{"id":{"repo_id":"usf","oai_identifier":"oai:digitalcommons.usf.edu:etd-4646"},"canonical_url":"https://search.ndltd.org/etd/usf/oai:digitalcommons.usf.edu:etd-4646","repository":{"repo_id":"usf","name":"University of South Florida","base_url":"https://digitalcommons.usf.edu/do/oai/"},"display":{"title":"The Virtual Hip: An Anatomically Accurate Finite Element Model Based on the Visible Human Dataset","abstract":"The purpose of this study is to determine if element decimation of a 3-D anatomical model affects the results of Finite Element Analysis (FEA). FEA has been increasingly applied to the biological and medical sciences. In order for an anatomical model to successfully run in FEA, the 3-D model’s complex geometry must be simplified, resulting in a loss of anatomical detail. The process of decimation reduces the number of elements within the structure and creates a simpler approximation of the model. Using the National Library of Medicine’s Visible Human Male dataset, a virtual 3-D representation of several structures of the hip were produced. The initial highest resolution model was processed through several levels of decimation. Each of these representative anatomical models were run in COMSOL 3.5a to measure the degree of displacement. These results were compared against the original model to determine what level of error was introduced due to model simplification.","abstract_html":"The purpose of this study is to determine if element decimation of a 3-D anatomical model affects the results of Finite Element Analysis (FEA). FEA has been increasingly applied to the biological and medical sciences. In order for an anatomical model to successfully run in FEA, the 3-D model’s complex geometry must be simplified, resulting in a loss of anatomical detail. The process of decimation reduces the number of elements within the structure and creates a simpler approximation of the model. Using the National Library of Medicine’s Visible Human Male dataset, a virtual 3-D representation of several structures of the hip were produced. The initial highest resolution model was processed through several levels of decimation. Each of these representative anatomical models were run in COMSOL 3.5a to measure the degree of displacement. These results were compared against the original model to determine what level of error was introduced due to model simplification.","abstract_has_math":false,"creators":["Ford, Jonathan M."],"institution":"University of South Florida","degree_name":null,"degree_level":"Thesis","degree_discipline":"Chemical and Biomedical Engineering","degree_department":null,"school":null,"contributors":["Don Hilbelink, Ph.D.","Les Piegl, Ph.D.","William Lee III, Ph.D., P.E.","Karl Muffly, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-10-04T07:00:00Z","date_published":"2010-10-04T07:00:00Z","updated_at":"2026-11-19T08:38:08Z","subjects":["Quantitative Anatomy","Gluteus Minimus","COMSOL","Model Error","American Studies","Arts and Humanities","Biomedical Engineering and Bioengineering","Chemical Engineering"],"languages":["EN-US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.usf.edu/etd/3451","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.usf.edu/etd/3451","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.usf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.usf.edu%3Aetd-4646","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Don Hilbelink, Ph.D.","Les Piegl, Ph.D.","William Lee III, Ph.D., P.E.","Karl Muffly, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Ford, Jonathan M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-10-04T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical and Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis","M.Ch.E"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of South Florida"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Quantitative Anatomy","Gluteus Minimus","COMSOL","Model Error","American Studies","Arts and Humanities","Biomedical Engineering and Bioengineering","Chemical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["EN-US"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["default"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.usf.edu/etd/3451"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The purpose of this study is to determine if element decimation of a 3-D anatomical model affects the results of Finite Element Analysis (FEA). FEA has been increasingly applied to the biological and medical sciences. In order for an anatomical model to successfully run in FEA, the 3-D model’s complex geometry must be simplified, resulting in a loss of anatomical detail. The process of decimation reduces the number of elements within the structure and creates a simpler approximation of the model. Using the National Library of Medicine’s Visible Human Male dataset, a virtual 3-D representation of several structures of the hip were produced. The initial highest resolution model was processed through several levels of decimation. Each of these representative anatomical models were run in COMSOL 3.5a to measure the degree of displacement. These results were compared against the original model to determine what level of error was introduced due to model simplification."]},{"key":"dc:title","label":"Title","values":["The Virtual Hip: An Anatomically Accurate Finite Element Model Based on the Visible Human Dataset"]}]}],"canonical_facts":{"dc:contributor":["Don Hilbelink, Ph.D.","Les Piegl, Ph.D.","William Lee III, Ph.D., P.E.","Karl Muffly, Ph.D."],"dc:creator":["Ford, Jonathan M."],"dc:date":["2010-10-04T07:00:00Z"],"dc:description":["The purpose of this study is to determine if element decimation of a 3-D anatomical model affects the results of Finite Element Analysis (FEA). FEA has been increasingly applied to the biological and medical sciences. In order for an anatomical model to successfully run in FEA, the 3-D model’s complex geometry must be simplified, resulting in a loss of anatomical detail. The process of decimation reduces the number of elements within the structure and creates a simpler approximation of the model. Using the National Library of Medicine’s Visible Human Male dataset, a virtual 3-D representation of several structures of the hip were produced. The initial highest resolution model was processed through several levels of decimation. Each of these representative anatomical models were run in COMSOL 3.5a to measure the degree of displacement. These results were compared against the original model to determine what level of error was introduced due to model simplification."],"dc:identifier":["https://digitalcommons.usf.edu/etd/3451"],"dc:language":["EN-US"],"dc:rights.license":["default"],"dc:subject":["Quantitative Anatomy","Gluteus Minimus","COMSOL","Model Error","American Studies","Arts and Humanities","Biomedical Engineering and Bioengineering","Chemical Engineering"],"dc:title":["The Virtual Hip: An Anatomically Accurate Finite Element Model Based on the Visible Human Dataset"],"thesis:degree_discipline":["Chemical and Biomedical Engineering"],"thesis:degree_level":["Thesis","M.Ch.E"],"thesis:institution_name":["University of South Florida"]},"updated_at":"2026-11-19T08:38:08Z"}