{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-3783"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-3783","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"Salinity (Conductivity) Sensor Based on Parallel Plate Capacitors","abstract":"This work is aimed at developing a high sensitivity salinity (conductivity) sensor for marine applications. The principle of sensing involves the use of parallel plate capacitors, which minimizes the proximity effects associated with inductive measurement techniques. The barrier properties of two different materials, AZ5214 and Honeywell's ACCUFLO T3027, were investigated for use as the insulation layer for the sensor. Impedance analysis performed on the two coatings using Agilent's 4924A Precision Impedance Analyzer served to prove that ACCUFLO was a better dielectric material for this application when compared to AZ5214.Two separate detection circuits have been proposed for the salinity sensor. In the Twin-T filter method, a variation in capacitance tends to shift the resonant frequency of a Twin-T oscillator, comprising the sensor. Simulations of the oscillator circuit were performed using Pspice. Experiments were performed on calibrated ocean water samples of 34.996 psu and a shift of 410 Hz/psu was obtained. To avoid the problems associated with the frequency drift in the oscillator, an alternate detection scheme is proposed which employs frequency-to-voltage converters. The sensitivity of this detection scheme was observed to be 10 mV/psu.","abstract_html":"This work is aimed at developing a high sensitivity salinity (conductivity) sensor for marine applications. The principle of sensing involves the use of parallel plate capacitors, which minimizes the proximity effects associated with inductive measurement techniques. The barrier properties of two different materials, AZ5214 and Honeywell&#x27;s ACCUFLO T3027, were investigated for use as the insulation layer for the sensor. Impedance analysis performed on the two coatings using Agilent&#x27;s 4924A Precision Impedance Analyzer served to prove that ACCUFLO was a better dielectric material for this application when compared to AZ5214.Two separate detection circuits have been proposed for the salinity sensor. In the Twin-T filter method, a variation in capacitance tends to shift the resonant frequency of a Twin-T oscillator, comprising the sensor. Simulations of the oscillator circuit were performed using Pspice. Experiments were performed on calibrated ocean water samples of 34.996 psu and a shift of 410 Hz/psu was obtained. To avoid the problems associated with the frequency drift in the oscillator, an alternate detection scheme is proposed which employs frequency-to-voltage converters. The sensitivity of this detection scheme was observed to be 10 mV/psu.","abstract_has_math":false,"creators":["Bhat, Shreyas"],"institution":"University of South Florida","degree_name":null,"degree_level":"Thesis","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["Shekhar Bhansali, Ph.D.","Larry Langebrake, P.E.","Rudy Schlaf, Ph.D.","Babu Joseph, Ph.D.","Kendra Daly, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-10-22T07:00:00Z","date_published":"2005-10-22T07:00:00Z","updated_at":"2026-11-19T08:35:37Z","subjects":["Impedance","oscillator","dielectric","polarization","complex permittivity","American Studies","Arts and Humanities"],"languages":["EN-US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/2784","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/2784","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-3783","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Shekhar Bhansali, Ph.D.","Larry Langebrake, P.E.","Rudy Schlaf, Ph.D.","Babu Joseph, Ph.D.","Kendra Daly, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Bhat, Shreyas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2005-10-22T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.S.E.E."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Impedance","oscillator","dielectric","polarization","complex permittivity","American Studies","Arts and Humanities"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["EN-US"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["default"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/2784"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This work is aimed at developing a high sensitivity salinity (conductivity) sensor for marine applications. The principle of sensing involves the use of parallel plate capacitors, which minimizes the proximity effects associated with inductive measurement techniques. The barrier properties of two different materials, AZ5214 and Honeywell's ACCUFLO T3027, were investigated for use as the insulation layer for the sensor. Impedance analysis performed on the two coatings using Agilent's 4924A Precision Impedance Analyzer served to prove that ACCUFLO was a better dielectric material for this application when compared to AZ5214.Two separate detection circuits have been proposed for the salinity sensor. In the Twin-T filter method, a variation in capacitance tends to shift the resonant frequency of a Twin-T oscillator, comprising the sensor. Simulations of the oscillator circuit were performed using Pspice. Experiments were performed on calibrated ocean water samples of 34.996 psu and a shift of 410 Hz/psu was obtained. To avoid the problems associated with the frequency drift in the oscillator, an alternate detection scheme is proposed which employs frequency-to-voltage converters. The sensitivity of this detection scheme was observed to be 10 mV/psu."]},{"key":"dc:title","label":"Title","values":["Salinity (Conductivity) Sensor Based on Parallel Plate Capacitors"]}]}],"canonical_facts":{"dc:contributor":["Shekhar Bhansali, Ph.D.","Larry Langebrake, P.E.","Rudy Schlaf, Ph.D.","Babu Joseph, Ph.D.","Kendra Daly, Ph.D."],"dc:creator":["Bhat, Shreyas"],"dc:date":["2005-10-22T07:00:00Z"],"dc:description":["This work is aimed at developing a high sensitivity salinity (conductivity) sensor for marine applications. The principle of sensing involves the use of parallel plate capacitors, which minimizes the proximity effects associated with inductive measurement techniques. The barrier properties of two different materials, AZ5214 and Honeywell's ACCUFLO T3027, were investigated for use as the insulation layer for the sensor. Impedance analysis performed on the two coatings using Agilent's 4924A Precision Impedance Analyzer served to prove that ACCUFLO was a better dielectric material for this application when compared to AZ5214.Two separate detection circuits have been proposed for the salinity sensor. In the Twin-T filter method, a variation in capacitance tends to shift the resonant frequency of a Twin-T oscillator, comprising the sensor. Simulations of the oscillator circuit were performed using Pspice. Experiments were performed on calibrated ocean water samples of 34.996 psu and a shift of 410 Hz/psu was obtained. To avoid the problems associated with the frequency drift in the oscillator, an alternate detection scheme is proposed which employs frequency-to-voltage converters. The sensitivity of this detection scheme was observed to be 10 mV/psu."],"dc:identifier":["https://digitalcommons.usf.edu/etd/2784"],"dc:language":["EN-US"],"dc:rights.license":["default"],"dc:subject":["Impedance","oscillator","dielectric","polarization","complex permittivity","American Studies","Arts and Humanities"],"dc:title":["Salinity (Conductivity) Sensor Based on Parallel Plate Capacitors"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Thesis","M.S.E.E."],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:35:37Z"}