{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-3971"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-3971","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"Sorption Of Organic Vapors By Copolymers Of Poly (Styrene-Butadiene) Using A Piezoelectric Microbalance","abstract":"Thickness shear mode (TSM) sensors, also known as quartz crystal microbalances (QCM) are a class of acoustic wave sensors that have been used for gas phase sensing. In this thesis this device is used to measure vapor-liquid equilibrium data for copolymers of poly(styrene-butadiene) at 294K. Copolymers of poly(styrene-butadiene) with varying percentages of styrene (85%, 45% and 21 %) were studied with benzene, n-hexane, dichloroethane and chloroform as solvents. Literature data for pure polystyrene/benzene and polystyrene/chloroform and polybutadiene/benzene were obtained to complement the measured data. Obtained experimental data were fit with a modified Flory-Huggins model and compared with the predictions of three models (UNIFAC-FV, Entropic-FV, and GK-FV). Flory-Huggins model gave a good quantitative fit for the solvent activities in the copolymer solutions. All models UNIFAC-FV, GK-FV and Entropic-FV gave good predictions for poly(85% styrene-15% butadiene) copolymer/solvent and poly(45% styrene-55% butadiene) copolymer/solvent systems. All models could not predict well for poly(21% styrene-79% butadiene)/ chloroform system, yet the same models gave good predictions for the same copolymer with benzene, n-hexane and dichloroethane systems. All models predicted very well for 21% styrene in copolymer and n-hexane system and did not do well with chloroform as solvent. GK-FV and entropic-FV predicted better for 21% styrene in copolymer and solvents except chloroform. A fully instrumented and automated test-bed consisting of a temperature controlled vapor dilution system, a precision impedance analyzer, and computer for data acquisition in Labview was developed in-house to evaluate the performance of the coated TSM devices in sensor applications as well as in sorption data measurement.","abstract_html":"Thickness shear mode (TSM) sensors, also known as quartz crystal microbalances (QCM) are a class of acoustic wave sensors that have been used for gas phase sensing. In this thesis this device is used to measure vapor-liquid equilibrium data for copolymers of poly(styrene-butadiene) at 294K. Copolymers of poly(styrene-butadiene) with varying percentages of styrene (85%, 45% and 21 %) were studied with benzene, n-hexane, dichloroethane and chloroform as solvents. Literature data for pure polystyrene/benzene and polystyrene/chloroform and polybutadiene/benzene were obtained to complement the measured data. Obtained experimental data were fit with a modified Flory-Huggins model and compared with the predictions of three models (UNIFAC-FV, Entropic-FV, and GK-FV). Flory-Huggins model gave a good quantitative fit for the solvent activities in the copolymer solutions. All models UNIFAC-FV, GK-FV and Entropic-FV gave good predictions for poly(85% styrene-15% butadiene) copolymer/solvent and poly(45% styrene-55% butadiene) copolymer/solvent systems. All models could not predict well for poly(21% styrene-79% butadiene)/ chloroform system, yet the same models gave good predictions for the same copolymer with benzene, n-hexane and dichloroethane systems. All models predicted very well for 21% styrene in copolymer and n-hexane system and did not do well with chloroform as solvent. GK-FV and entropic-FV predicted better for 21% styrene in copolymer and solvents except chloroform. A fully instrumented and automated test-bed consisting of a temperature controlled vapor dilution system, a precision impedance analyzer, and computer for data acquisition in Labview was developed in-house to evaluate the performance of the coated TSM devices in sensor applications as well as in sorption data measurement.","abstract_has_math":false,"creators":["Upadhyayula, Anant K."],"institution":"University of South Florida","degree_name":null,"degree_level":"Thesis","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":["Venkat R. Bhethanabotla, Ph.D.","Babu Joseph, Ph.D.","Scott W. Campbell, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-01-01T08:00:00Z","date_published":"2005-01-01T08:00:00Z","updated_at":"2026-11-19T08:34:51Z","subjects":["QCM","VLE","Benzene","N-hexane","Dichloroethane","Chloroform","American Studies","Arts and Humanities"],"languages":["EN-US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/2963","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/2963","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-3971","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Venkat R. Bhethanabotla, Ph.D.","Babu Joseph, Ph.D.","Scott W. Campbell, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Upadhyayula, Anant K."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2005-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["QCM","VLE","Benzene","N-hexane","Dichloroethane","Chloroform","American Studies","Arts and Humanities"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["EN-US"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["default"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/2963"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thickness shear mode (TSM) sensors, also known as quartz crystal microbalances (QCM) are a class of acoustic wave sensors that have been used for gas phase sensing. In this thesis this device is used to measure vapor-liquid equilibrium data for copolymers of poly(styrene-butadiene) at 294K. Copolymers of poly(styrene-butadiene) with varying percentages of styrene (85%, 45% and 21 %) were studied with benzene, n-hexane, dichloroethane and chloroform as solvents. Literature data for pure polystyrene/benzene and polystyrene/chloroform and polybutadiene/benzene were obtained to complement the measured data. Obtained experimental data were fit with a modified Flory-Huggins model and compared with the predictions of three models (UNIFAC-FV, Entropic-FV, and GK-FV). Flory-Huggins model gave a good quantitative fit for the solvent activities in the copolymer solutions. All models UNIFAC-FV, GK-FV and Entropic-FV gave good predictions for poly(85% styrene-15% butadiene) copolymer/solvent and poly(45% styrene-55% butadiene) copolymer/solvent systems. All models could not predict well for poly(21% styrene-79% butadiene)/ chloroform system, yet the same models gave good predictions for the same copolymer with benzene, n-hexane and dichloroethane systems. All models predicted very well for 21% styrene in copolymer and n-hexane system and did not do well with chloroform as solvent. GK-FV and entropic-FV predicted better for 21% styrene in copolymer and solvents except chloroform. A fully instrumented and automated test-bed consisting of a temperature controlled vapor dilution system, a precision impedance analyzer, and computer for data acquisition in Labview was developed in-house to evaluate the performance of the coated TSM devices in sensor applications as well as in sorption data measurement."]},{"key":"dc:title","label":"Title","values":["Sorption Of Organic Vapors By Copolymers Of Poly (Styrene-Butadiene) Using A Piezoelectric Microbalance"]}]}],"canonical_facts":{"dc:contributor":["Venkat R. Bhethanabotla, Ph.D.","Babu Joseph, Ph.D.","Scott W. Campbell, Ph.D."],"dc:creator":["Upadhyayula, Anant K."],"dc:date":["2005-01-01T08:00:00Z"],"dc:description":["Thickness shear mode (TSM) sensors, also known as quartz crystal microbalances (QCM) are a class of acoustic wave sensors that have been used for gas phase sensing. In this thesis this device is used to measure vapor-liquid equilibrium data for copolymers of poly(styrene-butadiene) at 294K. Copolymers of poly(styrene-butadiene) with varying percentages of styrene (85%, 45% and 21 %) were studied with benzene, n-hexane, dichloroethane and chloroform as solvents. Literature data for pure polystyrene/benzene and polystyrene/chloroform and polybutadiene/benzene were obtained to complement the measured data. Obtained experimental data were fit with a modified Flory-Huggins model and compared with the predictions of three models (UNIFAC-FV, Entropic-FV, and GK-FV). Flory-Huggins model gave a good quantitative fit for the solvent activities in the copolymer solutions. All models UNIFAC-FV, GK-FV and Entropic-FV gave good predictions for poly(85% styrene-15% butadiene) copolymer/solvent and poly(45% styrene-55% butadiene) copolymer/solvent systems. All models could not predict well for poly(21% styrene-79% butadiene)/ chloroform system, yet the same models gave good predictions for the same copolymer with benzene, n-hexane and dichloroethane systems. All models predicted very well for 21% styrene in copolymer and n-hexane system and did not do well with chloroform as solvent. GK-FV and entropic-FV predicted better for 21% styrene in copolymer and solvents except chloroform. A fully instrumented and automated test-bed consisting of a temperature controlled vapor dilution system, a precision impedance analyzer, and computer for data acquisition in Labview was developed in-house to evaluate the performance of the coated TSM devices in sensor applications as well as in sorption data measurement."],"dc:identifier":["https://digitalcommons.usf.edu/etd/2963"],"dc:language":["EN-US"],"dc:rights.license":["default"],"dc:subject":["QCM","VLE","Benzene","N-hexane","Dichloroethane","Chloroform","American Studies","Arts and Humanities"],"dc:title":["Sorption Of Organic Vapors By Copolymers Of Poly (Styrene-Butadiene) Using A Piezoelectric Microbalance"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["Thesis","M.S."],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:34:51Z"}