy sailors are not likely at significant risk to Hand-Arm Vibration Syndrome for lifetime exposures to hand transmitted vibration."],"dc:identifier":["https://digitalcommons.usf.edu/etd/2512"],"dc:language":["EN-US"],"dc:rights.license":["default"],"dc:subject":["Hand-arm vibration","Needle gun","Needle scaler","Percussive tool","Vibration white finger","American Studies","Arts and Humanities"],"dc:title":["Vibration Level Characterization from a Needle Gun Used on U.S. Naval Vessels"],"thesis:degree_discipline":["Public Health"],"thesis:degree_level":["Thesis","M.A."],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:35:37Z"}