{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-4188"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-4188","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"Modeling of Solar-Powered Single-Effect Absorption Cooling System and Supermarket Refrigeration/HVAC System","abstract":"This thesis consists of two different research problems. In the first one, the aim is to model and simulate a solar-powered, single-effect, absorption refrigeration system using a flat-plate solar collector and LiBr-H2O mixture as the working fluid. The cooling capacity and the coefficient of performance of the system are analyzed by varying all independent parameters, namely: evaporator pressure, condenser pressure, mass flow rate, LiBr concentration, and inlet generator temperature. The cooling performance of the system is compared with conventional vapor-compression systems for different refrigerants (R-134a, R-32, and R-22). The cooling performance is also assessed for a typical year in Tampa, Florida. Higher COP values are obtained for a lower LiBr concentration in the solution. The effects of evaporator and condenser pressures on the cooling capacity and cooling performance are found to be negligible. The LiBr-H2O solution shows higher cooling performance compared to other mixtures under the same absorption cooling cycle conditions. For typical year in Tampa, Florida, the model shows a constant coefficient of performance of 0.94. In the second problem, a numerical model is developed for a typical food retail store refrigeration/HVAC system to study the effects of indoor space conditions on supermarket energy consumption. Refrigerated display cases are normally rated at a store environment of 24ºC (75ºF) and a relative humidity of 55%. If the store can be maintained at lower relative humidity, significant quantities of refrigeration energy, defrost energy and anti-sweat heater energy can be saved. The numerical simulation is performed for a typical day in a standard store for each month of the year using the climate data for Tampa, Florida. This results in a 24 hour variation in the store relative humidity. Using these calculated hourly values of relative humidity for a typical 24 hour day, the store relative humidity distribution is calculated for a full year. The annual average supermarket relative humidity is found to be 51.1%. It is shown that for a 5% reduction in store relative humidity that the display case refrigeration load is reduced by 9.25%, and that results in total store energy load reduction of 4.84%. The results show good agreement with available experimental data.","abstract_html":"This thesis consists of two different research problems. In the first one, the aim is to model and simulate a solar-powered, single-effect, absorption refrigeration system using a flat-plate solar collector and LiBr-H2O mixture as the working fluid. The cooling capacity and the coefficient of performance of the system are analyzed by varying all independent parameters, namely: evaporator pressure, condenser pressure, mass flow rate, LiBr concentration, and inlet generator temperature. The cooling performance of the system is compared with conventional vapor-compression systems for different refrigerants (R-134a, R-32, and R-22). The cooling performance is also assessed for a typical year in Tampa, Florida. Higher COP values are obtained for a lower LiBr concentration in the solution. The effects of evaporator and condenser pressures on the cooling capacity and cooling performance are found to be negligible. The LiBr-H2O solution shows higher cooling performance compared to other mixtures under the same absorption cooling cycle conditions. For typical year in Tampa, Florida, the model shows a constant coefficient of performance of 0.94. In the second problem, a numerical model is developed for a typical food retail store refrigeration/HVAC system to study the effects of indoor space conditions on supermarket energy consumption. Refrigerated display cases are normally rated at a store environment of 24ºC (75ºF) and a relative humidity of 55%. If the store can be maintained at lower relative humidity, significant quantities of refrigeration energy, defrost energy and anti-sweat heater energy can be saved. The numerical simulation is performed for a typical day in a standard store for each month of the year using the climate data for Tampa, Florida. This results in a 24 hour variation in the store relative humidity. Using these calculated hourly values of relative humidity for a typical 24 hour day, the store relative humidity distribution is calculated for a full year. The annual average supermarket relative humidity is found to be 51.1%. It is shown that for a 5% reduction in store relative humidity that the display case refrigeration load is reduced by 9.25%, and that results in total store energy load reduction of 4.84%. The results show good agreement with available experimental data.","abstract_has_math":false,"creators":["Bahman, Ammar"],"institution":"University of South Florida","degree_name":null,"degree_level":"Thesis","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Muhammad M. Rahman, Ph.D.","Luis Rosario, Ph.D.","Frank Pyrtle, III, Ph.D.","Craig Lusk, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-01-01T08:00:00Z","date_published":"2011-01-01T08:00:00Z","updated_at":"2026-11-19T08:35:06Z","subjects":["Cooling Capacity","COP","Display Cases","Energy Consumption","Lithium Bromide","Store Relative Humidity","American Studies","Arts and Humanities","Mechanical Engineering"],"languages":["EN-US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/2993","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/2993","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-4188","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Muhammad M. Rahman, Ph.D.","Luis Rosario, Ph.D.","Frank Pyrtle, III, Ph.D.","Craig Lusk, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Bahman, Ammar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.S.M.E."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Cooling Capacity","COP","Display Cases","Energy Consumption","Lithium Bromide","Store Relative Humidity","American Studies","Arts and Humanities","Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["EN-US"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["default"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/2993"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This thesis consists of two different research problems. In the first one, the aim is to model and simulate a solar-powered, single-effect, absorption refrigeration system using a flat-plate solar collector and LiBr-H2O mixture as the working fluid. The cooling capacity and the coefficient of performance of the system are analyzed by varying all independent parameters, namely: evaporator pressure, condenser pressure, mass flow rate, LiBr concentration, and inlet generator temperature. The cooling performance of the system is compared with conventional vapor-compression systems for different refrigerants (R-134a, R-32, and R-22). The cooling performance is also assessed for a typical year in Tampa, Florida. Higher COP values are obtained for a lower LiBr concentration in the solution. The effects of evaporator and condenser pressures on the cooling capacity and cooling performance are found to be negligible. The LiBr-H2O solution shows higher cooling performance compared to other mixtures under the same absorption cooling cycle conditions. For typical year in Tampa, Florida, the model shows a constant coefficient of performance of 0.94. In the second problem, a numerical model is developed for a typical food retail store refrigeration/HVAC system to study the effects of indoor space conditions on supermarket energy consumption. Refrigerated display cases are normally rated at a store environment of 24ºC (75ºF) and a relative humidity of 55%. If the store can be maintained at lower relative humidity, significant quantities of refrigeration energy, defrost energy and anti-sweat heater energy can be saved. The numerical simulation is performed for a typical day in a standard store for each month of the year using the climate data for Tampa, Florida. This results in a 24 hour variation in the store relative humidity. Using these calculated hourly values of relative humidity for a typical 24 hour day, the store relative humidity distribution is calculated for a full year. The annual average supermarket relative humidity is found to be 51.1%. It is shown that for a 5% reduction in store relative humidity that the display case refrigeration load is reduced by 9.25%, and that results in total store energy load reduction of 4.84%. The results show good agreement with available experimental data."]},{"key":"dc:title","label":"Title","values":["Modeling of Solar-Powered Single-Effect Absorption Cooling System and Supermarket Refrigeration/HVAC System"]}]}],"canonical_facts":{"dc:contributor":["Muhammad M. Rahman, Ph.D.","Luis Rosario, Ph.D.","Frank Pyrtle, III, Ph.D.","Craig Lusk, Ph.D."],"dc:creator":["Bahman, Ammar"],"dc:date":["2011-01-01T08:00:00Z"],"dc:description":["This thesis consists of two different research problems. In the first one, the aim is to model and simulate a solar-powered, single-effect, absorption refrigeration system using a flat-plate solar collector and LiBr-H2O mixture as the working fluid. The cooling capacity and the coefficient of performance of the system are analyzed by varying all independent parameters, namely: evaporator pressure, condenser pressure, mass flow rate, LiBr concentration, and inlet generator temperature. The cooling performance of the system is compared with conventional vapor-compression systems for different refrigerants (R-134a, R-32, and R-22). The cooling performance is also assessed for a typical year in Tampa, Florida. Higher COP values are obtained for a lower LiBr concentration in the solution. The effects of evaporator and condenser pressures on the cooling capacity and cooling performance are found to be negligible. The LiBr-H2O solution shows higher cooling performance compared to other mixtures under the same absorption cooling cycle conditions. For typical year in Tampa, Florida, the model shows a constant coefficient of performance of 0.94. In the second problem, a numerical model is developed for a typical food retail store refrigeration/HVAC system to study the effects of indoor space conditions on supermarket energy consumption. Refrigerated display cases are normally rated at a store environment of 24ºC (75ºF) and a relative humidity of 55%. If the store can be maintained at lower relative humidity, significant quantities of refrigeration energy, defrost energy and anti-sweat heater energy can be saved. The numerical simulation is performed for a typical day in a standard store for each month of the year using the climate data for Tampa, Florida. This results in a 24 hour variation in the store relative humidity. Using these calculated hourly values of relative humidity for a typical 24 hour day, the store relative humidity distribution is calculated for a full year. The annual average supermarket relative humidity is found to be 51.1%. It is shown that for a 5% reduction in store relative humidity that the display case refrigeration load is reduced by 9.25%, and that results in total store energy load reduction of 4.84%. The results show good agreement with available experimental data."],"dc:identifier":["https://digitalcommons.usf.edu/etd/2993"],"dc:language":["EN-US"],"dc:rights.license":["default"],"dc:subject":["Cooling Capacity","COP","Display Cases","Energy Consumption","Lithium Bromide","Store Relative Humidity","American Studies","Arts and Humanities","Mechanical Engineering"],"dc:title":["Modeling of Solar-Powered Single-Effect Absorption Cooling System and Supermarket Refrigeration/HVAC System"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Thesis","M.S.M.E."],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:35:06Z"}